Effects of modified abutment characteristics on peri-implant soft tissue health: A systematic review and meta-analysis

Ignacio Sanz-Martín, Ignacio Sanz-Sánchez, Ana Carrillo de Albornoz, Elena Figuero, Mariano Sanz, Ignacio Sanz-Martín, Ignacio Sanz-Sánchez, Ana Carrillo de Albornoz, Elena Figuero, Mariano Sanz

Abstract

Objectives: The purpose of this systematic review was to evaluate the impact of the abutment characteristics on peri-implant tissue health and to identify the most suitable material and surface characteristics.

Methods: A protocol was developed aimed to answer the following focused question: "Which is the effect of the modification of the abutment design in regard to the maintenance of the peri-implant soft tissue health?" Further subanalysis aimed to investigate the impact of the abutment material, macroscopic design, surface topography and surface manipulation. Randomised controlled trials (RCTs) with a follow-up of at least 6 months after implant loading were considered as inclusion criteria. Meta-analyses were performed whenever possible.

Results: Nineteen final publications from thirteen investigations were included. The results from the meta-analysis indicated that zirconia abutments (Zi) experienced less increase in BOP values over time [n = 3; WMD = -26.96; 95% CI (-45.00; -8.92); p = .003] and less plaque accumulation [n = 1; MD = -20.00; 95% CI (-41.47; 1.47); p = .068] when compared with titanium abutments (Ti). Bone loss was influenced by the method of abutment decontamination [n = 1; MD = -0.44; 95% CI (-0.65; -0.23); p < .001]. The rest of the studied outcomes did not show statistically significant differences.

Conclusions: The macroscopic design, the surface topography and the manipulation of the implant abutment did not have a significant influence on peri-implant inflammation. In contrast, the abutment material demonstrated increased BOP values over time for Ti when compared to Zi abutments.

Keywords: dental abutment; dental implants; dental-implant abutment surface; mucositis; systematic review.

© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Figures

Figure 1
Figure 1
Flow chart depicting the search strategy and selection process
Figure 2
Figure 2
Forest plots for the BOP meta‐analysis

References

    1. Abrahamsson, I. , Berglundh, T. , Wennstrom, J. , & Lindhe, J. (1996). The peri‐implant hard and soft tissues at different implant systems. A comparative study in the dog. Clinical Oral Implants Research, 7, 212–219.
    1. Abrahamsson, I. , Zitzmann, N. U. , Berglundh, T. , Linder, E. , Wennerberg, A. , & Lindhe, J. (2002). The mucosal attachment to titanium implants with different surface characteristics: An experimental study in dogs. Journal of Clinical Periodontology, 29, 448–455.
    1. Abrahamsson, I. , Zitzmann, N. U. , Berglundh, T. , Wennerberg, A. , & Lindhe, J. (2001). Bone and soft tissue integration to titanium implants with different surface topography: An experimental study in the dog. International Journal of Oral and Maxillofacial Implants, 16, 323–332.
    1. Andersson, B. , Glauser, R. , Maglione, M. , & Taylor, A. (2003). Ceramic implant abutments for short‐span fpds: A prospective 5‐year multicenter study. International Journal of Prosthodontics, 16, 640–646.
    1. Andersson, B. , Scharer, P. , Simion, M. , & Bergstrom, C. (1999). Ceramic implant abutments used for short‐span fixed partial dentures: A prospective 2‐year multicenter study. International Journal of Prosthodontics, 12, 318–324.
    1. Andersson, B. , Taylor, A. , Lang, B. R. , Scheller, H. , Scharer, P. , Sorensen, J. A. , & Tarnow, D. (2001). Alumina ceramic implant abutments used for single‐tooth replacement: A prospective 1‐ to 3‐year multicenter study. International Journal of Prosthodontics, 14, 432–438.
    1. Baldini, N. , D'Elia, C. , Clementini, M. , Carrillo de Albornoz, A. , Sanz, M. , & De Sanctis, M. (2016). Esthetic outcomes of single‐tooth implant‐supported restorations using metal‐ceramic restorations with zirconia or titanium abutments: A randomized controlled clinical study. International Journal of Periodontics & Restorative Dentistry, 36, e59–e66.
    1. Berglundh, T. , Abrahamsson, I. , & Lindhe, J. (2005). Bone reactions to longstanding functional load at implants: An experimental study in dogs. Journal of Clinical Periodontology, 32, 925–932.
    1. Berglundh, T. , Abrahamsson, I. , Welander, M. , Lang, N. P. , & Lindhe, J. (2007). Morphogenesis of the peri‐implant mucosa: An experimental study in dogs. Clinical Oral Implants Research, 18, 1–8.
    1. van Brakel, R. , Meijer, G. J. , Verhoeven, J. W. , Jansen, J. , de Putter, C. , & Cune, M. S. (2012). Soft tissue response to zirconia and titanium implant abutments: An in vivo within‐subject comparison. Journal of Clinical Periodontology, 39, 995–1001.
    1. van Brakel, R. , Noordmans, H. J. , Frenken, J. , de Roode, R. , de Wit, G. C. , & Cune, M. S. (2011). The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues. Clinical Oral Implants Research, 22, 1172–1178.
    1. Buser, D. , Janner, S. F. , Wittneben, J. G. , Bragger, U. , Ramseier, C. A. , & Salvi, G. E. (2012). 10‐year survival and success rates of 511 titanium implants with a sandblasted and acid‐etched surface: A retrospective study in 303 partially edentulous patients. Clinical Implant Dentistry and Related Research, 14, 839–851.
    1. Canullo, L. , Genova, T. , Tallarico, M. , Gautier, G. , Mussano, F. , & Botticelli, D. (2016). Plasma of argon affects the earliest biological response of different implant surfaces: An in vitro comparative study. Journal of Dental Research, 95, 566–573.
    1. Canullo, L. , Micarelli, C. , Lembo‐Fazio, L. , Iannello, G. , & Clementini, M. (2014). Microscopical and microbiologic characterization of customized titanium abutments after different cleaning procedures. Clinical Oral Implants Research, 25, 328–336.
    1. Canullo, L. , Penarrocha, D. , Clementini, M. , Iannello, G. , & Micarelli, C. (2015). Impact of plasma of argon cleaning treatment on implant abutments in patients with a history of periodontal disease and thin biotype: Radiographic results at 24‐month follow‐up of a rct. Clinical Oral Implants Research, 26, 8–14.
    1. Canullo, L. , Tallarico, M. , Penarrocha‐Oltra, D. , Monje, A. , Wang, H. L. , & Penarrocha‐Diago, M. (2016). Implant abutment cleaning by plasma of argon: 5‐year follow‐up of a randomized controlled trial. Journal of Periodontology, 87, 434–442.
    1. Carrillo de Albornoz, A. , Vignoletti, F. , Ferrantino, L. , Cardenas, E. , De Sanctis, M. , & Sanz, M. (2014). A randomized trial on the aesthetic outcomes of implant‐supported restorations with zirconia or titanium abutments. Journal of Clinical Periodontology, 41, 1161–1169.
    1. Cochran, W. G. (1954). The combination of estimates from different experiments. Biometrics, 10, 101–129.
    1. Coli, P. , Christiaens, V. , Sennerby, L. , & Bruyn, H. (2017). Reliability of periodontal diagnostic tools for monitoring peri‐implant health and disease. Periodontology 2000, 73, 203–217.
    1. Degidi, M. , Artese, L. , Scarano, A. , Perrotti, V. , Gehrke, P. , & Piattelli, A. (2006). Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri‐implant soft tissues around titanium and zirconium oxide healing caps. Journal of Periodontology, 77, 73–80.
    1. Derks, J. , Schaller, D. , Hakansson, J. , Wennstrom, J. L. , Tomasi, C. , & Berglundh, T. (2016). Peri‐implantitis – Onset and pattern of progression. Journal of Clinical Periodontology, 43, 383–388.
    1. DerSimonian, R. , & Laird, N. (1986). Meta‐analysis in clinical trials. Controlled Clinical Trials, 7, 177–188.
    1. Farina, R. , Filippi, M. , Brazzioli, J. , Tomasi, C. , & Trombelli, L. (2017). Bleeding on probing around dental implants: A retrospective study of associated factors. Journal of Clinical Periodontology, 44, 115–122.
    1. Fenner, N. , Hammerle, C. H. , Sailer, I. , & Jung, R. E. (2016). Long‐term clinical, technical, and esthetic outcomes of all‐ceramic vs. titanium abutments on implant supporting single‐tooth reconstructions after at least 5 years. Clinical Oral Implants Research, 27, 716–723.
    1. Gallucci, G. O. , Grutter, L. , Chuang, S. K. , & Belser, U. C. (2011). Dimensional changes of peri‐implant soft tissue over 2 years with single‐implant crowns in the anterior maxilla. Journal of Clinical Periodontology, 38, 293–299.
    1. Gallucci, G. O. , Grutter, L. , Nedir, R. , Bischof, M. , & Belser, U. C. (2011). Esthetic outcomes with porcelain‐fused‐to‐ceramic and all‐ceramic single‐implant crowns: A randomized clinical trial. Clinical Oral Implants Research, 22, 62–69.
    1. Garcia, B. , Camacho, F. , Penarrocha, D. , Tallarico, M. , Perez, S. , & Canullo, L. (2017). Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: A randomized controlled histologic study. Clinical Oral Implants Research. 28, 1269–1277.
    1. Gerber, J. A. , Tan, W. C. , Balmer, T. E. , Salvi, G. E. , & Lang, N. P. (2009). Bleeding on probing and pocket probing depth in relation to probing pressure and mucosal health around oral implants. Clinical Oral Implants Research, 20, 75–78.
    1. Glauser, R. , Schupbach, P. , Gottlow, J. , & Hammerle, C. H. (2005). Periimplant soft tissue barrier at experimental one‐piece mini‐implants with different surface topography in humans: A light‐microscopic overview and histometric analysis. Clinical Implant Dentistry and Related Research, 7(Suppl 1), S44–S51.
    1. Gotfredsen, K. (2012). A 10‐year prospective study of single tooth implants placed in the anterior maxilla. Clinical Implant Dentistry and Related Research, 14, 80–87.
    1. Hermann, J. S. , Jones, A. A. , Bakaeen, L. G. , Buser, D. , Schoolfield, J. D. , & Cochran, D. L. (2011). Influence of a machined collar on crestal bone changes around titanium implants: A histometric study in the canine mandible. Journal of Periodontology, 82, 1329–1338.
    1. Higgins J. P. T., & Green S. (2011). Cochrane handbook for systematic reviews of interventions version 5.1.0 [updated March 2011]. London: The Cochrane Collaboration; Retrieved from .
    1. Higgins, J. P. T. , Thompson, S. G. , Deeks, J. J. , & Altman, D. G. (2003). Measuring inconsistency in meta‐analyses. British Medical Journal, 327, 557–560.
    1. Hosseini, M. , Worsaae, N. , Schiodt, M. , & Gotfredsen, K. (2011). A 1‐year randomised controlled trial comparing zirconia versus metal‐ceramic implant supported single‐tooth restorations. European Journal of Oral Implantology, 4, 347–361.
    1. Iglhaut, G. , Becker, K. , Golubovic, V. , Schliephake, H. , & Mihatovic, I. (2013). The impact of dis‐/reconnection of laser microgrooved and machined implant abutments on soft‐ and hard‐tissue healing. Clinical Oral Implants Research, 24, 391–397.
    1. Iglhaut, G. , Schwarz, F. , Winter, R. R. , Mihatovic, I. , Stimmelmayr, M. , & Schliephake, H. (2014). Epithelial attachment and downgrowth on dental implant abutments–a comprehensive review. Journal of Esthetic and Restorative Dentistry, 26, 324–331.
    1. Jemt, T. (1997). Regeneration of gingival papillae after single‐implant treatment. International Journal of Periodontics & Restorative Dentistry, 17, 326–333.
    1. Jepsen, S. , Berglundh, T. , Genco, R. , Aass, A. M. , Demirel, K. , Derks, J. , … Zitzmann, N. U. (2015). Primary prevention of peri‐implantitis: Managing peri‐implant mucositis. Journal of Clinical Periodontology, 42(Suppl 16), S152–S157.
    1. Kim, S. , Oh, K. C. , Han, D. H. , Heo, S. J. , Ryu, I. C. , Kwon, J. H. , & Han, C. H. (2010). Influence of transmucosal designs of three one‐piece implant systems on early tissue responses: A histometric study in beagle dogs. International Journal of Oral and Maxillofacial Implants, 25, 309–314.
    1. Linkevicius, T. , & Vaitelis, J. (2015). The effect of zirconia or titanium as abutment material on soft peri‐implant tissues: A systematic review and meta‐analysis. Clinical Oral Implants Research, 26(Suppl 11), 139–147.
    1. Nakamura, K. , Kanno, T. , Milleding, P. , & Ortengren, U. (2010). Zirconia as a dental implant abutment material: A systematic review. International Journal of Prosthodontics, 23, 299–309.
    1. Needleman, I. G. (2002). A guide to systematic reviews. Journal of Clinical Periodontology, 29(Suppl 3), 6–9; discussion 37–38. Review.
    1. Nicu, E. A. , Van Assche, N. , Coucke, W. , Teughels, W. , & Quirynen, M. (2012). Rct comparing implants with turned and anodically oxidized surfaces: A pilot study, a 3‐year follow‐up. Journal of Clinical Periodontology, 39, 1183–1190.
    1. Nothdurft, F. P. , Fontana, D. , Ruppenthal, S. , May, A. , Aktas, C. , Mehraein, Y. , … Kaestner, L. (2015). Differential behavior of fibroblasts and epithelial cells on structured implant abutment materials: A comparison of materials and surface topographies. Clinical Implant Dentistry and Related Research, 17, 1237–1249.
    1. Patil, R. C. , den Hartog, L. , van Heereveld, C. , Jagdale, A. , Dilbaghi, A. , & Cune, M. S. (2014). Comparison of two different abutment designs on marginal bone loss and soft tissue development. International Journal of Oral and Maxillofacial Implants, 29, 675–681.
    1. Rimondini, L. , Cerroni, L. , Carrassi, A. , & Torricelli, P. (2002). Bacterial colonization of zirconia ceramic surfaces: An in vitro and in vivo study. International Journal of Oral and Maxillofacial Implants, 17, 793–798.
    1. Rompen, E. (2012). The impact of the type and configuration of abutments and their (repeated) removal on the attachment level and marginal bone. European Journal of Oral Implantology, 5(Suppl), S83–S90.
    1. Rompen, E. , Domken, O. , Degidi, M. , Pontes, A. E. , & Piattelli, A. (2006). The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: A literature review. Clinical Oral Implants Research, 17(Suppl 2), 55–67.
    1. Rowland, S. A. , Shalaby, S. W. , Latour, R. A. Jr , & von Recum, A. F. (1995). Effectiveness of cleaning surgical implants: Quantitative analysis of contaminant removal. Journal of Applied Biomaterials, 6, 1–7.
    1. Sailer, I. , Zembic, A. , Jung, R. E. , Siegenthaler, D. , Holderegger, C. , & Hammerle, C. H. (2009). Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single‐tooth implant reconstructions: Preliminary results at 1 year of function. Clinical Oral Implants Research, 20, 219–225.
    1. Salvi, G. E. , Bosshardt, D. D. , Lang, N. P. , Abrahamsson, I. , Berglundh, T. , Lindhe, J. , … Donos, N. (2015). Temporal sequence of hard and soft tissue healing around titanium dental implants. Periodontology 2000, 68, 135–152.
    1. Scarano, A. , Piattelli, M. , Caputi, S. , Favero, G. A. , & Piattelli, A. (2004). Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study. Journal of Periodontology, 75, 292–296.
    1. Schwarz, F. , Hegewald, A. , & Becker, J. (2014). Impact of implant‐abutment connection and positioning of the machined collar/microgap on crestal bone level changes: A systematic review. Clinical Oral Implants Research, 25, 417–425.
    1. Schwarz, F. , Mihatovic, I. , Becker, J. , Bormann, K. H. , Keeve, P. L. , & Friedmann, A. (2013). Histological evaluation of different abutments in the posterior maxilla and mandible: An experimental study in humans. Journal of Clinical Periodontology, 40, 807–815.
    1. Schwarz, F. , Sahm, N. , & Becker, J. (2012). Impact of the outcome of guided bone regeneration in dehiscence‐type defects on the long‐term stability of peri‐implant health: Clinical observations at 4 years. Clinical Oral Implants Research, 23, 191–196.
    1. Serino, G. , Turri, A. , & Lang, N. P. (2013). Probing at implants with peri‐implantitis and its relation to clinical peri‐implant bone loss. Clinical Oral Implants Research, 24, 91–95.
    1. Teughels, W. , Van Assche, N. , Sliepen, I. , & Quirynen, M. (2006). Effect of material characteristics and/or surface topography on biofilm development. Clinical Oral Implants Research, 17(Suppl 2), 68–81.
    1. Tobias, A. , & Campbell, M. J. (1999). Modelling influenza epidemics in the relation between black smoke and total mortality. A sensitivity analysis. Journal of Epidemiology and Community Health, 53, 583–584.
    1. Van Assche, N. , Coucke, W. , Teughels, W. , Naert, I. , Cardoso, M. V. , & Quirynen, M. (2012). Rct comparing minimally with moderately rough implants. Part 1: Clinical observations. Clinical Oral Implants Research, 23, 617–624.
    1. Weinlander, M. , Lekovic, V. , Spadijer‐Gostovic, S. , Milicic, B. , Wegscheider, W. A. , & Piehslinger, E. (2011). Soft tissue development around abutments with a circular macro‐groove in healed sites of partially edentulous posterior maxillae and mandibles: A clinical pilot study. Clinical Oral Implants Research, 22, 743–752.
    1. Welander, M. , Abrahamsson, I. , & Berglundh, T. (2008). The mucosal barrier at implant abutments of different materials. Clinical Oral Implants Research, 19, 635–641.
    1. Wittneben, J. G. , Gavric, J. , Belser, U. C. , Bornstein, M. M. , Joda, T. , Chappuis, V. , … Bragger, U. (2017). Esthetic and clinical performance of implant‐supported all‐ceramic crowns made with prefabricated or cad/cam zirconia abutments. Journal of Dental Research, 96, 163–170.
    1. Zembic, A. , Bosch, A. , Jung, R. E. , Hammerle, C. H. , & Sailer, I. (2013). Five‐year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single‐implant crowns in canine and posterior regions. Clinical Oral Implants Research, 24, 384–390.
    1. Zembic, A. , Sailer, I. , Jung, R. E. , & Hammerle, C. H. (2009). Randomized‐controlled clinical trial of customized zirconia and titanium implant abutments for single‐tooth implants in canine and posterior regions: 3‐year results. Clinical Oral Implants Research, 20, 802–808.

Source: PubMed