Chronic effects of air pollution on lung function after lung transplantation in the Systems prediction of Chronic Lung Allograft Dysfunction (SysCLAD) study

Meriem Benmerad, Rémy Slama, Karine Botturi, Johanna Claustre, Antoine Roux, Edouard Sage, Martine Reynaud-Gaubert, Carine Gomez, Romain Kessler, Olivier Brugière, Jean-François Mornex, Sacha Mussot, Marcel Dahan, Véronique Boussaud, Isabelle Danner-Boucher, Claire Dromer, Christiane Knoop, Annick Auffray, Johanna Lepeule, Laure Malherbe, Frederik Meleux, Laurent Nicod, Antoine Magnan, Christophe Pison, Valérie Siroux, SysCLAD consortium, Meriem Benmerad, Rémy Slama, Karine Botturi, Johanna Claustre, Antoine Roux, Edouard Sage, Martine Reynaud-Gaubert, Carine Gomez, Romain Kessler, Olivier Brugière, Jean-François Mornex, Sacha Mussot, Marcel Dahan, Véronique Boussaud, Isabelle Danner-Boucher, Claire Dromer, Christiane Knoop, Annick Auffray, Johanna Lepeule, Laure Malherbe, Frederik Meleux, Laurent Nicod, Antoine Magnan, Christophe Pison, Valérie Siroux, SysCLAD consortium

Abstract

An irreversible loss in lung function limits the long-term success in lung transplantation. We evaluated the role of chronic exposure to ambient air pollution on lung function levels in lung transplant recipients (LTRs).The lung function of 520 LTRs from the Cohort in Lung Transplantation (COLT) study was measured every 6 months. The levels of air pollutants (nitrogen dioxide (NO2), particulate matter with an aerodynamic cut-off diameter of x µm (PMx) and ozone (O3)) at the patients' home address were averaged in the 12 months before each spirometry test. The effects of air pollutants on forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) in % predicted were estimated using mixed linear regressions. We assessed the effect modification of macrolide antibiotics in this relationship.Increased 12-month levels of pollutants were associated with lower levels of FVC % pred (-2.56%, 95% CI -3.86--1.25 for 5 µg·m-3 of PM10; -0.75%, 95% CI -1.38--0.12 for 2 µg·m-3 of PM2.5 and -2.58%, 95% CI -4.63--0.53 for 10 µg·m-3 of NO2). In patients not taking macrolides, the deleterious association between PM and FVC tended to be stronger and PM10 was associated with lower FEV1Our study suggests a deleterious effect of chronic exposure to air pollutants on lung function levels in LTRs, which might be modified with macrolides.

Trial registration: ClinicalTrials.gov NCT00980967.

Copyright ©ERS 2017.

Source: PubMed

3
Iratkozz fel