The different role of each head of the triceps brachii muscle in elbow extension

Erica Kholinne, Rizki Fajar Zulkarnain, Yu Cheng Sun, SungJoon Lim, Jae-Myeung Chun, In-Ho Jeon, Erica Kholinne, Rizki Fajar Zulkarnain, Yu Cheng Sun, SungJoon Lim, Jae-Myeung Chun, In-Ho Jeon

Abstract

Objective: The aim of this study was to investigate the functional role of each head of the triceps brachii muscle, depending on the angle of shoulder elevation, and to compare each muscle force and activity by using a virtual biomechanical simulator and surface electromyography.

Methods: Ten healthy participants (8 males and 2 females) were included in this study. The mean age was 29.2 years (23-45). Each participant performed elbow extension tasks in five different degrees (0, 45, 90, 135, and 180°) of shoulder elevation with three repetitions. Kinematics data and surface electromyography signal of each head of the triceps brachii were recorded. Recorded kinematics data were then applied to an inverse kinematics musculoskeletal modeling software function (OpenSim) to analyze the triceps brachii's muscle force. Correlation between muscle force, muscle activity, elbow extension, and shoulder elevation angle were compared and analyzed for each head of triceps brachii.

Results: At 0° shoulder elevation, the long head of the triceps brachii generates a significantly higher muscle force and muscle activation than the lateral and medial heads (p < 0.05). While at 90°, 135° and 180° shoulder elevation, the medial head of the triceps brachii showed a significantly higher muscle force than the long and the lateral heads (p < 0.05).

Conclusions: Each head of the triceps brachii has a different pattern of force and activity during different shoulder elevations. The long head contributes to elbow extension more at shoulder elevation and the medial head takes over at 90° and above of shoulder elevation. This study provides further understanding of triceps brachii's for clinicians and health trainers who need to investigate the functional role of the triceps brachii in detail.

Keywords: Elbow extension; Motion analysis; OpenSim; Triceps brachii; sEMG.

Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

Figures

Fig. 1
Fig. 1
Elbow extension task simulation on OpenSim interface for A. 0°; B. 45°; C. 90°; D. 135°; and E. 180° shoulder elevation.
Fig. 2
Fig. 2
Surface Electromyography Electrode and Accelerometer placement on the three heads of the TB muscle for posterior right upper extremity; A. Long Head; B. Lateral Head; C. Medial Head; D. Ground Reference; E. Accelerometer.
Fig. 3
Fig. 3
Muscle force and muscle activation, from left to right, of the long head, lateral head, and medial head in active elbow extension movement. The muscle force and activation of the long head and medial head differed from each other depending on the elbow joint angle and shoulder elevation angle. Muscle force and activation of the lateral head was similar to the medial head, albeit significantly lower.

References

    1. Ali A., Sundaraj K., Badlishah Ahmad R., Ahamed N.U., Islam A., Sundaraj S. Muscle fatigue in the three heads of the triceps brachii during a controlled forceful hand grip task with full elbow extension using surface electromyography. J Hum Kinet. 2015;46:69–76.
    1. Ali M.A., Sundaraj K., Ahmad R.B., Ahamed N.U., Islam M.A., Sundaraj S. Evaluation of repetitive isometric contractions on the heads of triceps brachii muscle during grip force exercise. Technol Health Care. 2014;22:617–625.
    1. Bilodeau M., Schindler-Ivens S., Williams D.M., Chandran R., Sharma S.S. EMG frequency content changes with increasing force and during fatigue in the quadriceps femoris muscle of men and women. J Electromyogr Kinesiol. 2003;13:83–92.
    1. Carius D., Kugler P., Kuhwald H.M., Wollny R. Absolute and relative intrasession reliability of surface EMG variables for voluntary precise forearm movements. J Electromyogr Kinesiol. 2015;25:860–869.
    1. Delp S.L., Anderson F.C., Arnold A.S. OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng. 2007;54:1940–1950.
    1. Ewing K.A., Fernandez J.W., Begg R.K., Galea M.P., Lee P.V. Prophylactic knee bracing alters lower-limb muscle forces during a double-leg drop landing. J Biomech. 2016
    1. Gerbeaux M., Turpin E., Lensel-Corbeil G. Musculo-articular modelling of the triceps brachii. J Biomech. 1996;29:171–180.
    1. Gerdle B., Henriksson-Larsen K., Lorentzon R., Wretling M.L. Dependence of the mean power frequency of the electromyogram on muscle force and fibre type. Acta Physiol Scand. 1991;142:457–465.
    1. Gerrand C. Extensile exposure. BMJ Br Med J. 2007;334:1277.
    1. Gordon A.M., Huxley A.F., Julian F.J. The variation in isometric tension with sarcomere length in vertebrate muscle fibres. J Physiol. 1966;184:170–192.
    1. Hermens H.J. Roessingh Research and Development; [Pays-Bas]: 1999. Commission des Communautés ee, Biomedical, Health Research P. SENIAM : European recommendations for surface electromyography : results of the SENIAM project. (ISBN No. 9075452152 9789075452150)
    1. Hoenecke H.R., Jr., Flores-Hernandez C., D'Lima D.D. Reverse total shoulder arthroplasty component center of rotation affects muscle function. J Shoulder Elbow Surg. 2014;23:1128–1135.
    1. Holloway C.S., Symonds A., Suzuki T., Gall A., Smitham P., Taylor S. Vol. 2015. 2015. Linking wheelchair kinetics to glenohumeral joint demand during everyday accessibility activities; pp. 2478–2481. (Conference proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society IEEE Engineering in Medicine and Biology Society Annual Conference).
    1. Holzbaur K.R., Murray W.M., Delp S.L. A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control. Ann Biomed Eng. 2005;33:829–840.
    1. Lee J.H., Asakawa D.S., Dennerlein J.T., Jindrich D.L. Extrinsic and intrinsic index finger muscle attachments in an OpenSim upper-extremity model. Ann Biomed Eng. 2015;43:937–948.
    1. Lerner Z.F., Browning R.C. Compressive and shear hip joint contact forces are affected by pediatric obesity during walking. J Biomech. 2016;49:1547–1553.
    1. Madsen M., Marx R.G., Millett P.J., Rodeo S.A., Sperling J.W., Warren R.F. Surgical anatomy of the triceps brachii tendon: anatomical study and clinical correlation. Am J Sports Med. 2006;34:1839–1843.
    1. Meireles S., De Groote F., Reeves N.D. Knee contact forces are not altered in early knee osteoarthritis. Gait Posture. 2016;45:115–120.
    1. Modenese L., Phillips A.T., Bull A.M. An open source lower limb model: hip joint validation. J Biomech. 2011;44:2185–2193.
    1. Moore K.L., Dalley A.F., Agur A.M.R. (ISBN No. 1451119453 9781451119459 9781451184471 1451184476) Clin Oriented Anat. 2014;35:19–26.
    1. Murray W.M., Buchanan T.S., Delp S.L. Scaling of peak moment arms of elbow muscles with upper extremity bone dimensions. J Biomech. 2002;35:19–26.
    1. Onishi H., Yagi R., Akasaka K., Momose K., Ihashi K., Handa Y. Relationship between EMG signals and force in human vastus lateralis muscle using multiple bipolar wire electrodes. J Electromyogr Kinesiol. 2000 Feb;10(1):59–67.
    1. Parson S.H. Clinically oriented anatomy, 6th edn. J Anat. 2009;215:474.
    1. van Riet R.P., Morrey B.F., Ho E., O'Driscoll S.W. Surgical treatment of distal triceps ruptures. J Bone Joint Surg Am. 2003;85:1961–1967.

Source: PubMed

3
Iratkozz fel