Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness

George A Mashour, Kevin K Tremper, Michael S Avidan, George A Mashour, Kevin K Tremper, Michael S Avidan

Abstract

Background: The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one case of awareness in the high-risk population was 138. Since the number needed to treat and the associated cost of treatment would be much higher in the general population, the efficacy of the Bispectral Index monitor in preventing awareness in all anesthetized patients needs to be clearly established. This is especially true given the findings of the B-Unaware trial, which demonstrated no significant difference between protocols based on the Bispectral Index monitor or minimum alveolar concentration for the reduction of awareness in high risk patients.

Methods/design: To evaluate efficacy in the general population, we are conducting a prospective, randomized, controlled trial comparing the Bispectral Index monitor to a non-electroencephalographic gauge of anesthetic depth. The total recruitment for the study is targeted for 30,000 patients at both low and high risk for awareness. We have developed a novel algorithm that is capable of real-time analysis of our electronic perioperative information system. In one arm of the study, anesthesia providers will receive an electronic page if the Bispectral Index value is >60. In the other arm of the study, anesthesia providers will receive a page if the age-adjusted minimum alveolar concentration is <0.5. Our minimum alveolar concentration algorithm is sensitive to both inhalational anesthetics and intravenous sedative-hypnotic agents.

Discussion: Awareness during general anesthesia is a persistent problem and the role of the Bispectral Index monitor in its prevention is still unclear. The Michigan Awareness Control Study is the largest prospective trial of awareness prevention ever conducted.

Trial registration: Clinical Trial NCT00689091.

References

    1. Joint Commission on Accreditation of Healthcare Organizations Preventing, and managing the impact of, anesthesia awareness. Jt Comm Perspect. 2004;24:10–11.
    1. Sebel PS, Bowdle TA, Ghoneim MM, Rampil IJ, Padilla RE, Gan TJ, Domino KB. The incidence of awareness during anesthesia: a multicenter United States study. Anesth Analg. 2004;99:833–839. doi: 10.1213/01.ANE.0000130261.90896.6C.
    1. Sandin RH, Enlund G, Samuelsson P, Lennmarken C. Awareness during anaesthesia: a prospective case study. Lancet. 2000;355:707–711. doi: 10.1016/S0140-6736(99)11010-9.
    1. Osterman JE, Kolk BA van der. Awareness during anesthesia and posttraumatic stress disorder. Gen Hosp Psychiatry. 1998;20:274–281. doi: 10.1016/S0163-8343(98)00035-8.
    1. Samuelsson P, Brudin L, Sandin RH. Late psychological symptoms after awareness among consecutively included surgical patients. Anesthesiology. 2007;106:26–32. doi: 10.1097/00000542-200701000-00009.
    1. Rosow C, Manberg PJ. Bispectral index monitoring. Anesthesiol Clin North America. 2001;19:947–966.
    1. Mashour GA. Monitoring consciousness: EEG-based measures of anesthetic depth. Seminars in Anesthesia, Perioperative Medicine and Pain. 2006;25:205–210. doi: 10.1053/j.sane.2006.09.007.
    1. Glass PS, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P. Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology. 1997;86:836–847. doi: 10.1097/00000542-199704000-00014.
    1. Kearse LA, Jr, Rosow C, Zaslavsky A, Connors P, Dershwitz M, Denman W. Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis. Anesthesiology. 1998;88:25–34. doi: 10.1097/00000542-199801000-00007.
    1. Ekman A, Lindholm ML, Lennmarken C, Sandin R. Reduction in the incidence of awareness using BIS monitoring. Acta Anaesthesiol Scand. 2004;48:20–26. doi: 10.1111/j.1399-6576.2004.00260.x.
    1. Myles PS, Leslie K, McNeil J, Forbes A, Chan MT. Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet. 2004;363:1757–1763. doi: 10.1016/S0140-6736(04)16300-9.
    1. Avidan MS, Zhang L, Burnside BA, Finkel KJ, Searleman AC, Selvidge JA, Saager L, Turner MS, Rao S, Bottros M, et al. Anesthesia awareness and the bispectral index. N Engl J Med. 2008;358:1097–1108. doi: 10.1056/NEJMoa0707361.
    1. Brice DD, Hetherington RR, Utting JE. A simple study of awareness and dreaming during anaesthesia. Br J Anaesth. 1970;42:535–542. doi: 10.1093/bja/42.6.535.
    1. Mashour GA, Esaki RK, Tremper KK, Glick DB, O'Connor M, Avidan MS. A novel classification instrument for intraoperative awareness events. Anesth Analg.
    1. Ghoneim MM, Block R, Haffarnan M, Mathews M. Awareness during anesthesia: risk factors, causes and sequelae: a review of reported cases in the literature. Anesth Analg. 2009;108:527–535. doi: 10.1213/ane.0b013e318193c634.
    1. Nickalls RWD, Mapleson WW. Age-related iso-MAC charts for isoflurane, sevoflurane and desflurane in man. Br J Anaesth. 2003;91:170–174. doi: 10.1093/bja/aeg132.
    1. Dwyer R, Bennett HL, Eger EI, Heilbron D. Effects of isoflurane and nitrous oxide in subanesthetic concentrations on memory and responsiveness in volunteers. Anesthesiology. 1992;77:888–898. doi: 10.1097/00000542-199211000-00009.
    1. Mashour GA, Esaki RK, Vandervest JC, Shanks A, Kheterpal S. A novel electronic algorithm for detecting potentially insufficient anesthesia: implications for the prevention of intraoperative awareness. J Clin Monit Comput. 2009;23:273–277. doi: 10.1007/s10877-009-9193-9.
    1. Aantaa R, Jaakola ML, Kallio A, Kanto J. Reduction of the minimum alveolar concentration of isoflurane by dexmedetomidine. Anesthesiology. 1997;86:1055–1060. doi: 10.1097/00000542-199705000-00008.
    1. Eger EI. Age, minimum alveolar anesthetic concentration, and minimum alveolar anesthetic concentration-awake. Anesth Analg. 2001;93:947–953. doi: 10.1097/00000539-200110000-00029.

Source: PubMed

3
Iratkozz fel