Randomized, double-blinded, placebo-controlled trial evaluating simethicone pretreatment with bowel preparation during colonoscopy

Mohit Rishi, Jaskarin Kaur, Mark Ulanja, Nicholas Manasewitsch, Molly Svendsen, Abubaker Abdalla, Shashank Vemala, Julie Kewanyama, Karmjit Singh, Nirmal Singh, Nageshwara Gullapalli, Eric Osgard, Mohit Rishi, Jaskarin Kaur, Mark Ulanja, Nicholas Manasewitsch, Molly Svendsen, Abubaker Abdalla, Shashank Vemala, Julie Kewanyama, Karmjit Singh, Nirmal Singh, Nageshwara Gullapalli, Eric Osgard

Abstract

Background: The presence of small air bubbles and foam are an impediment to a successful colonoscopy. They impair an endoscopist's view and diminish the diagnostic accuracy of the study. This has been particularly noted to be of concern with the switch to lower volume polyethylene glycol (PEG) and bisacodyl combination preparation.

Aim: To evaluate the effect of oral simethicone addition to bowel preparation on intraluminal bubbles reduction during colonoscopy.

Methods: Described is a prospective, randomized, multi-center, double-blinded, placebo-controlled study to evaluate the use of premixed simethicone formulation with split-regimen, low-volume PEG-bisacodyl combination bowel preparation for 168 outpatients undergoing screening, surveillance, and diagnostic colonoscopies. Primary outcome includes evaluation of bubbles during colonoscopy graded using the Intraluminal Bubbles Scale. Secondary outcomes include evaluation of the Boston Bowel Preparation Scale (BBPS), total number of polyps, polyp size differentiation, polyp laterality, adenoma detection, mass detection, cecal insertion time, withdrawal time, and patient-reported adverse events.

Results: Higher Intraluminal Bubbles grades III and IV (less than 75% of the mucosa cleared of bubbles/foam requiring intervention with simethicone infused wash) were detected in the placebo group [Simethicone n = 4/84 vs Placebo n = 20/84 (P = 0.007)]. BBPS total score was 7.42 [standard deviation (SD) = ± 1.51] in the simethicone group and 7.28 (SD = ± 1.44) in the placebo group (P = 0.542) from a total of 9. Significantly higher number of adenomas were detected in the simethicone group (P = 0.001).

Conclusion: The addition of simethicone to bowel preparation is well advised for its anti-foaming properties. The results of this study suggest that addition of oral simethicone can improve bowel wall visibility.

Keywords: Adenoma detection; Colonoscopy; Intraluminal bubbles; Simethicone.

Conflict of interest statement

Conflict-of-interest statement: None of the participating authors have any conflicts of interest to declare.

Figures

Figure 1
Figure 1
Patient disposition.

References

    1. Wexner SD, Beck DE, Baron TH, Fanelli RD, Hyman N, Shen B, Wasco KE American Society of Colon and Rectal Surgeons; American Society for Gastrointestinal Endoscopy; Society of American Gastrointestinal and Endoscopic Surgeons. A consensus document on bowel preparation before colonoscopy: prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) Gastrointest Endosc. 2006;63:894–909.
    1. Harrison NM, Hjelkrem MC. Bowel cleansing before colonoscopy: Balancing efficacy, safety, cost and patient tolerance. World J Gastrointest Endosc. 2016;8:4–12.
    1. Toledo TK, DiPalma JA. Review article: colon cleansing preparation for gastrointestinal procedures. Aliment Pharmacol Ther. 2001;15:605–611.
    1. da Silva MM, Briars GL, Patrick MK, Cleghorn GJ, Shepherd RW. Colonoscopy preparation in children: safety, efficacy, and tolerance of high- versus low-volume cleansing methods. J Pediatr Gastroenterol Nutr. 1997;24:33–37.
    1. Adams WJ, Meagher AP, Lubowski DZ, King DW. Bisacodyl reduces the volume of polyethylene glycol solution required for bowel preparation. Dis Colon Rectum. 1994;37:229–33; discussion 233-4.
    1. Kojecky V, Matous J, Keil R, Dastych M, Kroupa R, Zadorova Z, Varga M, Dolina J, Kment M, Hep A. A head-to-head comparison of 4-L polyethylene glycol and low-volume solutions before colonoscopy: which is the best? A multicentre, randomized trial. Int J Colorectal Dis. 2017;32:1763–1766.
    1. Brecević L, Bosan-Kilibarda I, Strajnar F. Mechanism of antifoaming action of simethicone. J Appl Toxicol. 1994;14:207–211.
    1. Tongprasert S, Sobhonslidsuk A, Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol. 2009;15:3032–3037.
    1. Ofstead CL, Wetzler HP, Johnson EA, Heymann OL, Maust TJ, Shaw MJ. Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing. Am J Infect Control. 2016;44:1237–1240.
    1. Yoo IK, Jeen YT, Kang SH, Lee JH, Kim SH, Lee JM, Choi HS, Kim ES, Keum B, Chun HJ, Lee HS, Kim CD. Improving of bowel cleansing effect for polyethylene glycol with ascorbic acid using simethicone: A randomized controlled trial. Medicine (Baltimore) 2016;95:e4163.
    1. Matro R, Tupchong K, Daskalakis C, Gordon V, Katz L, Kastenberg D. The effect on colon visualization during colonoscopy of the addition of simethicone to polyethylene glycol-electrolyte solution: a randomized single-blind study. Clin Transl Gastroenterol. 2012;3:e26.
    1. Lai EJ, Calderwood AH, Doros G, Fix OK, Jacobson BC. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625.
    1. Parente F, Vailati C, Bargiggia S, Manes G, Fontana P, Masci E, Arena M, Spinzi G, Baccarin A, Mazzoleni G, Testoni PA. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation. Dig Liver Dis. 2015;47:857–863.
    1. Repici A, Cestari R, Annese V, Biscaglia G, Vitetta E, Minelli L, Trallori G, Orselli S, Andriulli A, Hassan C. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations. Aliment Pharmacol Ther. 2012;36:717–724.
    1. Bai Y, Fang J, Zhao SB, Wang D, Li YQ, Shi RH, Sun ZQ, Sun MJ, Ji F, Si JM, Li ZS. Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial. Endoscopy. 2018;50:128–136.
    1. Alexander W. The uphill path to successful clinical trials: keeping patients enrolled. P T. 2013;38:225–227.
    1. Sakpal TV. Sample size estimation in clinical trial. Perspect Clin Res. 2010;1:67–69.
    1. Cohen J. A Coefficient of Agreement for Nominal Scales. Educ Psychol Meas. 1960;20:37–46.
    1. Rex DK, Petrini JL, Baron TH, Chak A, Cohen J, Deal SE, Hoffman B, Jacobson BC, Mergener K, Petersen BT, Safdi MA, Faigel DO, Pike IM ASGE/ACG Taskforce on Quality in Endoscopy. Quality indicators for colonoscopy. Am J Gastroenterol. 2006;101:873–885.
    1. Zhang S, Zheng D, Wang J, Wu J, Lei P, Luo Q, Wang L, Zhang B, Wang H, Cui Y, Chen M. Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial. Endoscopy. 2018;50:412–422.
    1. Pontone S, Angelini R, Standoli M, Patrizi G, Culasso F, Pontone P, Redler A. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695.
    1. Kump P, Hassan C, Spada C, Brownstone E, Datz C, Haefner M, Renner F, Schoefl R, Schreiber F. Efficacy and safety of a new low-volume PEG with citrate and simethicone bowel preparation for colonoscopy (Clensia): a multicenter randomized observer-blind clinical trial vs. a low-volume PEG with ascorbic acid (PEG-ASC) Endosc Int Open. 2018;6:E907–E913.
    1. de Leone A, Tamayo D, Fiori G, Ravizza D, Trovato C, De Roberto G, Fazzini L, Dal Fante M, Crosta C. Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy. World J Gastrointest Endosc. 2013;5:433–439.
    1. Barakat MT, Huang RJ, Banerjee S. Simethicone is retained in endoscopes despite reprocessing: impact of its use on working channel fluid retention and adenosine triphosphate bioluminescence values (with video) Gastrointest Endosc. 2019;89:115–123.
    1. Alagappan M, Brown JRG, Mori Y, Berzin TM. Artificial intelligence in gastrointestinal endoscopy: The future is almost here. World J Gastrointest Endosc. 2018;10:239–249.
    1. Wang Y, Tavanapong W, Wong J, Oh JH, de Groen PC. Polyp-Alert: near real-time feedback during colonoscopy. Comput Methods Programs Biomed. 2015;120:164–179.
    1. Yeh JH, Hsu MH, Tseng CM, Chen TH, Huang RY, Lee CT, Lin CW, Wang WL. The benefit of adding oral simethicone in bowel preparation regimen for the detection of colon adenoma: A systematic review and meta-analysis. J Gastroenterol Hepatol. 2019;34:830–836.
    1. Pan P, Zhao SB, Li BH, Meng QQ, Yao J, Wang D, Li ZS, Bai Y. Effect of supplemental simethicone for bowel preparation on adenoma detection during colonoscopy: A meta-analysis of randomized controlled trials. J Gastroenterol Hepatol. 2019;34:314–320.

Source: PubMed

3
Iratkozz fel