- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT01097967
Sleep Disordered Breathing in Transient Ischemic Attack (TIA)/Ischemic Stroke and Continuous Positive Airway Pressure (CPAP) Treatment Efficacy (SAS-CARE)
Sleep Disordered Breathing in TIA/Ischemic Stroke: Effects on Short- and Long-term Outcome and CPAP Treatment Efficacy: an Open, Observational, Clinical, Multicentre Trial With a Randomized Arm
Panoramica dello studio
Descrizione dettagliata
Sleep disordered breathing is an independent risk factor for cardiovascular morbidity and mortality and is frequent in patients with acute cerebrovascular events. In this study the investigators observe the association between sleep disordered breathing, hypertension, stroke and the evolution of blood markers for atherosclerosis as well as the efficacy of Continuous Positive Airway Pressure treatment in patients with acute or subacute cerebrovascular events.
Sleep disordered breathing is an independent risk factor for cardiovascular morbidity and mortality and is frequent in patients with acute cerebrovascular events. In this study the investigators observe the association between sleep disordered breathing, hypertension, stroke and the evolution of blood markers for atherosclerosis as well as the efficacy of Continuous Positive Airway Pressure treatment in patients with acute or subacute cerebrovascular events.
The SAS CARE 1 study is planned to verify whether or not sleep disordered breathing has a detrimental 3 months effect on cardiovascular functions and markers after acute cerebrovascular events. The SAS CARE 2 study is designed to address whether or not the treatment of sleep disordered breathing with CPAP reduces the combined rate of mortality, stroke, cardiovascular events (myocardial infarction/revascularisation/instable angina/ hospitalisation for heart insufficiency) over a 24 months period in patients after acute cerebrovascular events.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Fase 4
Contatti e Sedi
Luoghi di studio
-
-
-
Münster, Germania
- University Hospital Münster
-
-
-
-
Lombardia
-
Milan, Lombardia, Italia, I-20162
- Dipartimento Neuroscienze, Ospedale Niguarda
-
-
-
-
-
Bern, Svizzera, CH-3010
- Inselspital, Universitätsklinik für Pneumologie
-
-
Ticino
-
Bellinzona, Ticino, Svizzera, CH-6500
- Ospedale San Giovanni
-
Lugano, Ticino, Svizzera, CH-6900
- Neurocenter of Southern Switzerland, Ospedale Civico
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- ≥ 35 years old and < 75 years old
- with clinical diagnosis of TIA or ischemic stroke
- admitted in a Stroke Unit within 2 days from onset of symptoms
- or with TIA or ischemic stroke within the last 60-90 days
- signed Informed Consent
Exclusion Criteria:
- with unstable clinical situation (cardio-respiratory or life-threatening medical conditions)
- currently on CPAP or on CPAP during the last 3 months before stroke
- with non-ischemic events (intracerebral/subarachnoid haemorrhage)
- Patients with coma/stupor
- with borderline obstructive SDB (AHI 10-19)
- with any condition that interferes with the acceptance of CPAP treatment
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Prevenzione
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: CPAP in sleepy patients with SDB
SDB defined as AHI >=20 Sleepy defined as Epworth Sleepiness Score >=10
|
|
|
Nessun intervento: no CPAP in non sleepy patients with SDB
SDB defined as AHI >=20 Sleepy defined as Epworth Sleepiness Score >=10
|
|
|
Comparatore attivo: CPAP in non sleepy patients with SDB
SDB defined as AHI >=20 Sleepy defined as Epworth Sleepiness Score >=10
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Occurence of new vascular events or death in stroke survivors (myocardial infarction, stroke, death) assessed by telephone or reported
Lasso di tempo: 24 monts after stroke
|
New vascular events will be assessed by regular telephone interviews at 6,12 and 24 months after stroke
|
24 monts after stroke
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
CPAP-Compliance measured by hours of usage
Lasso di tempo: up to 24 months after stroke
|
Compliance is monitored for the use of the CPAP by the pulmonary specialist at the patients' routine visits 2-3, 4-6 weeks, 3-6 months, 12 and 24 months after randomisation.
The hours ofuse are registered by a chip inserted in the device.
Good compliance is, if the device was used > 10 hours per day.
Satisfactory compliance is defined for a use of the CPAP for at least 4 hours per night during at least 70% of the nights.
Insufficient compliance is defined as < 4 hours per night or less than 70% of nights.
|
up to 24 months after stroke
|
|
Blood pressure profile (systolic mean, diastolic mean, max, min: general, day, night) measured in mmHg for every patient by ambulatory 24h-BP-devices in the acute stroke phase, after 3 months and after 12 months
Lasso di tempo: up to 12 months after stroke
|
Mean systolic and diastolic BP values, minimal and maximum values will be calculated for each patient for each period of time [after stroke: whole measuring period, (36 h) first night, second day, and second night after stroke; 3 months after stroke: whole period (24 h), day, night].
In addition same measurements will be made 12 months after stroke The occurrence of dippers will be registered at baseline (after stroke) and at 3 months.
A dipper is defined, if the mean pressure at night is diminished more than 10% (compared to day data).
An inverse-dipper is defined if more than 10% augmentation of night pressure will be registered.
A deep-deeper is defined the mean pressure at night is diminished more than 20% (compared to day data).
|
up to 12 months after stroke
|
|
Blood pressure dipping measured by ambulatory 24h-BP-devices in the acute stroke phase, after 3 months and after 12 months
Lasso di tempo: up to 12 months after stroke
|
The occurrence of dippers will be registered at baseline (after stroke) and at 3 months and 12 months after stroke.
A dipper is defined, if the mean pressure at night is diminished more than 10% (compared to day data).
An inverse-dipper is defined if more than 10% augmentation of night pressure will be registered.
A deep-deeper is defined the mean pressure at night is diminished more than 20% (compared to day data).
|
up to 12 months after stroke
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Claudio Bassetti, Professor, Universitätsspital Bern (Inselspital) und Universität Bern
- Cattedra di studio: Carlo Cereda, Capo CLinica, Neurocentre of Southern Switzerland, Ospedale Civico
- Cattedra di studio: Sebastian Ott, MD, Pneumology, University Hospital, Bern
- Cattedra di studio: Lino Nobili, Prof. MD, Neurology, Stroke Unit, Ospedale Niguarda, Milan, Italy
- Cattedra di studio: Mauro Manconi, MD, Neurocentre of Southern Switzerland, Ospedale Civico
- Cattedra di studio: Peter Young, Prof. MD, Universitätsklinik Münster, Zentrum für Schlafmedizin
Pubblicazioni e link utili
Pubblicazioni generali
- Marin JM, Carrizo SJ, Vicente E, Agusti AG. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. 2005 Mar 19-25;365(9464):1046-53. doi: 10.1016/S0140-6736(05)71141-7.
- Martinez-Garcia MA, Soler-Cataluna JJ, Ejarque-Martinez L, Soriano Y, Roman-Sanchez P, Illa FB, Canal JM, Duran-Cantolla J. Continuous positive airway pressure treatment reduces mortality in patients with ischemic stroke and obstructive sleep apnea: a 5-year follow-up study. Am J Respir Crit Care Med. 2009 Jul 1;180(1):36-41. doi: 10.1164/rccm.200808-1341OC. Epub 2009 Apr 30.
- Bassetti C, Aldrich MS, Chervin RD, Quint D. Sleep apnea in patients with transient ischemic attack and stroke: a prospective study of 59 patients. Neurology. 1996 Nov;47(5):1167-73. doi: 10.1212/wnl.47.5.1167.
- Bassetti C, Aldrich MS. Sleep apnea in acute cerebrovascular diseases: final report on 128 patients. Sleep. 1999 Mar 15;22(2):217-23. doi: 10.1093/sleep/22.2.217.
- Bassetti CL, Milanova M, Gugger M. Sleep-disordered breathing and acute ischemic stroke: diagnosis, risk factors, treatment, evolution, and long-term clinical outcome. Stroke. 2006 Apr;37(4):967-72. doi: 10.1161/01.STR.0000208215.49243.c3. Epub 2006 Mar 16.
- Pace M, Camilo MR, Seiler A, Duss SB, Mathis J, Manconi M, Bassetti CL. Rapid eye movements sleep as a predictor of functional outcome after stroke: a translational study. Sleep. 2018 Oct 1;41(10). doi: 10.1093/sleep/zsy138.
- Manconi M, Zavalko I, Cereda C, Pisarenco I, Ott S, Fulda S, Bassetti CL. Longitudinal polysomnographic assessment from acute to subacute phase in infratentorial versus supratentorial stroke. Cerebrovasc Dis. 2014;37(2):85-93. doi: 10.1159/000356323. Epub 2014 Jan 16.
- Cereda CW, Petrini L, Azzola A, Ciccone A, Fischer U, Gallino A, Gyorik S, Gugger M, Mattis J, Lavie L, Limoni C, Nobili L, Manconi M, Ott S, Pons M, Bassetti CL. Sleep-disordered breathing in acute ischemic stroke and transient ischemic attack: effects on short- and long-term outcome and efficacy of treatment with continuous positive airways pressure--rationale and design of the SAS CARE study. Int J Stroke. 2012 Oct;7(7):597-603. doi: 10.1111/j.1747-4949.2012.00836.x. Epub 2012 Jul 19.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
- Processi patologici
- Necrosi
- Malattia cardiovascolare
- Malattie vascolari
- Disturbi cerebrovascolari
- Malattie del cervello
- Malattie del sistema nervoso centrale
- Malattie del sistema nervoso
- Malattie delle vie respiratorie
- Apnea
- Disturbi respiratori
- Disturbi del sonno, intrinseci
- Dissonnie
- Disturbi del sonno e della veglia
- Ischemia cerebrale
- Infarto
- Infarto cerebrale
- Ictus
- Sindromi da apnee notturne
- Ictus ischemico
- Ischemia
- Infarto cerebrale
Altri numeri di identificazione dello studio
- EOC.NC.10.01
- 320030-125069/1 (Altro numero di sovvenzione/finanziamento: Swiss National Science Foundation (SNSF))
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Ictus ischemico
-
Yonsei UniversityReclutamentoIschemic Heart Disease | Cardiopatia Non IschemicaCorea del Sud
Prove cliniche su CPAP
-
Centre Hospitalier Intercommunal CreteilPr Xavier DURRMEYERNon ancora reclutamentoDistress respiratorio neonataleFrancia
-
State Key Laboratory of Respiratory DiseaseCompletatoApnea notturna, ostruttiva | Pressione positiva continua delle vie aeree | PolisonnografiaCina
-
University of ZurichSwiss National Science FoundationCompletato
-
Chinese University of Hong KongCompletato
-
Fisher and Paykel HealthcareSuburban Lung AssociatesCompletatoApnea notturna, ostruttivaStati Uniti
-
Federal University of São PauloReclutamentoApnea ostruttiva del sonno (OSA)Brasile
-
Krishna M. SundarCompletato
-
University Hospital, GrenobleCompletatoDeficit di memoriaFrancia
-
University Hospital, LilleCompletatoSindromi da apnee notturne | Epilessie, parzialiFrancia
-
Ohio State UniversityCompletatoArresto cardiaco | Apnea ostruttiva del sonno | Insufficienza cardiaca, congestiziaStati Uniti