Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Usefulness of Light Wand-guided Insertion of Flexible Reinforced Laryngeal Mask Airway

16 ottobre 2018 aggiornato da: Jiyoung Yoo, Ajou University School of Medicine

Usefulness of Light Wand-guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison With Conventional Blind-insertion

Flexible LMA (Laryngeal mask airway) is very useful for variable situation but it is hard to insert in correct position because of it's flexible structure. Especially in classical way of manual LMA insertion, when the index finger could not guide the flexible LMA to the optimal position, we could not guarantee the correct position of the LMA. Therefore several studies have been investigated to improve this.

The light wand is a kind of stylet which have a light on the tip. Recently some studies demonstrated the usefulness of the light wand which could be used for indicating correct position of the LMA. We hypothesised there will be two advantages if the light wand is used as a stylet of the flexible LMA. First the stylet could support the mildness of the flexible LMA, and second the lightness could confirm the correct position of the flexible LMA.

Panoramica dello studio

Stato

Completato

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Effettivo)

54

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 19 anni a 75 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • The patient need general anesthesia using LMA and belonged to the ASA(American society of Anesthesiologist) class I or II

Exclusion Criteria:

  • The patient who has URI(upper respiratory infection) symptom within 14 days or
  • The patient's BMI(body mass index) exceeds 35 kg/m2
  • The patient has severe GERD(gastroesophageal reflux disease) or hiatus hernia
  • The patient who has any contraindication for LMA insertion

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Altro
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Nessun intervento: Control group
The flexible LMA is inserted using "index finger technique"
Comparatore attivo: Light wand group
The flexible LMA is inserted using light wand as a stylet
The light wand is used as a stylet of the flexible LMA. When the investigator inserts the flexible LMA in "light wand group", the correct position of the LMA is confirmed by the light.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Oropharyngeal leak pressure
Lasso di tempo: 5 minutes after LMA is inserted
The oropharyngeal leak pressure is measured by the pressure which the investigator could detect the audible sound by stethoscope on patient's cheek during the exhaust valve is closed and the fresh gas is allowed to flow into the lungs at 3 liters per minute.
5 minutes after LMA is inserted

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
The grade of oropharyngeal view through the fiberoptic assessment
Lasso di tempo: 5 minutes after LMA is inserted
The position of the LMA was assessed by fiberoptic examination through an attachment between the LMA and the anesthetic circuit.
5 minutes after LMA is inserted

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Ji Young Yoo, Clinical Assistant Professor

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 agosto 2017

Completamento primario (Effettivo)

30 settembre 2018

Completamento dello studio (Effettivo)

30 settembre 2018

Date di iscrizione allo studio

Primo inviato

13 luglio 2017

Primo inviato che soddisfa i criteri di controllo qualità

19 luglio 2017

Primo Inserito (Effettivo)

21 luglio 2017

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

17 ottobre 2018

Ultimo aggiornamento inviato che soddisfa i criteri QC

16 ottobre 2018

Ultimo verificato

1 ottobre 2018

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • AJIRB-MED-OBS-17-108

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Maschera laringea delle vie aeree

Prove cliniche su light wand

Sottoscrivi