Ultrasound Guided Cricoid and Paralaryngeal Pressure
Impact of Ultrasound Guidance on the Performance of Accurate Cricoid and Paralaryngeal Pressure
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
All patients consented for the study were having their airway examined via US. Cross sectional sonography of the airway was performed to determine the anatomic relationship of the oesophagus relative to the trachea:
- before induction of anaesthesia
- after GA before external airway pressure manoeuvre
- after GA with external airway pressure manoeuvre.
US guided CP was applied on subjects with central oesophagus; CP and PLP were applied on subject with eccentric oesophagus anatomy.
PLP was performed by lateral compression on the eccentric oesophagus by fingertips under US guidance. To standardised the application of CP and PLP, only 2 well trained investigators were allowed to performed the CP and PLP, US scan on airway and patient recruitment. The conduct of trial involved 2 investigators where first investigator provide US scan, and second investigator provide compression of CP or PLP using fingertips guided by the instruction of first investigator.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Kuala Lumpur, Malaysia, 59100
- University Malaya Medical Centre
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
Elective list Under general anaesthesia Not intubated prior to OT
Exclusion Criteria:
Below 18 years old Pregnant Neck deformities Previous maxillofacial surgery
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Doppio
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Comparatore attivo: Centrally located oesophagus post GA
Oesophagus remained central after general anaesthesia, cricoid pressure applied by fingertips under ultrasound guidance
|
cricoid pressure by fingertips applied under ultrasound guidance
|
|
Sperimentale: Eccentric located oesophagus post GA
Oesophagus eccentric located after general anaesthesia, paralaryngeal pressure and cricoid pressure applied by fingertips under ultrasound guidance
|
cricoid pressure with paralaryngeal pressure by fingertips applied under ultrasound guidance
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
The number of patients with eccentric oesophagus under general anesthesia, successfully occluded by using cricoid and paralaryngeal pressure.
Lasso di tempo: ultrasound assessment of oesophagus done after general anaesthesia, during application of cricoid pressure, and during application of cricoid and paralaryngeal pressure
|
we are studying the effectiveness of cricoid pressure versus cricoid and paralaryngeal pressure(novel technique) in those patients with eccentric oesophagus under general anaesthesia.
We use ultrasound to determined the position of the oesophagus after patient under general anaethesia ( to group them under central oesophagus and eccentric oesophagus) and also to determine the success of oesophagus occlusion.
|
ultrasound assessment of oesophagus done after general anaesthesia, during application of cricoid pressure, and during application of cricoid and paralaryngeal pressure
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
The number of patients with central oesophagus under general anesthesia, successfully occluded by using cricoid pressure.
Lasso di tempo: ultrasound assessment of oesophagus done after general anaesthesia and during application of cricoid pressure
|
The objective is to study the effectiveness of cricoid pressure in those patients with central oesophagus under general anaesthesia.
We use ultrasound to determined the position of the oesophagus after patient under general anaethesia, and also to determine the success of oesophagus occlusion.
|
ultrasound assessment of oesophagus done after general anaesthesia and during application of cricoid pressure
|
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
incidence of variation of oesophagus position before and after general anaesthesia
Lasso di tempo: ultrasound assessment of position of oesophagus before and after general anaesthesia
|
We use ultrasound to determine the position of osephagus (central or eccentric) to determine the incidence of variation of oesophagus position before and after general anaesthesia.
|
ultrasound assessment of position of oesophagus before and after general anaesthesia
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Siu Min Lim, M. Anaes, University of Malaya
Pubblicazioni e link utili
Pubblicazioni generali
- SELLICK BA. Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia. Lancet. 1961 Aug 19;2(7199):404-6. doi: 10.1016/s0140-6736(61)92485-0. No abstract available.
- Andruszkiewicz P, Wojtczak J, Wroblewski L, Kaczor M, Sobczyk D, Kowalik I. Ultrasound evaluation of the impact of cricoid pressure versus novel 'paralaryngeal pressure' on anteroposterior oesophageal diameter. Anaesthesia. 2016 Sep;71(9):1024-9. doi: 10.1111/anae.13518.
- Lee D, Czech AJ, Elriedy M, Nair A, El-Boghdadly K, Ahmad I. A multicentre prospective cohort study of the accuracy of conventional landmark technique for cricoid localisation using ultrasound scanning. Anaesthesia. 2018 Oct;73(10):1229-1234. doi: 10.1111/anae.14399. Epub 2018 Jul 25.
- Rice MJ, Mancuso AA, Gibbs C, Morey TE, Gravenstein N, Deitte LA. Cricoid pressure results in compression of the postcricoid hypopharynx: the esophageal position is irrelevant. Anesth Analg. 2009 Nov;109(5):1546-52. doi: 10.1213/ane.0b013e3181b05404.
- Byas-Smith M, Prinsell JR Jr. Ultrasound-guided esophageal occlusion during rapid sequence induction. Can J Anaesth. 2013 Mar;60(3):327-8. doi: 10.1007/s12630-012-9847-9. Epub 2012 Dec 20. No abstract available.
- Votruba J, Zemanova P, Lambert L, Vesela MM. The Role of Airway and Endobronchial Ultrasound in Perioperative Medicine. Biomed Res Int. 2015;2015:754626. doi: 10.1155/2015/754626. Epub 2015 Dec 14.
- Bhatia N, Bhagat H, Sen I. Cricoid pressure: Where do we stand? J Anaesthesiol Clin Pharmacol. 2014 Jan;30(1):3-6. doi: 10.4103/0970-9185.125683.
- Kei J, Utschig EE, van Tonder RJ. Using Ultrasonography to Assess the Effectiveness of Cricoid Pressure on Esophageal Compression. J Emerg Med. 2017 Aug;53(2):236-240. doi: 10.1016/j.jemermed.2017.04.025. Epub 2017 Jun 8.
- Smith KJ, Dobranowski J, Yip G, Dauphin A, Choi PT. Cricoid pressure displaces the esophagus: an observational study using magnetic resonance imaging. Anesthesiology. 2003 Jul;99(1):60-4. doi: 10.1097/00000542-200307000-00013.
- Smith KJ, Ladak S, Choi PT, Dobranowski J. The cricoid cartilage and the esophagus are not aligned in close to half of adult patients. Can J Anaesth. 2002 May;49(5):503-7. doi: 10.1007/BF03017931.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
- 2018118-6867
- 45835 (National Medical Research Register)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .