Study on the Measurement Method of the Left Diaphragm (LD)
To Study the Consistency of Multiple Measurement Methods of Left Diaphragm Mobility in Critically Ill Patients
調査の概要
状態
状態
条件
条件
研究の種類
研究の種類
入学 (推定)
入学
参加基準
適格基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
①Adult patients (≥18 years old) of both sexes;
In invasive group, intubation or tracheotomy was changed to 5L/min T-tube or tracheotomy mask oxygen inhalation;
Patients in non-invasive group were treated with mask oxygen 5L/min;
- agree to participate in the trial and sign the informed consent;
Exclusion Criteria:
①The diaphragm ultrasound operation site was too large to obtain images.
Diaphragmatic ultrasound images could not be obtained in any section;
The ultrasound image quality of any section was poor;
- the presence of phrenic nerve injury/paralysis ⑤ pregnant women; ⑥ Neuromuscular diseases such as ALS and myasthenia gravis affect the evaluation of spontaneous breathing ⑦ Patients deemed by the investigator to be ineligible.
研究計画
研究はどのように設計されていますか?
デザインの詳細
グループ/コホートの数
コホートと介入
グループ/コホートグループ/コホート |
|---|
|
Invasive respiratory support group
The subjects of ultrasound measurement were patients with invasive mechanical ventilation
|
|
Noninvasive respiratory support group
The subjects of ultrasound measurement were patients with non-invasive respiratory support
|
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Consistency of diaphragmatic mobility measurements between the standard and modified positions on the left side.
時間枠:Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
The main purpose is to verify the consistency of the two methods, Measurements were performed after switching patients in the invasive group (intubated patients to T-piece oxygen at 5 L/min and tracheostomized patients to face mask oxygen at 5 L/min following weaning), and patients in the non-invasive group (those receiving non-invasive ventilation or high-flow oxygen therapy) to conventional face mask oxygen at 5 L/min.
|
Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Consistency of diaphragmatic excursion measurements between the standard position and the other four positions on the left side.
時間枠:Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
Consistency of measurement methods,Measurements were performed after switching patients in the invasive group (intubated patients to T-piece oxygen at 5 L/min and tracheostomized patients to face mask oxygen at 5 L/min following weaning), and patients in the non-invasive group (those receiving non-invasive ventilation or high-flow oxygen therapy) to conventional face mask oxygen at 5 L/min.
|
Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
|
Consistency of diaphragmatic excursion measurements between the standard position and the other five positions on the right side.
時間枠:Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
Consistency of measurement methods,Measurements were performed after switching patients in the invasive group (intubated patients to T-piece oxygen at 5 L/min and tracheostomized patients to face mask oxygen at 5 L/min following weaning), and patients in the non-invasive group (those receiving non-invasive ventilation or high-flow oxygen therapy) to conventional face mask oxygen at 5 L/min.
|
Measurements were performed 5 minutes after all patients were switched to conventional oxygen therapy at 5 L/min for the first time, once breathing had stabilized.
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
その他の研究ID番号
- B2026-162
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。