Accurate measures of kidney function is important for precision dosing of many medications. The current methods of determining kidney function largely hinge on the use of equations that use common laboratory values such as serum creatinine & static variables like age & weight. These are helpful for trending over time, but often are inaccurate during times of medical illness. Other more accurate methods of measuring kidney function include urine collection, although this is not commonly used because of various reasons that make the collection inconvenient or unreliable. The new transdermal glomerular filtration (tGFR) device permits accurate, real-time evaluation of kidney function. This novel method has not been rigorously compared with urine collection & other methods of determining kidney function in hospitalized patients. The goal of the study is to compare tGFR with other accepted methods of determining kidney function.

調査の概要

状態

まだ募集していません

条件

介入・治療

詳細な説明

The majority of acutely ill patients exhibit changes in renal function due to inflammation, increased solute generation, and iatrogenic factors such as fluid resuscitation and vasopressors. The pharmacokinetics of renally eliminated medications (eg. levetiracetam, cefepime, vancomycin) are frequently affected by inflammatory processes despite normal estimations in creatinine clearance resulting in suboptimal serum drug concentrations and therapeutic failure. Despite the prevalence of fluctuations in renal function in acute illness, real-time assessment is limited to monitoring of serum biomarkers such as creatinine and cystatin C, as well as urine output, which typically lag behind important changes in function. Furthermore, use of creatinine clearance equations based on anthropomorphic data correlates poorly with actual renal function, potentially misleading clinicians as to the progression of disease and the need for dose adjustment of important medications in this vulnerable population.

Limitations of current approaches for evaluating renal function in the acutely ill Estimation of GFR or creatinine clearance can be accomplished by numerous equations, the majority of which have been validated in non-critically ill adults, usually with a relatively high percent of patients with chronic kidney disease. These equations are often not accurate in patients with acutely worsening renal function. Likewise, while these equations are helpful for categorizing renal function and assessing appropriate medication dosing in otherwise healthy, ambulatory patients. Under-prediction of creatinine clearance values leads clinicians to consistently under-dose critical medications such as beta-lactam antibiotics, vancomycin, or antiseizure medications such as levetiracetam.

Proactive measurement of creatinine clearance can provide a more accurate depiction of GFR but is fraught with complications. Iohexol serum concentrations correlate well with GFR, but requires intravenous administration of iohexol, which has a small risk of infusion reaction and hypersensitivity, and serial blood samples. Measured urine creatinine clearance is also feasible but inconvenient in most hospitalized patients. mClCr requires bladder catheterization for accurate urine volume, consistent storage on ice for the duration of collection (between 8 and 24 hours), and prompt delivery of the large volume container to the local laboratory for creatinine analysis. Each of these criteria introduce variability into the measurement and are often unnoticed or undocumented, introducing inaccuracy into the mClCr values. The lack of a real-time, accurate assessment of creatinine clearance in the acutely ill population is a gap in practice and represents a resolvable problem in the process of individualized and precision dosing of medications in this vulnerable and high-risk population.

This study represents an important innovation in advancing the understanding of fluctuations in renal function during acute illness. The current study will validate the safety of transdermal GFR monitoring to provide real-time measurement of renal function in patients with stable renal function. Further, the reliability of transdermal GFR monitoring will be compared to current standards of renal function assessment. The results of this study will advance the field by validating the use of a real-time physiologic assessment of GFR rather than using labor intensive, invasive tests that may lag behind current renal function. Numerous important gaps remain with this new technology, including use primarily in the ambulatory, stable renal function populations. Thus, this study is potentially the first step in evaluating renal function across the acute care continuum.

研究の種類

介入

入学 (推定)

200

段階

  • フェーズ 4

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Aaron Cook, PharmD
  • 電話番号:18592578444
  • メール:amcook0@uky.edu

研究場所

    • Kentucky
      • Lexington、Kentucky、アメリカ、40536
        • UKHealthCare/University of Kentucky

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • 18-65 years old
  • critically ill or acutely ill hospitalized patients admitted to the intensive care unit
  • Stable/normal renal function

Exclusion Criteria:

  • Prisoners
  • Pregnant women
  • Laboratory evidence of unstable kidney function (KDIGO AKI stage 1-3--This includes subjects with Scr > 1.5x baseline)

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:MediBeacon Transdermal Glomerular Filtration Rate (GFR) Monitoring
IV push of relmapirazin (Lumitrace) prior to use of the tGFR device
Small IV push bolus of iohexol as a probe for renal function will be administered prior to use of the tGFR device.
The tGFR monitor will be applied to the patient after relmapirazin bolus for measurement of GFR.
8-hour urine creatinine clearance collection will be performed during the study period to compare to tGFR & other renal function measures.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Transdermal Glomerular Filtration Rate (tGFR) Monitoring Accuracy
時間枠:8 Hours
Accuracy of transdermal glomerular filtration rate (GFR) monitoring compared with measured urine creatinine clearance.
8 Hours

二次結果の測定

結果測定
メジャーの説明
時間枠
Relmapirazin Elimination Half-Life
時間枠:12 hours
Elimination half-life of Relmapirazin calculated from serial serum concentration measurements obtained over 12 hours following intravenous administration.
12 hours
Iohexol Elimination Half-Life
時間枠:12 hours
Elimination half-life of Iohexol calculated from serial serum concentration measurements obtained over 12 hours following intravenous administration.
12 hours

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Aaron M Cook, PharmD、University of Kentucky College of Pharmacy, Department of Pharmacy Practice & Science
  • スタディディレクター:Juan-Carlos Aycinena, MD、University of Kentucky College of Medicine, Department of Nephrology

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年9月1日

一次修了 (推定)

2028年5月31日

研究の完了 (推定)

2028年6月30日

試験登録日

最初に提出

2026年5月8日

QC基準を満たした最初の提出物

2026年6月8日

最初の投稿 (実際)

2026年6月11日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月3日

QC基準を満たした最後の更新が送信されました

2026年8月31日

最終確認日

2026年8月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 105008

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

はい

米国FDA規制機器製品の研究

はい

米国で製造され、米国から輸出された製品。

はい

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。