Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot
Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot: A Prospective, Multicenter Study
This prospective, multicenter, intraindividual paired study aims to evaluate the autonomous scanning performance of a dual-arm robotic breast ultrasound system and the diagnostic performance of the images it acquires, in comparison with conventional handheld ultrasound. The study primarily focuses on the agreement between diagnostic assessments based on images obtained using the two examination methods, while also evaluating image quality, lesion detection, and measurement performance. The robotic ultrasound findings will be collected for research purposes only and will not be used to guide clinical management; all clinical decisions will be based on routine clinical assessment.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
This is a prospective, multicenter, non-randomized, intraindividual paired clinical study. All eligible participants will undergo both autonomous breast ultrasound scanning using a dual-arm robotic ultrasound system and conventional handheld ultrasound examinations, with complete ultrasound images and videos retained for both examinations. Two senior ultrasound experts will independently review images from both modalities in a blinded manner, assessing lesion detection, localization, long and short diameters, sonographic features, and Breast Imaging Reporting and Data System (BI-RADS) categories. Disagreements will be resolved by a third expert.
The primary outcome is the agreement between expert BI-RADS assessments based on robotic ultrasound images and those based on conventional handheld ultrasound images. Secondary outcomes include imaging completeness and quality, lesion detection and localization, agreement in lesion size measurements, and patient-reported examination experiences. Additionally, the study will explore the patient-level diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of both examination methods for breast cancer detection, as well as the impact of the robotic ultrasound AI-assisted diagnostic system on physicians' diagnostic performance.
研究の種類
研究の種類
入学 (推定)
入学
連絡先と場所
研究連絡先
研究連絡先
- 名前:Xiaoxv Yin
- 電話番号:+8613871187781
- メール:yxx@hust.edu.cn
研究場所
-
-
Hubei
-
Shiyan、Hubei、中国、442000
- 募集
- Taihe Hospital of Shiyan City
-
コンタクト:
- Xiaoxv Yin, Doctor
- 電話番号:86+13871187781
- メール:yxx@hust.edu.cn
-
Wuhan、Hubei、中国、430016
- まだ募集していません
- Wuhan Children's Hospital
-
コンタクト:
- Xiaoxv Yin
- 電話番号:13871187781
- メール:yxx@hust.edu.cn
-
Wuhan、Hubei、中国、430030
- 募集
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology (Optical Valley Branch)
-
コンタクト:
- Xiaoxv Yin
- 電話番号:+86 13871187781
- メール:yxx@hust.edu.cn
-
Xiantao、Hubei、中国、433000
- 募集
- Xiantao First People's Hospital
-
コンタクト:
- Xiaoxv Yin
- 電話番号:+86 13871187781
- メール:yxx@hust.edu.cn
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Participants will be recruited from the breast ultrasound outpatient clinics of three participating hospitals in Hubei Province, China. The study population will consist of adults aged 18-80 years with no history of breast cancer who voluntarily participate in breast ultrasound screening. All eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound.
説明
Inclusion Criteria:
- Aged 18-80 years.
- No history of breast cancer.
- Willing to voluntarily participate in breast screening.
Exclusion Criteria:
- History of breast resection surgery.
- Pregnant or breastfeeding women.
- Presence of prosthetic implants.
- Women with an allergy to ultrasound coupling gel.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:PROSPECTIVE
グループ/コホートの数
コホートと介入
グループ/コホートグループ/コホート |
介入・治療介入・治療 |
|---|---|
|
Breast Ultrasound Screening Cohort
Eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound. |
Participants will undergo autonomous dual-arm robotic breast ultrasound after conventional handheld ultrasound. The system will autonomously perform breast scanning and acquire ultrasound images for subsequent evaluation of imaging and diagnostic performance. The robotic ultrasound results will not be used to guide clinical management. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Agreement Between Expert BI-RADS Classifications Based on Robotic and Handheld Breast Ultrasound Images
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Proportion of Examinations With Complete Breast Coverage Assessed by Expert Review of Ultrasound Recordings
時間枠:6 weeks after completion of image collection for all participants
|
Breast scanning completeness will be assessed through expert review of the complete ultrasound recordings obtained using robotic and handheld ultrasound. Each examination will be classified as complete or incomplete (Yes/No) according to whether the predefined breast scanning regions are adequately covered. The outcome will be reported as the percentage of complete examinations for each modality. |
6 weeks after completion of image collection for all participants
|
|
Overall Breast Ultrasound Image Quality Assessed Using a 5-Point Expert Rating Scale
時間枠:6 weeks after completion of image collection for all participants
|
Overall image quality will be evaluated by experienced breast ultrasound experts using a 5-point ordinal rating scale (1 = poorest quality; 5 = best quality) based on the complete ultrasound recordings acquired using each modality. |
6 weeks after completion of image collection for all participants
|
|
Lesion-Level Detection Sensitivity
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Mean Number of False-Positive Lesion Detections per Breast Ultrasound Examination
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Lesion Detection Precision
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Proportion of Breast Lesions With Accurate Localization Based on Expert Reference Assessment
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Agreement in Lesion Diameter Measurements
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Agreement Between Robotic and Handheld Ultrasound in Sonographic Features (Shape, Orientation, Margin, Echogenicity, and Posterior Acoustic Features) of Breast Lesions
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Patient-Reported Overall Satisfaction Score Using a 5-Point Questionnaire
時間枠:6 weeks after completion of image collection for all participants
|
Responses will be coded on a 5-point ordinal scale: 1 = very dissatisfied, 2 = dissatisfied, 3 = neutral, 4 = satisfied, and 5 = very satisfied. Higher scores indicate greater satisfaction. |
6 weeks after completion of image collection for all participants
|
|
Patient-Reported Pain Score Assessed Using a Study-Specific 5-Point Scale
時間枠:6 weeks after completion of image collection for all participants
|
Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety. |
6 weeks after completion of image collection for all participants
|
|
Patient-Reported Anxiety Score Assessed Using a Study-Specific 5-Point Scale
時間枠:6 weeks after completion of image collection for all participants
|
Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety. |
6 weeks after completion of image collection for all participants
|
|
Patient-Reported Probe Pressure Score Assessed Using a Study-Specific 5-Point Scale
時間枠:6 weeks after completion of image collection for all participants
|
Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety. |
6 weeks after completion of image collection for all participants
|
|
Patient-Level Sensitivity for Breast Cancer Detection
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Patient-Level Specificity for Breast Cancer Detection
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Area Under the Receiver Operating Characteristic Curve (AUC) for Patient-Level Breast Cancer Detection
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Change in Patient-Level Sensitivity With Versus Without AI Assistance (Percentage Points)
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Change in Patient-Level Specificity With Versus Without AI Assistance (Percentage Points)
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
|
|
Change in Area Under the Receiver Operating Characteristic Curve (AUC) With Versus Without AI Assistance
時間枠:6 weeks after completion of image collection for all participants
|
6 weeks after completion of image collection for all participants
|
協力者と研究者
協力者
協力者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
その他の研究ID番号
- HuazhongU2026
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。