Accuracy of Full-Arch Implant Placement Using Two Guided Surgical Workflows in Terminal Mandibular Dentition
Accuracy of Full-Arch Implant Placement in the Terminal-Dentition Mandible Using Stackable Versus Sequential Tooth-Supported Surgical Guides: A Retrospective Comparative Clinical Study
This retrospective clinical study aims to evaluate the accuracy of full-arch dental implant placement in patients with terminal mandibular dentition using two different computer-guided surgical approaches.
Patients with terminal mandibular dentition often require extraction of their remaining teeth and placement of multiple dental implants to support a fixed full-arch prosthesis. Accurate implant placement is important for achieving a favorable prosthetic outcome and avoiding anatomical complications.
The study will compare two surgical workflows. The first uses a stackable surgical guide system in patients who require reduction of the jawbone to create adequate space for the final prosthesis. The second uses sequential tooth-supported surgical guides in patients who do not require bone reduction. These guides are used in stages during tooth extraction and implant placement to help transfer the digitally planned implant positions to the patient's jaw.
The researchers will review the clinical records, original digital treatment plans, and radiographic images of previously treated patients at the Faculty of Dentistry, Menoufia University. Patients treated between 2024 and 2026 who meet the study eligibility criteria will be considered.
The accuracy of implant placement will be assessed by comparing the planned implant positions with the actual positions identified from postoperative three-dimensional imaging. The researchers will measure differences at the implant platform and tip, as well as differences in implant angulation.
The study aims to determine whether the two guided surgical workflows differ in implant placement accuracy and to provide clinical information that may help clinicians select an appropriate guided surgical approach for patients requiring mandibular full-arch implant rehabilitation.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
This retrospective comparative clinical study will evaluate the accuracy of computer-guided full-arch implant placement in patients with terminal mandibular dentition treated using two different indication-based surgical workflows.
The study will be conducted at the Department of Prosthetic Dental Science, Faculty of Dentistry, Menoufia University, through a retrospective review of clinical records, preoperative digital treatment plans, surgical documentation, and postoperative radiographic datasets of patients treated between 2024 and 2026.
**Study population and group classification**
Adult patients aged 45-65 years who underwent mandibular full-arch implant rehabilitation for terminal dentition will be screened for eligibility. Eligible patients must have available preoperative cone-beam computed tomography (CBCT) images, intraoral scans, original digital implant planning files, postoperative CBCT datasets, and adequate surgical documentation.
Patients will be categorized into two groups according to the surgical workflow originally selected during their clinical treatment:
**Group I: Stackable surgical guide workflow**
This group will include patients who required alveolar ridge reduction to establish adequate restorative space and appropriate residual ridge morphology. An anatomical-form basal guide initially supported by the remaining natural teeth will be used. Following tooth extraction, the guide will transition to a bone-supported configuration through its fixation mechanism. Subsequent stackable components will facilitate alveolar ridge reduction and guided implant placement.
**Group II: Sequential tooth-supported surgical guide workflow**
This group will include patients who did not require alveolar ridge reduction because adequate restorative space and residual ridge morphology were available. Separate tooth-supported surgical guide components will be used sequentially during tooth extraction and implant placement. Depending on the remaining dental support, the guide configuration may be modified to obtain combined tooth- and mucosa-supported stabilization during the subsequent surgical stages.
The original indication for each surgical approach will be verified using the preoperative digital treatment plan and surgical records. Group allocation will not be randomized.
**Digital planning and surgical procedures**
Preoperative CBCT datasets and intraoral scanning files will be integrated using dedicated implant planning software. Virtual implant positioning will follow prosthetically driven principles, considering the available bone dimensions, anatomical structures, planned definitive prosthesis, implant distribution, and restorative requirements.
Both groups will be treated using the same implant manufacturer and implant system. Implant placement may be performed immediately following tooth extraction or in previously healed extraction sites, according to the original surgical plan. The timing of implant placement will be recorded for each implant.
An intended immediate-loading protocol will be used in both groups. Implant primary stability, insertion torque, and/or implant stability quotient values will be extracted from the original clinical records. Immediate loading will be defined as connecting a provisional prosthesis in functional occlusion within one week following implant placement.
**Assessment of implant placement accuracy**
The primary objective will be to compare the accuracy of the two surgical workflows by assessing the discrepancy between virtually planned and actual postoperative implant positions.
Preoperative and postoperative CBCT datasets will be registered using stable mandibular anatomical structures that were not altered during surgery. In patients who underwent alveolar ridge reduction, unaffected anatomical regions will be used for image registration rather than the surgically modified alveolar crest.
The planned and actual implant positions will then be superimposed in a common coordinate system, and the following parameters will be evaluated:
- Three-dimensional coronal deviation (mm): The distance between the centers of the planned and actual implant platforms.
- Three-dimensional apical deviation (mm): The distance between the planned and actual implant apex positions.
- Angular deviation (degrees): The angular difference between the longitudinal axes of the planned and actual implants.
Three-dimensional coronal deviation will represent the primary accuracy outcome, while apical and angular deviations will represent secondary outcomes.
**Measurement reliability**
Measurements will be performed by an independent calibrated examiner who will be blinded to the treatment group whenever feasible. A randomly selected subset of implants will undergo repeated measurements after an interval of at least two weeks. Intra-examiner reliability will be assessed using the intraclass correlation coefficient (ICC).
**Additional variables and statistical analysis**
Demographic, anatomical, implant-related, and surgical variables will be extracted from the original clinical records. These will include age, sex, smoking status, systemic health conditions, mandibular bone dimensions, implant position, implant dimensions, implant placement timing, primary stability measurements, guide support configuration, fixation mechanisms, surgical duration, and documented complications.
Continuous variables will be summarized using means and standard deviations or medians and interquartile ranges, as appropriate. Categorical variables will be presented as frequencies and percentages.
Linear mixed-effects models will be used to compare implant placement accuracy between the two surgical workflows while accounting for the hierarchical structure of the data, with multiple implants nested within individual patients. Patient identification will be incorporated as a random effect, and surgical workflow will be included as the main explanatory variable. Potential patient- and implant-level covariates will be considered in adjusted analyses when clinically and statistically appropriate.
Effect estimates with 95% confidence intervals and corresponding P values will be reported. Statistical significance will be established at P < .05.
The findings are expected to provide clinical evidence regarding the accuracy of two indication-based digital guided surgical workflows for mandibular full-arch implant rehabilitation.
研究の種類
研究の種類
入学 (推定)
入学
連絡先と場所
研究連絡先
研究連絡先
- 名前:Mohammed A. El-Sawy, PhD
- 電話番号:00201061314522
- メール:Dr_Sawy@windowslive.com
研究連絡先のバックアップ
- 名前:Mohammed A. Lecturer, PhD
- 電話番号:00201061314522
- メール:mohamed.elsawy@dent.menofia.edu.eg
研究場所
-
-
Menoufia
-
Shibīn al Kawm、Menoufia、エジプト、2266166
- 募集
- Faculty of Dentistry, Menoufia University
-
コンタクト:
- Mohammed A. El-Sawy, PhD
- 電話番号:00201061314522
- メール:mohamed.elsawy@dent.menofia.edu.eg
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Patients aged 45-65 years with terminal mandibular dentition who underwent full-arch implant-supported rehabilitation using either a stackable surgical guide system or sequential tooth-supported surgical guides at the Faculty of Dentistry, Menoufia University, between 2024 and 2026. Eligible patients must have adequate preoperative digital planning records, postoperative CBCT datasets, and complete clinical and surgical documentation to permit retrospective assessment of implant placement accuracy.
説明
Inclusion Criteria
- Adult patients aged 45-65 years.
- Presence of terminal mandibular dentition requiring extraction of the remaining natural teeth and full-arch implant-supported rehabilitation.
- Treatment performed using either a stackable surgical guide system or sequential tooth-supported surgical guides.
- Availability of preoperative CBCT imaging and digital intraoral scans suitable for virtual implant planning.
- Availability of the original virtual implant planning files documenting the planned implant positions, dimensions, and angulations.
- Availability of postoperative CBCT datasets of sufficient quality to identify the actual implant positions and implant apices.
- Availability of adequate clinical and surgical records documenting the guide configuration, bone reduction requirements, and implant placement sequence.
Exclusion Criteria
- Patients with incomplete or unavailable preoperative digital planning records.
- Cases with missing or inadequate postoperative CBCT datasets that prevent reliable implant position assessment.
- Patients who underwent extensive simultaneous bone augmentation procedures that substantially altered the planned surgical workflow.
- Cases involving freehand implant placement rather than the intended guided surgical approach.
- Patients with incomplete surgical records regarding the type of surgical guide or the indication for alveolar ridge reduction.
- Cases in which severe metallic artifacts or image distortion prevent reliable identification of the implant platform or apex.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:RETROSPECTIVE
グループ/コホートの数
コホートと介入
グループ/コホートグループ/コホート |
介入・治療介入・治療 |
|---|---|
|
Stackable Surgical Guide Group
Patients with terminal mandibular dentition who underwent full-arch implant rehabilitation using a stackable surgical guide system because preoperative prosthetic and surgical planning indicated the need for alveolar ridge reduction. The guide system was initially supported by the remaining natural teeth and subsequently transitioned to a bone-supported configuration following tooth extraction to facilitate alveolar ridge reduction and guided implant placement. |
A computer-guided surgical workflow previously used in patients requiring alveolar ridge reduction before full-arch implant rehabilitation. The procedure involved initial tooth-supported positioning of an anatomical-form basal guide, transition to bone-supported positioning following tooth extraction, guided alveolar ridge reduction, and subsequent guided implant placement using stackable guide components. |
|
Sequential Tooth-Supported Surgical Guide Group
Patients with terminal mandibular dentition who underwent full-arch implant rehabilitation using sequential tooth-supported surgical guides because adequate restorative space and residual ridge morphology were available without alveolar ridge reduction. Separate guide components were used sequentially during tooth extraction and guided implant placement, with modifications to guide support according to the remaining natural teeth. |
A computer-guided surgical workflow previously used in patients who did not require alveolar ridge reduction. Separate tooth-supported surgical guide components were used sequentially during tooth extraction and implant placement, with guide support modified according to the remaining natural teeth and, when necessary, combined tooth- and mucosa-supported stabilization. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Three-Dimensional Coronal Deviation (mm)
時間枠:At the time of postoperative CBCT assessment following implant placement (retrospective evaluation of available radiographic records).
|
The three-dimensional Euclidean distance (mm) between the center of the virtually planned implant platform and the center of the actual implant platform identified on postoperative CBCT images. This outcome will be used to compare implant placement accuracy between the stackable surgical guide group and the sequential tooth-supported surgical guide group. Measurements will be recorded for each implant. |
At the time of postoperative CBCT assessment following implant placement (retrospective evaluation of available radiographic records).
|
|
Three-Dimensional Apical Deviation (mm)
時間枠:At the time of postoperative CBCT assessment following implant placement (retrospective evaluation of available radiographic records).
|
The three-dimensional Euclidean distance (mm) between the planned implant apex and the actual implant apex identified on postoperative CBCT images. This outcome will be used to compare apical implant positioning accuracy between the stackable surgical guide group and the sequential tooth-supported surgical guide group. Measurements will be recorded for each implant. |
At the time of postoperative CBCT assessment following implant placement (retrospective evaluation of available radiographic records).
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
その他の研究ID番号
- ADMNF220926
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Up on reasonable request from the corresponding author.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。