Peds Proton Therapy

2026年11月13日 更新者:University of Wisconsin, Madison

Operational and Clinical Evaluation of the Treatment Planning Software and Oncology Information System for Pediatric Proton Therapy

This study is being done to evaluate the clinical utilization and safety of RayStation 2025 and RayCare 2025 treatment planning software upgrades when used to support standard-of-care proton therapy delivery in patients deemed clinically appropriate for such therapy by their treating radiation oncologist.

調査の概要

状態

募集

条件

介入・治療

詳細な説明

In this study, the radiation treatment itself, including target definitions, prescription dose, treatment delivery, verification imaging, and adaptive treatment planning, is standard of care.

Current standard radiation therapy planning is based on a treatment plan generated from a planning computed tomography (CT) scan obtained before treatment begins. This plan is generally used for the entire course of therapy, with verification imaging performed during treatment primarily used to verify patient positioning rather than to recalculate delivered dose. On occasion, it is standard practice for a physician to determine, based on his or her interpretation of verification imaging, that an adaptive replanning of the treatment is needed to account for anatomic changes that the physician observes on verification imaging which mandate a change to the plan. Comprehensive software-based evaluation of the cumulative dose delivered over multiple fractions is not routinely performed in most clinical settings. Performing such evaluations typically requires manual steps including image registration, dose recalculation on additional imaging datasets, deformable dose mapping, and manual accumulation of dose across fractions. With currently FDA-approved tools for proton therapy treatment plan evaluation, these processes are time-consuming and require significant physics and physician resources. As a result, detailed adaptive dose evaluation is usually performed only in selected cases or as a one-time assessment during a treatment course, rather than as a routine component of daily clinical care.

The investigational component involves the prospective evaluation of the RayAdaptive and RayTracker software tools to assess their performance, reliability, usability, and clinical feasibility. These software features are not currently available for routine clinical use, being not yet FDA-cleared, in the configuration evaluated in this protocol and are being assessed in a defined prospective clinical research setting.

This is a nonrandomized, single arm, open-label, prospective interventional trial to determine the rate of adaptive replanning for proton therapy when RayTracker and RayAdaptive are used as decision-support tools in the analysis of every verification image obtained during each participant's proton therapy treatment course. This study will evaluate, under a defined prospective clinical research framework, the performance, reliability, usability, and clinical feasibility of implementing RayTracker and RayAdaptive - software components that have not yet been 510(k) cleared by the U.S. Food and Drug Administration (FDA).

Primary Objective

• To determine the frequency of adaptive replanning during proton therapy when RayTracker and RayAdaptive are incorporated into routine verification image review as clinical decision-support tools.

Secondary Objectives

  • To evaluate the treating physician-reported rate at which RayTracker and RayAdaptive influenced the decision to pursue adaptive replanning during proton therapy.
  • To explore concordance between RayAdaptive-predicted inadequate target coverage on verification imaging and findings on repeat CT simulation when performed.
  • To explore concordance between RayAdaptive-predicted organ-at-risk dose constraint violations and findings on repeat CT simulation when performed.
  • To report the incidence of adverse events (AEs) and device deficiencies related to the investigational RayTracker/RayAdaptive software.

研究の種類

介入

入学 (推定)

80

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

    • Wisconsin
      • Madison、Wisconsin、アメリカ、53792
        • 募集
        • University of Wisconsin

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

17年歳未満 (子)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Age less than or equal to 17 years at the time of consent/assent.
  • Patient has a clinical indication for radiation therapy, and the treating radiation oncologist has independently determined that proton therapy is clinically appropriate and has recommended proton therapy as part of the patient's routine clinical care, independent of participation in this research study. Proton therapy may be delivered with or without anesthesia when clinically indicated.
  • Written informed consent will be obtained from adult subjects or the parent/legal guardian of pediatric subjects. Assent will be obtained from pediatric participants when appropriate according to institutional policy.

Exclusion Criteria:

  • Patient has contraindications to proton therapy (per standard clinical guidelines).
  • Patient is unable to comply with routine treatment workflow or follow-up.
  • Patients who will be treated with a radiation plan of 5 fractions or fewer.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Standard of Care Proton Therapy

Part of a not yet FDA-cleared software, the RaySearch treatment planning system and RayCare oncology information system. RayTracker enables longitudinal evaluation of treatment by recalculating dose on daily images and accumulating dose across fractions using deformable image registration, thereby providing an estimate of the cumulative delivered dose to targets and organs at risk. RayAdaptive uses daily treatment imaging (such as cone-beam CT (CBCT)) together with the planning CT to generate an updated representation of patient anatomy and recalculation of dose on the current patient anatomy, allowing clinicians to evaluate whether anatomical changes could meaningfully alter the planned dose distribution. These features are designed to be used in tandem. Their combined capabilities are intended to support clinical decision-making related to treatment monitoring and potential adaptation.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Proportion of verification image assessments for each subject resulting in a clinical adaptive replanning decision
時間枠:up to 6 months

Defined as ordering repeat CT simulation and/or treatment plan reoptimization.

up to 6 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Treating physician-reported influence of RayTracker/RayAdaptive on adaptive replanning decisions
時間枠:up to 6 months

Can I define this outcome to be: Did the RayTracker / RayAdaptive intervention influence your clinical decision? [Yes / No] This will be reported by physician count.

up to 6 months
Concordance between RayAdaptive predictions of inadequate target coverage and findings on repeat CT simulation
時間枠:up to 6 months
up to 6 months
Concordance between RayAdaptive predictions of organ-at-risk dose constraint violations and findings on repeat CT simulation
時間枠:up to 6 months
up to 6 months
Incidence of AEs and device deficiencies
時間枠:up to 6 months

Incidence of AEs and device deficiencies at least possibly related to use of the investigational RayTracker/RayAdaptive software or its incorporation into the clinical workflow as assessed throughout the course of proton therapy and for 90 days following completion of proton treatment. Device deficiencies may include software malfunction, calculation error, deformable registration failure, software defect, or software limitations affecting treatment plan evaluation, image review, or data analysis.

up to 6 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Brett Morris, MD, PhD、UW School of Medicine and Public Health

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年10月13日

一次修了 (推定)

2029年1月1日

研究の完了 (推定)

2029年1月1日

試験登録日

最初に提出

2026年11月13日

QC基準を満たした最初の提出物

2026年11月13日

最初の投稿 (実際)

2026年11月19日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月19日

QC基準を満たした最後の更新が送信されました

2026年11月13日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 2026-1312
  • Protocol Version 7/26/26 (その他の識別子:UW Madison)
  • SMPH | Radiation Medicine (その他の識別子:UW Madison)
  • UW26111 (その他の識別子:OnCore ID)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD 共有サポート情報タイプ

  • STUDY_PROTOCOL
  • SAP

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

はい

米国で製造され、米国から輸出された製品。

はい

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。