網膜疾患における桿体と錐体介在機能
Background:
Retinal diseases cause the loss of rod and cone photoreceptors. Symptoms include vision loss and night blindness. Researchers want to learn about rod and cone function in healthy people and people with retinal disease. They want to know if how well a person sees in the dark can test the severity of retinal disease.
Objectives:
To find out if how well a person sees in the dark can test the severity of retinal disease. To find out if this can help detect retinal disease and track its changes.
Eligibility:
People ages 5 and older with:
Retinal disease OR
20/20 vision or better with or without correction in at least one eye
Design:
Participants will be screened with medical and eye history and eye exam. Those with retinal disease will also have:
Eye imaging: Drops dilate the eye and pictures are taken of it.
Visual field testing: Participants look into a bowl and press a button when they see light.
Electroretinogram (ERG): An electrode is taped to the forehead. Participants sit in the
dark with their eyes patched for 30 minutes. Then they get numbing drops and contact
lenses. Participants watch lights while retina signals are recorded.
Visit 1 will be 3-8 hours. Participants will have up to 6 more visits over 6-12 months. Visits include:
Eye exam and imaging
Time course of dark adaptation: Participants view a background light for 5 minutes then
push a button when they see colored light.
Dark adapted sensitivity: Participants sit in the dark for 45 minutes. They push a button when
they see colored light.
For participants with retinal disease, ERG and visual field testing
...
調査の概要
詳細な説明
Objective: The objective of this protocol is to investigate local changes in rod and cone photoreceptor function across the retina in healthy volunteers and participants with retinal disease.
Study Population: Up to 250 healthy volunteers and 250 participants, age five or older, with retinal disease.
Design: This single-center, observational, case-control study will be comprised of three related Aims that assess rod and cone function with commercial perimeters and/or a commercial Cambridge Research Systems computer monitor (Display++) specialized for displaying stimuli at low light intensities. For Aim 1 the normal retinal sensitivity ranges will be established for both fundus-guided and non-guided perimeters. For Aim 2, the normal range for describing the kinetics of dark adaptation following bleaching of retinal rhodopsin will be established for the fundus-guided and non-guided perimeters. For Aim 3, local changes in rod and cone photoreceptor function across the retina in participants with retinal disease will be examined from measurement of the kinetics of dark adaptation, scotopic and photopic retinal sensitivity, and/or Radial Frequency (RF) hyperacuity on the Display++ monitor. Testing may also include patient reported outcome (PRO) questionnaires to assess vision problems under low luminance conditions. For Aim 4, a subset of retinal disease participants (approximately 40) will complete two electroretinogram (ERG) sessions to develop a scaling factor to allow comparison with historical clinical data. The scaling factor will be used in the NEI ophthalmology clinic to account for changes in ERG parameters in patients tested using the current system compared to older clinical results.
Outcome Measures: The primary outcome for this study is to establish normal ranges for A) the kinetics of dark adaptation (time), B) retinal sensitivity (dB) for the fundus-guided and non-guided perimeters, and C) RF hyperacuity on the Display++ monitor. The secondary outcomes will be to examine changes in the kinetics of dark adaptation, scotopic and photopic retinal sensitivity, and/or RF hyperacuity in participants with retinal disease and potentially correlate these clinical measures with patients self-reported evaluation of their vision under low luminance conditions. An exploratory outcome will be to define a scaling factor for ERGs recorded with the RM electrode on the MonCV electrophysiology systems (MonCvONE and MonPackONE, Metrovision France) with the ERG data previously recorded with the Burian-Allen (BA) electrode on the commercial UTAS(TM) electrophysiology system.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Daniel W Claus, R.N.
- 電話番号:(301) 451-1621
- メール:daniel.claus@nih.gov
研究連絡先のバックアップ
- 名前:Brett G Jeffrey, Ph.D.
- 電話番号:(301) 402-2391
- メール:jeffreybg@mail.nih.gov
研究場所
-
-
Maryland
-
Bethesda、Maryland、アメリカ、20892
- 募集
- National Institutes of Health Clinical Center
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Up to 250 participants with retinal disease will be enrolled and up to 120 healthy volunteers will be enrolled.
説明
- INCLUSION CRITERIA:
- Participant must be five years of age or older.
- Participant (or legal guardian) must understand and sign the protocol s informed consent document.
- Participant must be able to cooperate with the testing required for this study.
For Participants with retinal disease only:
- Participant must have retinal disease, defined as evidence of loss of retinal dysfunction and/or degeneration as established by standard clinical methods including perimetry, ERG and imaging.
- Participant must have a measurable visual acuity.
For Healthy Volunteers only:
-Participant must have visual acuity of 20/20 or better, with or without correction (e.g., glasses or contact lens) in at least one eye.
EXCLUSION CRITERIA:
-Participant with changes in pre-retinal media sufficient to obscure a view of the retina.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:CASE_CONTROL
- 時間の展望:CROSS_SECTIONAL
コホートと介入
グループ/コホート |
|---|
|
Affected
Participants with retinal disease |
|
Unaffected
Healthy volunteers |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The primary outcomes for this study are to establish normal ranges for the kinetics of dark adaptation and dark-adapted retinal sensitivity for the fundus guided and non-guided perimeters and for RF hyperacuity on the Display++.
時間枠:ongoing, up to 10 visits in 5 years
|
The primary outcomes for this study are to establish normal ranges for the kinetics of dark adaptation and dark-adapted retinal sensitivity for the fundus guided and non-guided perimeters and for RF hyperacuity on the Display++. |
ongoing, up to 10 visits in 5 years
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Secondary outcomes will be to examine changes in the kinetics of dark adaptation and dark-adapted retinal sensitivity, and scotopic and photopic RF hyperacuity in participants with retinal disease.
時間枠:ongoing, up to four visits in 5 years
|
Secondary outcomes will be to examine changes in the kinetics of dark adaptation and dark-adapted retinal sensitivity, and scotopic and photopic RF hyperacuity in participants with retinal disease. |
ongoing, up to four visits in 5 years
|
協力者と研究者
捜査官
- 主任研究者:Brett G Jeffrey, Ph.D.、National Eye Institute (NEI)
出版物と役立つリンク
一般刊行物
- Birch DG, Wen Y, Locke K, Hood DC. Rod sensitivity, cone sensitivity, and photoreceptor layer thickness in retinal degenerative diseases. Invest Ophthalmol Vis Sci. 2011 Sep 9;52(10):7141-7. doi: 10.1167/iovs.11-7509.
- Jackson GR, Owsley C, Curcio CA. Photoreceptor degeneration and dysfunction in aging and age-related maculopathy. Ageing Res Rev. 2002 Jun;1(3):381-96. doi: 10.1016/s1568-1637(02)00007-7.
- Massof RW, Finkelstein D. Rod sensitivity relative to cone sensitivity in retinitis pigmentosa. Invest Ophthalmol Vis Sci. 1979 Mar;18(3):263-72.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (推定)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。