Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Función mediada por bastones y conos en la enfermedad de la retina

20 de noviembre de 2026 actualizado por: National Eye Institute (NEI)

Background:

Retinal diseases cause the loss of rod and cone photoreceptors. Symptoms include vision loss and night blindness. Researchers want to learn about rod and cone function in healthy people and people with retinal disease. They want to know if how well a person sees in the dark can test the severity of retinal disease.

Objectives:

To find out if how well a person sees in the dark can test the severity of retinal disease. To find out if this can help detect retinal disease and track its changes.

Eligibility:

People ages 5 and older with:

Retinal disease OR

20/20 vision or better with or without correction in at least one eye

Design:

Participants will be screened with medical and eye history and eye exam. Those with retinal disease will also have:

Eye imaging: Drops dilate the eye and pictures are taken of it.

Visual field testing: Participants look into a bowl and press a button when they see light.

Electroretinogram (ERG): An electrode is taped to the forehead. Participants sit in the

dark with their eyes patched for 30 minutes. Then they get numbing drops and contact

lenses. Participants watch lights while retina signals are recorded.

Visit 1 will be 3-8 hours. Participants will have up to 6 more visits over 6-12 months. Visits include:

Eye exam and imaging

Time course of dark adaptation: Participants view a background light for 5 minutes then

push a button when they see colored light.

Dark adapted sensitivity: Participants sit in the dark for 45 minutes. They push a button when

they see colored light.

For participants with retinal disease, ERG and visual field testing

...

Descripción general del estudio

Descripción detallada

Objective: The objective of this protocol is to investigate local changes in rod and cone photoreceptor function across the retina in healthy volunteers and participants with retinal disease.

Study Population: Up to 250 healthy volunteers and 250 participants, age five or older, with retinal disease.

Design: This single-center, observational, case-control study will be comprised of three related Aims that assess rod and cone function with commercial perimeters and/or a commercial Cambridge Research Systems computer monitor (Display++) specialized for displaying stimuli at low light intensities. For Aim 1 the normal retinal sensitivity ranges will be established for both fundus-guided and non-guided perimeters. For Aim 2, the normal range for describing the kinetics of dark adaptation following bleaching of retinal rhodopsin will be established for the fundus-guided and non-guided perimeters. For Aim 3, local changes in rod and cone photoreceptor function across the retina in participants with retinal disease will be examined from measurement of the kinetics of dark adaptation, scotopic and photopic retinal sensitivity, and/or Radial Frequency (RF) hyperacuity on the Display++ monitor. Testing may also include patient reported outcome (PRO) questionnaires to assess vision problems under low luminance conditions. For Aim 4, a subset of retinal disease participants (approximately 40) will complete two electroretinogram (ERG) sessions to develop a scaling factor to allow comparison with historical clinical data. The scaling factor will be used in the NEI ophthalmology clinic to account for changes in ERG parameters in patients tested using the current system compared to older clinical results.

Outcome Measures: The primary outcome for this study is to establish normal ranges for A) the kinetics of dark adaptation (time), B) retinal sensitivity (dB) for the fundus-guided and non-guided perimeters, and C) RF hyperacuity on the Display++ monitor. The secondary outcomes will be to examine changes in the kinetics of dark adaptation, scotopic and photopic retinal sensitivity, and/or RF hyperacuity in participants with retinal disease and potentially correlate these clinical measures with patients self-reported evaluation of their vision under low luminance conditions. An exploratory outcome will be to define a scaling factor for ERGs recorded with the RM electrode on the MonCV electrophysiology systems (MonCvONE and MonPackONE, Metrovision France) with the ERG data previously recorded with the Burian-Allen (BA) electrode on the commercial UTAS(TM) electrophysiology system.

Tipo de estudio

De observación

Inscripción (Estimado)

500

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Daniel W Claus, R.N.
  • Número de teléfono: (301) 451-1621
  • Correo electrónico: daniel.claus@nih.gov

Copia de seguridad de contactos de estudio

  • Nombre: Brett G Jeffrey, Ph.D.
  • Número de teléfono: (301) 402-2391
  • Correo electrónico: jeffreybg@mail.nih.gov

Ubicaciones de estudio

    • Maryland
      • Bethesda, Maryland, Estados Unidos, 20892
        • Reclutamiento
        • National Institutes of Health Clinical Center

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

5 años a 100 años (Niño, Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

Up to 250 participants with retinal disease will be enrolled and up to 120 healthy volunteers will be enrolled.

Descripción

  • INCLUSION CRITERIA:
  • Participant must be five years of age or older.
  • Participant (or legal guardian) must understand and sign the protocol s informed consent document.
  • Participant must be able to cooperate with the testing required for this study.

For Participants with retinal disease only:

  • Participant must have retinal disease, defined as evidence of loss of retinal dysfunction and/or degeneration as established by standard clinical methods including perimetry, ERG and imaging.
  • Participant must have a measurable visual acuity.

For Healthy Volunteers only:

-Participant must have visual acuity of 20/20 or better, with or without correction (e.g., glasses or contact lens) in at least one eye.

EXCLUSION CRITERIA:

-Participant with changes in pre-retinal media sufficient to obscure a view of the retina.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: CASE_CONTROL
  • Perspectivas temporales: CROSS_SECTIONAL

Cohortes e Intervenciones

Grupo / Cohorte
Affected

Participants with retinal disease

Unaffected

Healthy volunteers

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
The primary outcomes for this study are to establish normal ranges for the kinetics of dark adaptation and dark-adapted retinal sensitivity for the fundus guided and non-guided perimeters and for RF hyperacuity on the Display++.
Periodo de tiempo: ongoing, up to 10 visits in 5 years

The primary outcomes for this study are to establish normal ranges for the kinetics of dark adaptation and dark-adapted retinal sensitivity for the fundus guided and non-guided perimeters and for RF hyperacuity on the Display++.

ongoing, up to 10 visits in 5 years

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Secondary outcomes will be to examine changes in the kinetics of dark adaptation and dark-adapted retinal sensitivity, and scotopic and photopic RF hyperacuity in participants with retinal disease.
Periodo de tiempo: ongoing, up to four visits in 5 years

Secondary outcomes will be to examine changes in the kinetics of dark adaptation and dark-adapted retinal sensitivity, and scotopic and photopic RF hyperacuity in participants with retinal disease.

ongoing, up to four visits in 5 years

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Brett G Jeffrey, Ph.D., National Eye Institute (NEI)

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

24 de marzo de 2016

Finalización primaria (Estimado)

30 de diciembre de 2029

Finalización del estudio (Estimado)

30 de diciembre de 2029

Fechas de registro del estudio

Enviado por primera vez

28 de noviembre de 2015

Primero enviado que cumplió con los criterios de control de calidad

28 de noviembre de 2015

Publicado por primera vez (Estimado)

1 de diciembre de 2015

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

23 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

20 de noviembre de 2026

Última verificación

18 de agosto de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir