Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation
Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation a Randomized Clinical Trial
Hypothesis The investigators hypothesis that fixation of mandibular angle fractures using a 3D titanium miniplate will provide better occlusal bite force than intraoral fixation using the standard two-plate technique.
The investigators expect that this method will facilitate a faster recovery time for participants to regain baseline occlusion force.
調査の概要
状態
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Cairo、エジプト
- Faculty of oral and dental medicine ,cairo university , oral and maxillodical department
-
-
参加基準
適格基準
就学可能な年齢
- 大人
健康ボランティアの受け入れ
説明
Inclusion Criteria:
• Age from 20 to 50years.
- Male .
- Patients with mandibular angle fractures.
Exclusion Criteria:
• Patients with contraindication to general anesthesia
- Patients with comminuted angle fractures.
- Patients with relevant systemic diseases contraindicating surgery or affecting bone healing.
- Patients with infected condyle and coronoid fractures.
- Gun-shot injuries.
- Edentulous fractures.
- Pathological fractures.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:トリプル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:fixation using standard Two plate titanium.
Intervention Name: Two Standard plat titanium system . Intervention Type: Device Assigned Intervention: Fixation using two titanium miniplates. The first plate is placed at the inferior border of the mandible from the buccal side, fixed with bicortical screws engaging both cortices. The second plate is positioned ~5 mm superior or at the external oblique ridge, fixed with monocortical screws to avoid dental root injury. |
Fixation using two titanium miniplates.
One plate at the inferior border of the mandible with bicortical screws.
Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
他の名前:
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws.
Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line.
Screws placed diagonally first.
他の名前:
|
|
実験的:3D titanium miniplate
Intervention Name: 3D Titanium Miniplate (2.0 mm, 8-hole) Intervention Type: Device Assigned Intervention: Fixation with a single rectangular 2.0 mm 9-hole 3D titanium miniplate. Two diagonally opposite monocortical screws placed first, followed by the remaining two. The plate is contoured with crossbars perpendicular and struts parallel to the fracture line. The upper crossbar is positioned subapically. Fixation is on the lateral cortex or external oblique ridge with proper adaptation. |
Fixation using two titanium miniplates.
One plate at the inferior border of the mandible with bicortical screws.
Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
他の名前:
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws.
Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line.
Screws placed diagonally first.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Occlusal force
時間枠:first day surgery , second visit 30 days , the last visit 120 days. .
|
use bite force measurement device .
make patient bite to muser the force (, newton unit).
|
first day surgery , second visit 30 days , the last visit 120 days. .
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
maximal incisal opening.
時間枠:first day surgery , second visit 30 days , the last visit 120 days. .
|
Ask the patient to open their mouth as wide as possible without feeling pain. Using a ruler or caliper, measure the vertical distance between the incisal edge of the upper central incisor and the incisal edge of the lower central incisor |
first day surgery , second visit 30 days , the last visit 120 days. .
|
|
Patient satisfaction
時間枠:first day surgery , second visit 30 days , the last visit 120 days. .
|
will be measured on a visual analogue scale (VAS) with zero being unsatisfied and ten being satisfied and happy .
|
first day surgery , second visit 30 days , the last visit 120 days. .
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。