- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07574554
Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation
Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation a Randomized Clinical Trial
Hypothesis The investigators hypothesis that fixation of mandibular angle fractures using a 3D titanium miniplate will provide better occlusal bite force than intraoral fixation using the standard two-plate technique.
The investigators expect that this method will facilitate a faster recovery time for participants to regain baseline occlusion force.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Cairo, Egypt
- Faculty of oral and dental medicine ,cairo university , oral and maxillodical department
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
• Age from 20 to 50years.
- Male .
- Patients with mandibular angle fractures.
Exclusion Criteria:
• Patients with contraindication to general anesthesia
- Patients with comminuted angle fractures.
- Patients with relevant systemic diseases contraindicating surgery or affecting bone healing.
- Patients with infected condyle and coronoid fractures.
- Gun-shot injuries.
- Edentulous fractures.
- Pathological fractures.
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Trippel
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Aktiv komparator: fixation using standard Two plate titanium.
Intervention Name: Two Standard plat titanium system . Intervention Type: Device Assigned Intervention: Fixation using two titanium miniplates. The first plate is placed at the inferior border of the mandible from the buccal side, fixed with bicortical screws engaging both cortices. The second plate is positioned ~5 mm superior or at the external oblique ridge, fixed with monocortical screws to avoid dental root injury. |
Fixation using two titanium miniplates.
One plate at the inferior border of the mandible with bicortical screws.
Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Andre navn:
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws.
Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line.
Screws placed diagonally first.
Andre navn:
|
|
Eksperimentell: 3D titanium miniplate
Intervention Name: 3D Titanium Miniplate (2.0 mm, 8-hole) Intervention Type: Device Assigned Intervention: Fixation with a single rectangular 2.0 mm 9-hole 3D titanium miniplate. Two diagonally opposite monocortical screws placed first, followed by the remaining two. The plate is contoured with crossbars perpendicular and struts parallel to the fracture line. The upper crossbar is positioned subapically. Fixation is on the lateral cortex or external oblique ridge with proper adaptation. |
Fixation using two titanium miniplates.
One plate at the inferior border of the mandible with bicortical screws.
Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Andre navn:
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws.
Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line.
Screws placed diagonally first.
Andre navn:
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Occlusal force
Tidsramme: first day surgery , second visit 30 days , the last visit 120 days. .
|
use bite force measurement device .
make patient bite to muser the force (, newton unit).
|
first day surgery , second visit 30 days , the last visit 120 days. .
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
maximal incisal opening.
Tidsramme: first day surgery , second visit 30 days , the last visit 120 days. .
|
Ask the patient to open their mouth as wide as possible without feeling pain. Using a ruler or caliper, measure the vertical distance between the incisal edge of the upper central incisor and the incisal edge of the lower central incisor |
first day surgery , second visit 30 days , the last visit 120 days. .
|
|
Patient satisfaction
Tidsramme: first day surgery , second visit 30 days , the last visit 120 days. .
|
will be measured on a visual analogue scale (VAS) with zero being unsatisfied and ten being satisfied and happy .
|
first day surgery , second visit 30 days , the last visit 120 days. .
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- angle frcture ,Truma
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .