Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation

1 mei 2026 bijgewerkt door: Ahmed jassim Ahmed alsubaya, Cairo University

Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation a Randomized Clinical Trial

Hypothesis The investigators hypothesis that fixation of mandibular angle fractures using a 3D titanium miniplate will provide better occlusal bite force than intraoral fixation using the standard two-plate technique.

The investigators expect that this method will facilitate a faster recovery time for participants to regain baseline occlusion force.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Geschat)

20

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Cairo, Egypte
        • Faculty of oral and dental medicine ,cairo university , oral and maxillodical department

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • • Age from 20 to 50years.

    • Male .
    • Patients with mandibular angle fractures.

Exclusion Criteria:

  • • Patients with contraindication to general anesthesia

    • Patients with comminuted angle fractures.
    • Patients with relevant systemic diseases contraindicating surgery or affecting bone healing.
    • Patients with infected condyle and coronoid fractures.
    • Gun-shot injuries.
    • Edentulous fractures.
    • Pathological fractures.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Verdrievoudigen

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: fixation using standard Two plate titanium.

Intervention Name: Two Standard plat titanium system . Intervention Type: Device

Assigned Intervention:

Fixation using two titanium miniplates. The first plate is placed at the inferior border of the mandible from the buccal side, fixed with bicortical screws engaging both cortices. The second plate is positioned ~5 mm superior or at the external oblique ridge, fixed with monocortical screws to avoid dental root injury.

Fixation using two titanium miniplates. One plate at the inferior border of the mandible with bicortical screws. Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Andere namen:
  • two Titanium Miniplates Fixation ,Dual Miniplate Fixation ,Conventional Two-Plate Technique.
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws. Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line. Screws placed diagonally first.
Andere namen:
  • Single 3D Titanium Plate, 2.0 mm Thickness, 6-Hole Rectangular 6-Hole ,3D Titanium Miniplate 3D Contoured Titanium Plate, 2.0 mm, 6-Hole
Experimenteel: 3D titanium miniplate

Intervention Name: 3D Titanium Miniplate (2.0 mm, 8-hole) Intervention Type: Device

Assigned Intervention:

Fixation with a single rectangular 2.0 mm 9-hole 3D titanium miniplate. Two diagonally opposite monocortical screws placed first, followed by the remaining two. The plate is contoured with crossbars perpendicular and struts parallel to the fracture line. The upper crossbar is positioned subapically. Fixation is on the lateral cortex or external oblique ridge with proper adaptation.

Fixation using two titanium miniplates. One plate at the inferior border of the mandible with bicortical screws. Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Andere namen:
  • two Titanium Miniplates Fixation ,Dual Miniplate Fixation ,Conventional Two-Plate Technique.
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws. Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line. Screws placed diagonally first.
Andere namen:
  • Single 3D Titanium Plate, 2.0 mm Thickness, 6-Hole Rectangular 6-Hole ,3D Titanium Miniplate 3D Contoured Titanium Plate, 2.0 mm, 6-Hole

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Occlusal force
Tijdsspanne: first day surgery , second visit 30 days , the last visit 120 days. .
use bite force measurement device . make patient bite to muser the force (, newton unit).
first day surgery , second visit 30 days , the last visit 120 days. .

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
maximal incisal opening.
Tijdsspanne: first day surgery , second visit 30 days , the last visit 120 days. .

Ask the patient to open their mouth as wide as possible without feeling pain.

Using a ruler or caliper, measure the vertical distance between the incisal edge of the upper central incisor and the incisal edge of the lower central incisor

first day surgery , second visit 30 days , the last visit 120 days. .
Patient satisfaction
Tijdsspanne: first day surgery , second visit 30 days , the last visit 120 days. .
will be measured on a visual analogue scale (VAS) with zero being unsatisfied and ten being satisfied and happy .
first day surgery , second visit 30 days , the last visit 120 days. .

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 januari 2025

Primaire voltooiing (Geschat)

1 juni 2026

Studie voltooiing (Geschat)

30 november 2026

Studieregistratiedata

Eerst ingediend

10 juni 2025

Eerst ingediend dat voldeed aan de QC-criteria

1 mei 2026

Eerst geplaatst (Werkelijk)

8 mei 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

8 mei 2026

Laatste update ingediend die voldeed aan QC-criteria

1 mei 2026

Laatst geverifieerd

1 april 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .