이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

The Effect of Varying Brightness on Palpebral Aperture

2022년 1월 14일 업데이트: University of Edinburgh

The Effect of Varying Brightness Levels on Palpebral Aperture and the Point of Orbicularis Engagement Using EEG Signalling.

We aim to establish the point at which glare from bright lights begins to engage our eyelids - causing us to "squint". We will be using a video camera with an LED ring light around it facing the volunteer and we will record the eyelid position as the light brightness is increased gradually. Many studies have looked at the effect glare has on a person through qualitative questionnaires but few have been able to quantify this.

연구 개요

상태

모집하지 않고 적극적으로

정황

개입 / 치료

상세 설명

Our study will aim to establish the point of orbicularis engagement based on luminous intensity Murray et al. created an Ocular Stress Monitor to see if the contracture of the muscles on the eyelid indicative of pain as a light source was increased in luminosity 8 Our study will go one step further by using video technology and a portable EEG machine to detect the pulses of lid contracture as luminosity of a ring light i s increased incrementally. An advanced calibrated datalogging LED light meter will simultaneously record the level of brightness to establish at which point the spike in EEG occurs. Screenshots from the video recording will be taken and accurate MRD1 measurements can be taken at the point of orbicular i s engagement.

The scientific justification for this research question is twofold We wish to establish the threshold at which orbicularis engages such that palpebral aperture and MRD measurements are altered. This is relevant to the technique of taking these measurements in the clinical environment and the light intensity at which these measurements are taken. We wish to establish the light intensity which should not be exceeded to take these measurements. As photography becomes increasingly used in oculoplastic s clinics we envisage palpebral aperture and MRD1 measurements being performed digitally rather than manually These measurements are relevant to pre operative and post operative imaging, and surgical planning. Furthermore, our results maybe applicable more widely to industry, for example vehicle headlights, bicycle lights, camera flash, workplace lighting.

Reference: Murray I, Plainis S, Carden D. The ocular stress monitor: a new device for measuring discomfort glare. Lighting Research Technology. 2002;34(3):231 239.

연구 유형

중재적

등록 (예상)

40

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • London, 영국, NW3 2QY
        • Ophthalmology, Royal Free Hospital

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Aged between 18 and 65 years of age
  • A member of the Royal Free NHS trust

Exclusion Criteria:

  • No known ocular pathology
  • No lid problems/ptosis or previous lid surgery
  • No contact lenses in for duration of experiment
  • No pseudophakia
  • No neurological disease

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 기초 과학
  • 할당: 무작위화되지 않음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: The observation of eyelid positioning and EEG pulses from the eyelid on increasing brightness
In a dimly lit room the participant will place their chin on the slit lamp We will use t he optimal background illumination used for Humphrey and Goldman visual fields which is 31.5 apostilbs (10Lux 9 They will look into the video camera placed 50cm away, which will have a dimmable remote control ring light fitted around it. The part icipant will have a reference measure taped to the headrest and three electrodes placed around the right eye. One active electrode place on the lower lid and one reference electrode towards the temporal margin and one earth electrode placed on the forehead The brightness of the ring light will be increased via the dimmer switch whilst simultaneously recording the lux with the LED light meter. The participant will be advised t o close their eyes if the brightness becomes uncomfortable and this will be repea ted three times.
Up to 30 seconds, three times, looking into a video camera as glare is incrementally increased.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
The point at which the eyelid begins to contract under what brightness level
기간: All carried out within a 2 week period
Using a light meter, ring light, and EEG machine
All carried out within a 2 week period

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

협력자

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2022년 1월 14일

기본 완료 (예상)

2022년 2월 21일

연구 완료 (예상)

2022년 2월 21일

연구 등록 날짜

최초 제출

2022년 1월 14일

QC 기준을 충족하는 최초 제출

2022년 1월 14일

처음 게시됨 (실제)

2022년 1월 27일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2022년 1월 27일

QC 기준을 충족하는 마지막 업데이트 제출

2022년 1월 14일

마지막으로 확인됨

2022년 1월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • 1062/RD

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

IPD 계획 설명

Data findings will be presented to the department, all those involved at the next departmental meeting.

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .