이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Advanced Technology for Myopia Control in Children and Young Adults (MyopiaTech)

2026년 6월 20일 업데이트: Dr Memoona Arshad, University of Faisalabad

Role of Advanced Technological Approaches for Myopia Control in Myopic Patients: A Randomized Controlled Trial of Lenslet Spectacles vs. Violet Excitation Filter Glasses vs. Single Vision Lenses

Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses (wavelength 420 nm) and Single vision lenses for controls. The study enrolled 90 participants aged 8 to 20 years from schools and universities in Faisalabad, Pakistan. Participants were randomly assigned to one of three groups: lenslet spectacles, violet filter glasses, or single vision lenses (control group). Visual acuity, contrast sensitivity, Spherical Equivalent and axial length were measured at the start and again after 3, 6, and 9 months and one follow up after cessation of treatment. The study aimed to determine whether these advanced technologies can effectively slow myopia progression compared to standard glasses, providing head-to-head evidence on emerging and established optical interventions for myopia control.

연구 개요

상태

완전한

정황

개입 / 치료

상세 설명

This is a randomized controlled trial (RCT) with three parallel groups. The study was conducted at schools and the Universities in Faisalabad, Pakistan. The total study duration was almost one year (July 2025 to May 2026), with each participant undergoing atleast 3 months of active treatment with 3 follow ups. The sample size was 30 participants per group (total N=90), after drop put of patients, calculated using G*Power (repeated measures ANOVA, 3 groups × 4 time points, medium effect size f=0.25, α=0.05, power=0.8). Simple random sampling was used, with participants allocated to groups using an online research randomizer. Inclusion criteria: axial myopia (high, moderate, or severe), age 8-20 years, both genders, willingness to wear glasses. Exclusion criteria:

other ametropia, contact lens users, prior myopia treatment, ocular or systemic disease, ocular surgery, non-cooperative patients. Lenslet group: Essilor Stellest spectacles with Highly Aspheric Lenslet Target technology, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating; worn all waking hours. Violet filter group: plastic lenses with 420nm violet excitation filter; worn 3 hours daily (11 AM to 2 PM) to align with circadian rhythm. Control group: single vision lenses (refractive index 1.56). Primary outcome measures: change in axial length (measured by ocular biometer) and change in cycloplegic refraction. Secondary outcome measures: visual acuity (LogMAR chart), contrast sensitivity (Vistech chart). Follow-up assessments at 3, 6, and 9 months. Statistical analysis: repeated measures Linear mixed model using SPSS version 26 to compare within-group and between-group changes.

연구 유형

중재적

등록 (실제)

90

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Punjab Province
      • Faisalābad, Punjab Province, 파키스탄, 3800
        • The University of Faisalabad

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 어린이
  • 성인

건강한 자원 봉사자를 받아들입니다

아니

설명

Inclusion Criteria:

  • Diagnosis of axial myopia (high, moderate, or severe)
  • Age between 8 and 20 years (inclusive)
  • Male or female
  • Willingness to wear prescribed glasses as instructed
  • Willingness to attend all follow-up visits (3, 6, and 9 months)
  • Written informed consent from participant or parent/guardian for minors

Exclusion Criteria:

  • Any ametropia other than axial myopia (e.g., hyperopia, astigmatism >1.50D)
  • Current contact lens users
  • Prior or concurrent myopia treatment other than study interventions
  • Any ocular disease (e.g., cataract, glaucoma, retinal disorders)
  • Any systemic disease affecting vision (e.g., diabetes, Marfan syndrome)
  • History of any ocular surgery
  • Allergic or physical intolerance to glasses materials
  • Non-cooperative patients unwilling to comply with study procedures

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Lenslet Spectacles (HALT Technology
Participants receive Essilor Stellest spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) anf violet filter glasses technology. Lenses have 1.6mm thickness, refractive index 1.56, UV 400. Participants are instructed to wear glasses throughout all waking hours for 9 months and for VF atleast 3ours.
The lenslet spectacles are specially designed spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) technology manufactured by Essilor International (Serial Number: 72426930). The lens design includes a clear distance zone in the center with peripheral areas providing single vision correction. Technical specifications: 5H green covering, multi-dimensional pattern, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating. Participants are instructed to wear the spectacles throughout all waking hours. Each participant receives a new pair at baseline. No adjustments are made during the 12-month treatment period unless vision changes require prescription update.
실험적: Violet Excitation Filter Glasses
Participants receive prescription glasses with violet excitation filter (420 nm wavelength, CR-39 material). Participants are instructed to wear glasses for 3 hours daily (11 AM to 2 PM) for 12 months to align with circadian rhythm.
The violet excitation filter glasses are prescription glasses incorporating a violet light filter with wavelength 420 nm (range 360-420 nm). Material: CR-39. Filter intensity: 700 nm. Wavelength verified using spectrophotometer (standard error ±0.1 to 1 nm). Participants are instructed to wear the glasses for 3 hours daily, specifically from 11 AM to 2 PM, to optimize impact on circadian rhythm while avoiding disruption of sleep patterns. Each participant receives a new pair at baseline. The filter is integrated into the prescription lenses.
활성 비교기: Single Vision Lenses
Participants receive standard single vision spectacle lenses (SVS index 1.56). Participants are instructed to wear glasses throughout all waking hours for 12 months.
Standard single vision spectacle lenses (SVS index 1.56) with no myopia control features. These are conventional prescription glasses that correct refractive error but do not incorporate lenslet technology or violet filtering. Participants are instructed to wear the glasses throughout all waking hours. Each participant receives a new pair at baseline.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Change in Axial Length
기간: Baseline, Month 3, Month 6, Month 9
Axial length (mm) measured using an A-SCAN biometer (Scanmate 677AB). The measurement represents the distance from the corneal apex to the retinal pigment epithelium. Three measurements are taken for each eye and averaged. This is a continuous anatomical measurement with no theoretical minimum or maximum score. Higher values indicate greater ocular elongation, which is associated with worsening myopia progression.
Baseline, Month 3, Month 6, Month 9
Change in Cycloplegic Refraction
기간: Baseline, Month 3, Month 6, Month 9
Cycloplegic spherical equivalent refraction (SER), measured in diopters (D) using retinoscopy (Welch Allyn) after cycloplegia. SER is calculated as sphere + (cylinder/2). This is a continuous measurement with no theoretical minimum or maximum value. A decrease in SER (more negative values) reflects progression of myopia, while an increase in SER (less negative or more positive values) reflects reduced myopia or a shift toward hyperopia.
Baseline, Month 3, Month 6, Month 9

2차 결과 측정

결과 측정
측정값 설명
기간
Change in Visual Acuity
기간: Baseline, Month 3, Month 6, Month 9
Visual acuity measured using the Logarithm of the Minimum Angle of Resolution (LogMAR) Visual Acuity Chart (Precision Vision) at 4 m, 2 m, and 1 m. LogMAR scores typically range from approximately -0.30 (better visual acuity) to 1.60 (poorer visual acuity), although values may extend beyond these limits. Lower scores represent better visual acuity outcomes, and higher scores represent worse visual acuity outcomes.
Baseline, Month 3, Month 6, Month 9
Change in Contrast Sensitivity
기간: Baseline, Month 3, Month 6, Month 9
Contrast sensitivity measured using the Vistech Contrast Sensitivity Test Chart (Precision Vision) at 1 meter. Contrast sensitivity scores are reported in log contrast sensitivity units and typically range from 0.00 to approximately 2.25. Higher scores represent better contrast sensitivity and visual performance, while lower scores represent poorer contrast sensitivity and visual performance.
Baseline, Month 3, Month 6, Month 9

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

유용한 링크

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2025년 7월 1일

기본 완료 (실제)

2026년 5월 30일

연구 완료 (실제)

2026년 6월 6일

연구 등록 날짜

최초 제출

2026년 6월 8일

QC 기준을 충족하는 최초 제출

2026년 6월 8일

처음 게시됨 (실제)

2026년 6월 12일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 6월 25일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 6월 20일

마지막으로 확인됨

2026년 6월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • TUF/IRB/ 38 /25

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .