이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Wearable Assessment of Thoracic, Cardiac Health and Exercise Performance Trial Prospective (WATCH-XP)

2026년 6월 16일 업데이트: Wong Chun Ka, The University of Hong Kong

Wearable Assessment of Thoracic, Cardiac Health and Exercise Performance Trial Prospective (WATCH-XP)

Wearable health technology, particularly smartwatches, has revolutionized personal health monitoring by enabling continuous, non-invasive tracking of various physiological parameters. The potential applications of these devices in cardiology are extensive, but it is crucial to validate their accuracy against established medical-grade devices.

The Apple Watch Series 9 (Apple, USA) exemplifies the capabilities of modern smartwatches, offering a wide range of health tracking features. These include heart rate monitoring, detection of irregular heart rhythms suggestive of atrial fibrillation, electrocardiogram recording, blood oxygen level measurement, and comprehensive mobility metrics (including VO2 max, six-minute walk distance, walking speed, step length, double support time, and walking asymmetry). Many of these parameters are highly relevant for cardiovascular patients, potentially aiding in disease progression monitoring and adverse event prediction. However, there is a lack of comprehensive validation studies for these devices in specific cardiovascular disease populations.

This investigator-initiated, prospective observational study will consist of two phases: a training phase which involves 50 participants and a prospective validation phase which involves 20 participants. The study aims to validate smartwatch-based assessments using medical-grade devices and techniques. The study will focus on adult patients with congenital heart disease, pulmonary hypertension, heart failure, and coronary artery disease, as well as athletes undergoing cardiovascular assessment. By comparing smartwatch data with established clinical measurements, we seek to determine the reliability and potential clinical utility of these wearable devices in diverse cardiovascular contexts. Anonymized smartwatch data collected during the two phases will be published to a publicly registry to facilitate further research. This research will help bridge the gap between consumer-grade wearable technology and clinical practice in cardiology.

연구 개요

상태

아직 모집하지 않음

정황

개입 / 치료

상세 설명

This study is investigator-initiated, prospective observational study and will consist of two phases: a training phase and a prospective validation phase.

Training Phase (First Phase) 50 participants will undergo comprehensive baseline assessments and continuous physiological monitoring with the smartwatch. Data collected during this phase will be anonymized and exported to a public open-source training model.

At Visit 1 of the first phase, Comprehensive demographic and clinical data will be collected from each participant, Clinical Management System (CMS), Electronic Patient Record (ePR), and Clinical Data Analysis and Reporting System (CDARS) of the Hospital Authority in Hong Kong. This will include age, sex, height, weight, body mass index, and detailed medical history focusing on cardiovascular conditions. Information about current medications and smoking status will also be recorded. Additionally, participants will undergo a baseline clinical examination, including blood pressure measurement, heart rate, and a 12-lead electrocardiogram.

VO2max Participants will undergo a conventional cardiopulmonary exercise test (CPX) to determine their maximal oxygen uptake (VO2max) at Visit 1. This test will be conducted in a controlled clinical setting under the supervision of cardiologists. Participants will exercise on a treadmill while their respiratory gas exchange is measured using a metabolic cart. The exercise intensity will be gradually increased until the participant reaches volitional exhaustion or predetermined safety criteria are met. The highest oxygen uptake value achieved during the test will be recorded as the VO2max. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment. This gold-standard measurement will serve as the reference for validating the smartwatch's continuous VO2max estimation.

6-Minute walk distance The 6-minute walk distance will be assessed in a hospital setting at Visit 2 of the first phase under the supervision of a research staff. Participants will be instructed to walk as far as possible in six minutes along a predetermined course, typically a straight hallway. The total distance walked will be measured and recorded. During the test, the research nurse will monitor the participant's heart rate, blood oxygen saturation, and perceived exertion at regular intervals. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment.

Oxygen saturation During the follow-up period of the first phase, participants will be provided with a medical-grade pulse oximeter for home use. They will be instructed to measure their oxygen saturation once daily throughout the one-week study period. Measurements should be taken at approximately the same time each day, preferably in the morning after waking and before any strenuous activity. Participants will record their oxygen saturation readings in a provided log. These daily measurements will serve as reference points for validating the continuous oxygen saturation data collected by the smartwatch.

Prospective Validation Phase (Second Phase) 20 participants will undergo similar assessments, with the primary aim of validating the smartwatch's measurements against medical-grade devices. Data collected during this phase also will be anonymized and exported to a public open-source training model.

At the Visit of the second phase, Comprehensive demographic and clinical data will be collected from each participant, Clinical Management System (CMS), Electronic Patient Record (ePR), and Clinical Data Analysis and Reporting System (CDARS) of the Hospital Authority in Hong Kong. This will include age, sex, height, weight, body mass index, and detailed medical history focusing on cardiovascular conditions. Information about current medications and smoking status will also be recorded. Additionally, participants will undergo a baseline clinical examination, including blood pressure measurement, heart rate, and a 12-lead electrocardiogram.

VO2max Participants will undergo a conventional cardiopulmonary exercise test (CPX) to determine their maximal oxygen uptake (VO2max) at Visit 1. This test will be conducted in a controlled clinical setting under the supervision of cardiologists. Participants will exercise on a treadmill while their respiratory gas exchange is measured using a metabolic cart. The exercise intensity will be gradually increased until the participant reaches volitional exhaustion or predetermined safety criteria are met. The highest oxygen uptake value achieved during the test will be recorded as the VO2max. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment. This gold-standard measurement will serve as the reference for validating the smartwatch's continuous VO2max estimation.

연구 유형

관찰

등록 (추정된)

20

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Chun Ka Wong
  • 전화번호: +852 2255 3111
  • 이메일: wongeck@hku.hk

연구 장소

      • Hong Kong, 홍콩
        • Department of Medicine, Queen Mary Hospital
        • 연락하다:

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

샘플링 방법

비확률 샘플

연구 인구

Patients having adult congenital heart disease or pulmonary hypertension, heart failure or coronary artery disease, or are athletes undergoing cardiovascular assessment

설명

Inclusion Criteria:

  • Age 20 to 70 years old
  • Ability to provide informed consent
  • History of the following cardiovascular conditions:
  • Adult congenital heart disease
  • Pulmonary hypertension
  • Heart failure
  • Coronary artery disease
  • Athletes undergoing cardiovascular assessment

Exclusion Criteria:

  • Contraindication for undergoing physical exertion including cardio-pulmonary exercise testing (CPX) and 6-minute walk test (6MWT)
  • Pregnancy
  • Known allergy to components of the investigational product

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
WatchXP
Participants will wear the investigational smartwatch (Apple Watch Series 9) concurrently for pre- and post-SaO2 and VO2max assessment during cardiopulmonary exercise test at the visit.
Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Correlation between CPX VO2max and smartwatch parameters (virtual VO2 max, physical activity parameters)
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
VO2 max (ml/min/kg) concurrently measured with a medical-grade device and a smartwatch which has virutal VO2 max and physical activity parameters as assessed during treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment

2차 결과 측정

결과 측정
측정값 설명
기간
Correlation between VO2 max (ml/min/kg) obtained using medical-grade device and smartwatch
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
VO2 max (ml/min/kg) obtained using medical-grade device and smartwatch during supervised treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment
Correlation between SaO2 (%) obtained using medical-grade device and smartwatch
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
SaO2 (%) obtained using medical-grade device and smartwatch during supervised treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment
SaO2 (%) measured by the smartwatch
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
SaO2 (%) measured by the smartwatch during supervised treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment
SaO2 (%) in participants with severe disease and participants with mild disease
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
SaO2 (%) in participants with severe versus mild disease during supervised treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment
Novel markers or patterns
기간: During treadmill exercise in the day of recruitment and concurrently baseline assessment
Novel markers or patterns indicative of disease severity or predictive of adverse events as assessed during supervised treadmill exercise
During treadmill exercise in the day of recruitment and concurrently baseline assessment

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 8월 1일

기본 완료 (추정된)

2027년 12월 31일

연구 완료 (추정된)

2028년 12월 31일

연구 등록 날짜

최초 제출

2026년 6월 16일

QC 기준을 충족하는 최초 제출

2026년 6월 16일

처음 게시됨 (실제)

2026년 6월 23일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 6월 23일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 6월 16일

마지막으로 확인됨

2026년 6월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • WATCH-XP

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

예

미국에서 제조되어 미국에서 수출되는 제품

예

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .