AI-Assisted Cholecystectomy Study
AI-Assisted Cholecystectomy With Laparoscopic Surgical Robot: A First-in-Human Study
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
Robotic-assisted surgery provides surgeons with enhanced dexterity, stable three-dimensional visualization, and improved ergonomics for minimally invasive procedures. However, despite these technological advances, complex robotic operations remain cognitively demanding and highly coordinated. In addition to controlling the primary operative instruments, surgeons are required to manage auxiliary tasks such as tissue retraction, maintenance of surgical exposure, and coordination of multiple robotic arms. These auxiliary tasks often require frequent switching between control modes, manual adjustments, or verbal coordination with clinical assistants, which may interrupt surgical flow and increase cognitive workload.
In current clinical practice, maintaining stable and optimal exposure of the surgical field is essential for safe dissection and precise manipulation. Elective robotic or laparoscopic cholecystectomy is a standardized and well-established surgical procedure that involves repetitive and well-defined sub-tasks such as tissue retraction, exposure adjustment, and cystic duct and artery clipping. During this procedure, surgeons must repeatedly adjust retraction direction and tension in response to anatomical variation, tissue deformation, and procedural progression. These adjustments are commonly performed by manually controlling an additional robotic arm or by communicating with an assistant surgeon. Such workflows may divert attention from the primary operative task and increase the risk of inefficiency or distraction, particularly during delicate dissection near critical anatomical structures.
To address the challenges associated with auxiliary task management in robotic surgery, we propose a novel voice-assisted automated "third hand" system for supervised surgical assistance. Recent advances in artificial intelligence, robotic perception, and natural language processing have enabled the development of interactive systems capable of understanding spoken commands and executing structured actions in real time. Prior work suggests that voice-based interaction can be feasibly applied in human-machine and human-robot collaboration, indicating its potential as a hands-free control interface [1,2]. At the same time, progress in task-specific robotic control has made it increasingly feasible to deploy limited, well-defined automation under continuous human supervision. Together, these developments create opportunities for designing intelligent assistive systems that support surgical workflow while preserving surgeon authority and responsibility.
The proposed system integrates a natural language interface with task-specific robotic control to enable surgeons to verbally command and adjust a dedicated robotic arm responsible for tissue retraction, exposure maintenance, and selected repetitive actions. Through predefined motion constraints, force limits, and continuous monitoring, the system is designed to function as an assistive tool rather than an autonomous decision-making agent. The surgeon remains fully responsible for procedural planning and execution and may interrupt or override automated actions at any time. The research team has successfully undergone multiple pre-clinical trials including ex-vivo porcine, live porcine as well as cadaveric procedures, confirming the safety of the AI system. (Refer to "Prior Study" section) Elective robotic cholecystectomy provides an appropriate experimental model for evaluating this approach due to its standardized workflow and frequent requirement for dynamic exposure adjustment. By delegating selected auxiliary tasks to an AI-controlled robotic arm while maintaining continuous surgeon supervision, this study enables systematic evaluation of the feasibility, controllability, and safety of limited, task-specific automation. This experiment, therefore, proposes a clinical first-in-human pilot study to evaluate a collaborative surgical framework in which an automated third hand executes constrained sub-tasks under direct surgeon oversight, while voice commands are used to dynamically adjust and coordinate robotic behavior during surgery, without replacing surgeon judgment or decision-making
연구 유형
연구 유형
등록 (추정된)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Hong Kong, 홍콩
- Department of Surgery, Faculty of Medicine, the Chinese University of Hong Kong
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Age >18 years, and
- Body mass index <35kg/m2, and
- Scheduled for elective laparoscopic / robotic cholecystectomy for symptomatic gallstones or gallbladder polyp, and
- American Society of Anesthesiologist (ASA) I-III
Exclusion Criteria:
- Contraindication to general anaesthesia
- Severe concomitant illness that drastically shortens life expectancy or increases risk of therapeutic intervention
- Past history of cholecystitis, liver abscess, Mirizzi syndrome
- Contracted gallbladder or dilated common bile duct on pre-operative imaging
- Known (Child's B or above) liver cirrhosis
- Uncorrectable coagulopathy
- Previous upper abdominal open surgery
- Presence of another malignancy or distant metastasis
- Emergency surgery
- Vulnerable population (e.g. mentally incapacitated or pregnant persons)
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: Robotic Assisted Laparoscopic Cholecystectomy Group
The procedure would be performed as per robotic assisted cholecystectomy with 4-port techniques.
After putting under general anaesthesia, a peri-umbilical camera port will be inserted with open technique, followed by introduction of capnoperitoneum at pressure of 12mmHg.
Three additional working ports will be inserted in the upper abdomen under direct laparoscopic vision.
Docking of Sentire surgical robotic system would then be carried out, with subsequent procedure performed by the surgeon at the console.
The Calot's triangle would be dissected first with identification of cystic duct and artery to achieve the critical view of safety.
After ligation of both cystic artery and duct, the gallbladder would be dissected from the liver bed, and retrieved from the peri-umbilical port site in a plastic bag.
The insertion of abdominal drain would be upon discretion of the operating surgeon.
The entire procedure would follow the important surgical principles in preventing bile duct injury or o
|
Robotics Sentire Surgical System is a software-controlled, electromechanical system designed and approved for surgeons to perform MIS in the thorax and abdomen.
The operating surgeon sits at the surgeon console, views the surgical site in a high resolution three-dimensional stereo viewer, and controls movements of the EndoWrist instruments and the camera using two master controllers and a set of foot pedals.
The vision cart includes the supporting electronic and video processing equipment for the system.
The system utilizes one designated robotic manipulator as an assistive arm dedicated to exposure management and auxiliary task support during surgery.
This assistive arm is configured to operate independently from the primary operative instruments and is assigned specifically for tissue retraction, vessel/duct clipping, and maintenance of the surgical field.
Its motion and interaction with tissue are governed by task-specific control algorithms and predefined safety constraints.
|
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Clinical success rate
기간: 1 day
|
Clinical success refers to completion of the intended cholecystectomy incorporating the AI system without conversion to conventional robot (without AI assistant), laparoscopy, or open surgery, and without intra-operative complication.
|
1 day
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Intraoperative and Postoperative Complications rate
기간: 30 days
|
Safety data will include all intraoperative and postoperative complications occurring within 30 days following surgery.
Complications will be classified according to standard clinical reporting criteria, including the Clavien-Dindo classification of surgical complications.
|
30 days
|
|
Subjective Assessment of System Performance and Controllability
기간: 1 day
|
Subjective performance assessment will be conducted using modified task-specific evaluation forms adapted from validated surgical skill assessment tools.
Evaluation will be conducted by the operating surgeon, assisting surgeon, and an independent evaluator, focusing on exposure stability, retraction effectiveness, precision of positioning, and integration with primary surgical workflow.
|
1 day
|
|
Objective Assessment of System Performance and Controllability
기간: 1 day
|
Objective metrics to be analyzed include:
|
1 day
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (추정된)
기본 완료
연구 완료 (추정된)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
기타 연구 ID 번호
- CRE-2026.237
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .