이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Diagnostic Accuracy of Innovative Photo-Analysis Software in Resin Composite Shade Matching

2026년 7월 15일 업데이트: Ahmed Mohamed Saleh Ali Farrag, Misr University for Science and Technology

In Vivo Diagnostic Accuracy of Innovative Photo-Analysis Software and Digital Spectrophotometer Compared With Visual Technique in Resin Composite Shade Matching

This study aims to assess the agreement between new computer software using dental photographs, digital spectrophotometer and the visual technique, in achieving accurate resin composite shade matching.

연구 개요

상태

모병

정황

개입 / 치료

상세 설명

  • Custom composite resin shade tabs are fabricated and catalogued to serve as reference standards during shade matching.
  • Teeth are professionally cleaned on dental chair using a nylon prophylaxis brush with polishing paste to ensure complete removal of extrinsic stains and to reveal the native tooth color.
  • Participants will be seated on an adjustable chair in an upright posture, with the head oriented perpendicular to the floor and be stabilized by a headrest. The chair will be positioned against a matte white wall adjacent to a clear window to standardize a neutral background and exploit consistent daylight illumination.
  • Patients will be instructed to maintain an upright head posture with the interpupillary line parallel to the floor. All measurements will be performed under daylight, while extraneous light sources and environmental interferences to be minimized.

    • Computer-Assisted Software A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third of the labial crown of either the tooth or shade tabs.

Candidate shades are then quantitatively compared to the region of interest by computing CIEDE2000 color-difference values (ΔE₀₀), which incorporate corrections for lightness, chroma, and hue; the final selected shade is the one yielding the smallest ΔE₀₀.

Where: ΔL', ΔC', ΔH' are the lightness, chroma, and hue differences in the CIEDE2000 framework; SL, SC, SH are weighting functions; kL, kC, kH are parametric factors (set to 1 unless otherwise justified); and RT is the rotation term accounting for interaction between chroma and hue differences.

  • Spectrophotometer assessment A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade. 9
  • Visual Shade Matching Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.

Agreement between their own assessments and between the other assessors' assessments, as well as the extent of their discrepancies, is quantified using kappa test.

연구 유형

중재적

등록 (추정된)

52

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Esraa Esmeail Hussien EEH lecturer, phd holder
  • 전화번호: +201111103836
  • 이메일: dr.esraaism@gmail.com

연구 연락처 백업

  • 이름: Ahmed Saleh Ali ASA Resident doctor, Bachelor degree
  • 전화번호: +201147965014
  • 이메일: ahmed.msaleh@must.edu.eg

연구 장소

    • Giza Governorate
      • Sixth of October, Giza Governorate, 이집트, 12566
        • 모병
        • Misr University for Science and Technology

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인

건강한 자원 봉사자를 받아들입니다

아니

설명

Inclusion Criteria:

  • Age: 18-45 years.
  • Sex: Male or female.
  • General: Cooperative individuals who agree to participate and comply with study visits (written informed consent to be obtained as applicable).
  • Dentition: Presence of sound maxillary incisors that will meet the tooth-level criteria.

Exclusion Criteria:

  • Poor oral hygiene.
  • Severe systemic/medical complications that may contraindicate elective dental care.
  • Pregnancy.
  • Heavy smokers.
  • Xerostomia.
  • Temporomandibular joint disorders.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 특수 증상
  • 할당: 무작위
  • 중재 모델: 크로스오버 할당
  • 마스킹: 더블

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Digital Spectrophotometer
A pre-calibrated spectrophotometer (per manufacturer guidelines) independently measures tooth and shade-tab color. Measurements are reported as CIE L*, a*, b* values. For each tooth-tab combination, the CIEDE2000 color difference (ΔE00) is calculated; the tab yielding the minimal ΔE00 is accepted as the selected shade.

A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third.

활성 비교기: Visual Shade Matching
Under the same conditions (lighting and patient positioning), experienced assessors independently determine the matching shade.

A standardized Computer-assisted photographic shade-matching workflow will be employed using a novel photo-analysis software that first receives the photos and balances each photo to suppress unrealistic colors using a standard gray reference card (WhiBal; Michael Tapes Design), with nominal colorimetric targets of L* =75, a* = 0, b* = 0, will be included in every photograph within the plane of the teeth.

The Photo is firstly captured with a Nikon D3400 DSLR crop-frame camera (Nikon Corp) mounted on a stable tripod to avoid movements during capturing the photo and set the proper angulation and parallelism. All camera parameters will be standardized.

The program establishes a pixel-to-metric conversion scale (cm) from known distances and overlays orthogonal reference axes to fix landmark orientation and reproducible measurement geometry. Using these guides, tooth height and width are annotated, and the region of interest is consistently defined at the central area of the middle third.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Accuracy of computer software, digital Spectrophotometer and visual method in shade matching using resin composite tabs.
기간: Baseline
• The outcome evaluates agreement of the computer software in comparison to spectrophotometer and traditional visual method.
Baseline

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 5월 1일

기본 완료 (추정된)

2026년 9월 1일

연구 완료 (추정된)

2026년 10월 1일

연구 등록 날짜

최초 제출

2026년 7월 10일

QC 기준을 충족하는 최초 제출

2026년 7월 15일

처음 게시됨 (실제)

2026년 7월 16일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 7월 16일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 7월 15일

마지막으로 확인됨

2026년 7월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 2026/0037

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

예

IPD 계획 설명

will be shared with supervisors

IPD 공유 지원 정보 유형

  • 연구_프로토콜
  • 수액
  • ICF
  • ANALYTIC_CODE
  • CSR

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .