Single-center Transformational Study on Feasibility and Efficacy of Respiratory Motion Management Using Novel Position Fixation Device for Lung Cancer Patients Undergoing Stereotactic Body Radiation Therapy(2023 No.358 Project)
This single-center study evaluates a novel body position and breath-holding device for lung cancer patients receiving stereotactic body radiation therapy. We will enroll 50 patients with single peripheral non-small cell lung cancer, compare tumor movement and radiation dose distribution with and without the device, to test if the device is safe, feasible and can improve treatment accuracy.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
For patients with peripheral non-small cell lung cancer receiving stereotactic body radiation therapy, respiratory motion often causes target volume deviation and compromises dose accuracy to tumors and nearby organs at risk. Current standard immobilization methods have limited ability to stabilize deep breathing patterns. This single-center translational study uses an integrated body position and breath-holding device, enrolling 50 eligible patients who will undergo 4DCT scans both with and without the device while keeping their clinical SBRT treatment plan unchanged. We will compare tumor motion amplitude, target coverage, conformity index and organ dose parameters between the two scanning states, to verify the device's feasibility, safety and value in improving treatment precision, providing clinical evidence for wider application in lung SBRT.
연구 유형
연구 유형
등록 (추정된)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Tianjin, 중국, 300000
- Tianjin Medical University Cancer Institute and Hospital
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Voluntarily participate and sign written informed consent
- Age ≥18 years, gender unlimited
- Clinically diagnosed with single peripheral lung cancer, assessed as suitable for SBRT
- Males or females of childbearing age willing to take contraceptive measures during the trial
- Female of childbearing age must have a negative pregnancy test within 7 days before treatment, and all patients use adequate contraception during treatment and for 4 weeks after
Exclusion Criteria:
- Intolerant or unwilling to receive the integrated respiratory suppression and positioning immobilization device for radiotherapy localization.
- Currently participating or planning to participate in other clinical trials.
- Refuse or be unable to sign the informed consent form for this trial.
- Patients with central or ultra-central lung cancer.
- Patients planned to receive SBRT for multiple pulmonary lesions.
- Patients assessed by the investigators of this trial as unsuitable for SBRT treatment.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: Single Arm - Novel Respiratory Immobilization
All enrolled patients receive 4DCT with and without the device |
A novel immobilization device used for respiratory motion management during lung stereotactic body radiation therapy |
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Mean respiratory motion amplitude of GTV and organs at risk (OARs) measured on 4DCT before and after abdominal pressure immobilization
기간: through study completion, an average of 1 year
|
Respiratory motion amplitude (maximum displacement) of gross tumor volume (GTV) and organs at risk (OARs) will be contoured and extracted from pre-abdominal-pressure 4DCT and post-abdominal-pressure 4DCT. The difference in motion amplitude between the two states will be compared to evaluate the feasibility and effectiveness of the novel abdominal pressure positioning membrane for lung SBRT. |
through study completion, an average of 1 year
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Conformity index (CI) of SBRT planning target volume (PTV)
기간: At the time of SBRT plan design, prior to treatment delivery
|
CI of PTV calculated from SBRT dose distribution after abdominal pressure immobilization |
At the time of SBRT plan design, prior to treatment delivery
|
|
Coverage of planning target volume (PTV)
기간: At the time of SBRT plan design, prior to treatment delivery
|
PTV coverage calculated from SBRT dose distribution after abdominal pressure immobilization |
At the time of SBRT plan design, prior to treatment delivery
|
|
Maximum relative dose at 2 cm outside the PTV boundary (D2cm)
기간: At the time of SBRT plan design, prior to treatment delivery
|
Percentage of maximum dose at the region 2 cm outside PTV boundary on SBRT plan |
At the time of SBRT plan design, prior to treatment delivery
|
|
Volume of normal ipsilateral lung receiving ≥20Gy,15Gy,10Gy and 5Gy (V20,V15, V10, V5)
기간: At the time of SBRT plan design, prior to treatment delivery
|
Dose-volume histogram parameters of normal treated lung from abdominal-pressure SBRT plan |
At the time of SBRT plan design, prior to treatment delivery
|
|
Maximum dose (Dmax) to organs at risk including spinal cord, heart and esophagus
기간: At the time of SBRT plan design, prior to treatment delivery
|
Dmax of OARs derived from SBRT dose plan under abdominal pressure immobilization |
At the time of SBRT plan design, prior to treatment delivery
|
공동 작업자 및 조사자
스폰서
스폰서
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (추정된)
기본 완료
연구 완료 (추정된)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
기타 연구 ID 번호
- bc20261997
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
This is an exploratory feasibility study, and no public sharing of individual patient data is planned.
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .