A Feasibility Study of a Wearable Arrhythmia Monitoring System (PulseON) in Stroke Patients (Crypto PulseON)
To evaluate the usability of the Pulse ON wearable device in patients with cryptogenic stroke/TIA
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
The research project aims to evaluate the usability of a new device for detecting heart rhythm disturbances, especially atrial fibrillation (AF) in people who have had a stroke or mini-stroke (transient ischaemic attack [TIA]) of unknown cause (cryptogenic stroke). AF can be a major cause of disabling strokes and AF-related stroke risk is significantly reduced by starting specific blood thinners called anticoagulants.
Stroke is a major public health concern worldwide, with approximately 100,000 cases annually in the UK alone, making it a leading cause of death and disability. Around 38,000 stroke-related deaths occur each year, and many survivors experience significant long-term impairment. The vast majority (~90%) are ischaemic strokes, yet in 20-40% of cases, no definitive underlying cause is identified, despite extensive evaluation. These cryptogenic stroke cases remain a diagnostic challenge. Cryptogenic strokes are more common in younger stroke patients (<60 years) but can affect all age groups.
AF is the most common arrhythmia and a well-established cause of ischaemic stroke, responsible for 15-30% of cases. However, in cryptogenic stroke, AF often goes undiagnosed because it can come and go (i.e. is paroxysmal) and can be asymptomatic in nature, with episodes that can last for short periods of time but carry high risk of stroke. Early and accurate diagnosis of AF is crucial, as clinical trials have demonstrated the efficacy of oral anticoagulation in significantly reducing stroke risk. Thus, identifying AF in cryptogenic stroke patients can directly impact management by shifting treatment towards anticoagulation.
Background. Detecting AF in cryptogenic stroke is a major challenge and many methods fail to capture episodes of AF that come and go (paroxysmal). Conventional AF detection methods, such as in-hospital cardiac monitoring, serial ECGs, Holter monitors, external event recorders, wearable devices and implantable loop recorders (ILRs), vary in effectiveness. ILRs are small devices (the size of a pen-lid) implanted under the skin of the left chest wall and have a battery life of around three years. They have demonstrated superior diagnostic sensitivity, as highlighted in the CRYSTAL-AF trial, which showed their advantage over standard monitoring in cryptogenic stroke (AF detection rate of 12.4% for ILRs vs 2% for standard monitoring at 12 months). However, ILRs are invasive (which comes with its own procedure-related risks), costly, and may not be suitable for all patients.2 We want to evaluate a different type of AF detection device (the PulseON Arrhythmia Monitor System) that is not currently used in standard care, one that's wrist worn and non-invasive.
Proposed trial We propose a single centre, single arm feasibility pilot study designed to evaluate how practical and user friendly it is for participants to use the PulseON Arrhythmia Monitor System for detecting AF in addition to their normal standard of care. The study will explore whether participants can wear the device as intended, respond to alerts and successfully carry out ECG recordings using the system, whilst capturing their user experience and having their heart tracings closely monitored by health care professionals.
Trial population At UHCW NHS Trust, we manage approximately 1,400 strokes annually (with 350 classified as cryptogenic), many of whom will need to be monitored for AF. While most patients undergo Holter monitoring for AF, a smaller subset receive ILRs but their use is limited due their cost and invasive nature. The introduction of this PulseON device could significantly enhance AF detection, improving patient outcomes, be more cost-effective and optimise resource utilisation within our hospital and the broader NHS. We plan to evaluate whether cardiac monitoring with the PulseON system is feasible in patients with cryptogenic stroke/TIA. This evaluation project may inform wider research into this device and potential NHS implementation.
Treatment / Intervention We aim to recruit twelve patients who have experienced a cryptogenic ischaemic stroke or TIA within the past six months for this project. All patients who participate in the project will receive conventional standard of care investigations (Holter monitoring or ILR) in addition to the PulseON Arrhythmia monitoring system. The data collected will include experience of device usability via an MS forms questionnaire and a follow-up patient interview, baseline demographics, usability data and any newly detected arrhythmia observed from the heart tracing data, in particular AF (defined as an episode of AF lasting >30seconds). Any arrhythmia documented from the PulseON device will be uploaded and stored in an encrypted and secure cloud-based server.
Participants heart tracing data will be collected and reviewed by a suitably qualified healthcare professional within the study team (primarily the Principal Investigator).The reviewer will assess any detected cardiac events to determine their clinical significance and, when appropriate, will escalate relevant findings to the participant's clinical care team. This process ensures that any new or emerging information arising from the study is used to support and inform the provision of standard clinical care for participants.
연구 유형
연구 유형
등록 (추정된)
등록
연락처 및 위치
연구 연락처
연구 연락처
- 이름: Andrew White
- 전화번호: 02476968582
- 이메일: andrew.white@uhcw.nhs.uk
연구 장소
-
-
-
Coventry, 영국, CV2 2DX
- 모병
- University Hospital Coventry & Warwickshire NHS Trust
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
Patients diagnosed with cryptogenic stroke/TIA
설명
Inclusion Criteria:
- Adult patients (>18yrs old) diagnosed with cryptogenic stroke / TIA
- Baseline electrocardiogram (ECG), Holter monitor and echocardiogram as part of the standard of care cardiac work-up in the diagnosis of cryptogenic stroke
Exclusion Criteria:
- Patients unwilling or unable to wear the PulseON arrhythmia detection device.
- Known pre-existing AF or atrial arrhythmia diagnosis.
- Participants without capacity will be excluded from this study.
- Participants who are pregnant will be excluded from this study.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: COHORT
- 시간 관점: PROSPECTIVE
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Usability & Feasibility of PulseON wearable device
기간: 1 month minimum
|
We will collect patient questionnaires and perform patient interviews to gather data on the PulseON device for usability and feasibility data. Formal feedback from health professionals who follow up the trial participants via the PulseON arrhythmia monitoring system online will be obtained. |
1 month minimum
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
The prevalence of AF in people who have had cryptogenic ischaemic stroke or TIA.
기간: 1 month
|
The ability of Pulse ON in detecting AF on ECG and how it differs from the standard of care (ECG, Holter monitoring or ILR) |
1 month
|
|
Baseline characteristics of cohort
기간: 1 month
|
Baseline demographic and clinical characteristics |
1 month
|
공동 작업자 및 조사자
스폰서
스폰서
수사관
수사관
- 연구 책임자: Faizel Osman, University Hospital Coventry & Warwickshire
- 수석 연구원: Ven G Lim, University Hospital Coventry & Warwickshire
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (추정된)
기본 완료
연구 완료 (추정된)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
기타 연구 ID 번호
- FO658425
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .