이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

IRB-HSR# 14299: The Use of the Intrathoracic Pressure Regulator (ITPR) to Improve Cerebral Perfusion Pressure in Patients With Altered Intracranial Elastance

2010년 9월 17일 업데이트: University of Virginia

Patients who have a functioning intracranial pressure-monitoring device (either a subarachnoid bolt, or an intraventricular catheter) in place, and are either sedated, intubated, and mechanically ventilated (i.e. in the NNICU), or are scheduled to undergo an operation or interventional neuroradiological procedure at the University of Virginia. Patients with a contraindication to TTE will be excluded.

For patients in the NNICU, basic hemodynamic variables (systemic blood pressure, central venous pressure, etc.) will be collected. In addition, left ventricular performance (including estimates of LVEDV, LVESV, EF, FAC, and SV) will be assessed using TTE. Once these baseline data are recorded, the ITPR will be inserted in the ventilator circuit and activated to provide either -5 mm Hg or -9 mm Hg endotracheal rube pressure (ETP) (based on a randomization scheme). After the ITPR has been active for at least five minutes, the same intracranial, hemodynamic, and TTE data obtained above will be gathered. The ITPR will then be turned off for five minutes, and intracranial, hemodynamic, and TTE data will again be recorded. The ITPR will be activated a second time (-9 mm Hg or -5 mm Hg ETP, i.e. whichever value was not used previously), and after five minutes of use data will be recorded again. The ITPR will then be disconnected, data will be collected after waiting two minutes, and no further interventions will be made.

ABG's will be obtained before and during the use of the device at each setting.

This is a proof of concept/feasibility study designed to test the primary hypothesis that use of the ITPR will result in decreased intracranial pressure and increased cerebral perfusion pressure. The effect of the ITPR on secondary indicators of cardiac performance will also be examined. These include but are not limited estimates of ventricular end diastolic volume and pressure (LVEDV/P), ejection fraction (EF), left ventricular end systolic volume and pressure (LVESV/P), fractional area change (FAC), all of which will be assessed by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE).

연구 개요

상세 설명

The ITPR is an FDA-approved device intended to increase circulation and blood pressure in hypovolemic and cardiogenic shock. The device is inserted within a standard respiratory circuit between the patient and the ventilator. It functions by decreasing intrathoracic pressure during the expiratory phase to subatmospheric levels after each positive pressure ventilation. This decrease in intrathoracic pressure creates a vacuum within the thorax relative to the rest of the body, thereby enhancing venous return to the heart and consequently increasing cardiac output and blood pressure. Activation of the device is also accompanied by a decrease in SVR. The end result is a device that simultaneously improves cardiac output by increasing LVEDV and decreasing SVR while increasing coronary perfusion pressure by increasing blood pressure and decreasing LVESP/LVESV.1-8

Interestingly, while the ITPR was developed as a non-invasive mechanism to increase preload in hypovolemic patients, its mechanism of action (generation of subatmospheric intrathoracic pressure) has been shown to reduce intracranial pressure6. This is critical in brain-injured patients, because elevated intracranial pressure is strongly associated with poor outcome in traumatic brain injury (TBI) patients - in a recent study of 846 TBI patients, those with ICP < 20 mm Hg by 48 hours had a mortality rate of 14%, whereas those with ICP > 20 mm Hg had a mortality rate of 34%9. Particularly interesting are the ITPR's combined benefits of increased MAP and decreased ICP, as hypotension is a well-known poor prognostic indicator in this patient population.

In fact, according to the Brain Trauma Foundation Guidelines, "Hypotension, occurring at any time from injury through the acute intensive care course, has been found to be a primary predictor of outcome from severe head injury for the health care delivery systems within which prognostic variables have been best studied. Hypotension is repeatedly found to be one of the five most powerful predictors of outcome and is generally the only one of these five that is amenable to therapeutic modification. A single recording of a hypotensive episode is generally associated with a doubling of mortality and a marked increase in morbidity from a given head injury10."

Importantly, cerebral perfusion pressure (mean arterial pressure - the greater of ICP or CVP) is only a surrogate marker for cerebral blood flow. The function of hypotension as a useful clinical variable is dependent on two factors - first, its correlation with the true variable of interest (cerebral blood flow) and second, the ability of clinicians to manipulate the underlying variable of interest (cerebral blood flow) based on the surrogate marker (cerebral perfusion pressure).

The acceptable level of hypotension in patients with brain injuries has not been determined, and the Brain Trauma Foundation (BTF) Guidelines recommend maintaining systolic blood pressures > 90 mm Hg, but acknowledge that this number is relatively arbitrary and not based on any high-level studies (thus assigning it a designation of Level II evidence) 11. The BTF Guidelines further state that because hypotension is such a poor prognostic variable, it would be unethical to randomize patients to various blood pressure goals, and therefore Level I evidence is not forthcoming. Further complicating the situation is the lack of agreement on how to increase blood pressure (with the hopes of increasing cerebral perfusion pressure)12-15. Many of the pharmacologic agents used to increase mean arterial pressure have significant vasoconstrictive effects, which could counteract any increase blood pressure and lead to unchanged, or even reduced cerebral blood flow.

연구 유형

중재적

등록 (예상)

20

단계

  • 2 단계

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Virginia
      • Charlottesville, Virginia, 미국, 22908
        • University of Virginia Health System

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • 1. patients who have a functioning intracranial pressure-monitoring device (either a subarachnoid bolt, or an intraventricular catheter) in place, and are either sedated, intubated, and mechanically ventilated (i.e. in the NNICU)and have an arterial line in place, or are scheduled to undergo an operation or interventional neuroradiological procedure at the University of Virginia.

    2. age 18 years of age and older 3. informed consent/ surrogate consent has been obtained

Exclusion Criteria:

  • 1. pneumothorax 2. hemothroax 3. uncontrolled bleeding 4. uncontrolled hypertension defined as SBP > 180 mmHg at the time of surgery 5. known respiratory disease such as chronic emphysema, COPD, or Cystic Fibrosis

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 건강 서비스 연구
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 더블

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: ITPR -9 & then -5 mm Hg
the ITPR will be inserted in the ventilator circuit and activated to provide either -5 mm Hg or -9 mm Hg endotracheal tube pressure (ETP) Each subject will have all measurements recorded at both -5 & -9 mm Hg
the ITPR will be inserted in the ventilator circuit and activated to provide either -5 mm Hg or -9 mm Hg endotracheal tube pressure (ETP) Each subject will have all measurements recorded at both -5 & -9 mm Hg
실험적: ITPR -5 & then _9 mm HG
the ITPR will be inserted in the ventilator circuit and activated to provide either -5 mm Hg or -9 mm Hg endotracheal tube pressure (ETP) Each subject will have all measurements recorded at both -5 & -9 mm Hg
the ITPR will be inserted in the ventilator circuit and activated to provide either -5 mm Hg or -9 mm Hg endotracheal tube pressure (ETP) Each subject will have all measurements recorded at both -5 & -9 mm Hg

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Hemodynamic variables
기간: baseline, 5 minutes after device activation & 5 minutes after device turned off
hemodynamic variables (systemic blood pressure, central venous pressure, ICP) will be collected at baseline, 5 minutes after device activation & 5 minutes after device turned off
baseline, 5 minutes after device activation & 5 minutes after device turned off

2차 결과 측정

결과 측정
측정값 설명
기간
cardiac performance
기간: baseline, 5 minutes after device activation & 5 minutes after device turned off
cardiac performance will also be examined. These include but are not limited estimates of ventricular end diastolic volume and pressure (LVEDV/P), ejection fraction (EF), left ventricular end systolic volume and pressure (LVESV/P), fractional area change (FAC)
baseline, 5 minutes after device activation & 5 minutes after device turned off

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Edward C Nemergfut, MD, University of Virginia Anesthesiology

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2009년 5월 1일

연구 등록 날짜

최초 제출

2010년 9월 17일

QC 기준을 충족하는 최초 제출

2010년 9월 17일

처음 게시됨 (추정)

2010년 9월 20일

연구 기록 업데이트

마지막 업데이트 게시됨 (추정)

2010년 9월 20일

QC 기준을 충족하는 마지막 업데이트 제출

2010년 9월 17일

마지막으로 확인됨

2010년 9월 1일

추가 정보

이 연구와 관련된 용어

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

외상성 뇌 손상에 대한 임상 시험

3
구독하다