Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Two Dimensional (2D) Silicon Transducer-Compression Plates for Breast Ultrasound

3 mei 2016 bijgewerkt door: Paul L. Carson Ph.D, University of Michigan

2D Silicon Transducer-Compression Plates for Breast Ultrasound

The study purpose is to help in the developement of 3 dimensional breast ultrasound imaging.

Studie Overzicht

Gedetailleerde beschrijving

To assist in the developement of 3 dimensional breast ultrasound imaging and when possible compare the ultrasound results with 3D mammography (digital tomosynthesis mammography)or clinical mammography and ultrasound. Hopefully that this new, 3D ultrasound imaging can provide important information not found on mammograms or routine breast ultrasound.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

21

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Michigan
      • Ann Arbor, Michigan, Verenigde Staten, 48109
        • University of Michigan

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

30 jaar tot 80 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Ja

Geslachten die in aanmerking komen voor studie

Vrouw

Beschrijving

Inclusion Criteria:

  • Healthy women OR
  • Women with suspected benign masses who may/or may not be going to biopsy
  • Women with cysts where no biopsy is recommended

Exclusion Criteria:

  • Women who are pregnant
  • Women with breast implants
  • Prisoners

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Breast imaging using Ultrasound and Photoacoustic
Evaluating 3D ultrasound for breast abnormalities/masses/cysts. This includes ultrasound imaging and possibly photoacoustic imaging.
Subjects will be seated and have the indicated breast positioned in the 3D breast ultrasound imaging device. An ultrasound gel will be applied to the breast by the technician. The breast will be gently compressed between the ultrasound plates to facilitate the 3D (dimensional)breast imaging. This imaging session will take approximately 30 minutes to complete.
Subjects will be placed in a seated position for the photoacoustic tomography(PAT) imaging. The subjects will be given a laser protective mask to wear. Each subject will be instructed how to wear this mask(goggles) to protect their eyes during the imaging session. Pulse monitor leads may be placed on their chest to allow the computer to record the images of blood flow in the breast. The breast will be placed on the laser device platform and positioned so that the laser beam is appropriately directed to the targeted area of the breast. During the imaging the temperature of the skin under laser light, will be checked often with a thermometer to make sure that the skin is not getting too hot. This laser based imaging scan will take approximately 10 minutes to complete.
Andere namen:
  • Photoacoustic Tomography (PAT)

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
To prove the significance/capability of 3D Ultrasound imaging in comparison to current mammographic imaging.
Tijdsspanne: 1 year
Assess the quality of 3 D ultrasound in comparison to conventional mammography
1 year

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Paul Carson, Ph.D., University of Michigan Basic Science Division

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 maart 2009

Primaire voltooiing (Werkelijk)

1 februari 2015

Studie voltooiing (Werkelijk)

1 februari 2015

Studieregistratiedata

Eerst ingediend

9 maart 2009

Eerst ingediend dat voldeed aan de QC-criteria

9 maart 2009

Eerst geplaatst (Schatting)

11 maart 2009

Updates van studierecords

Laatste update geplaatst (Schatting)

5 mei 2016

Laatste update ingediend die voldeed aan QC-criteria

3 mei 2016

Laatst geverifieerd

1 mei 2016

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • HUM 15464
  • 2R01CA091713 (Subsidie/contract van de Amerikaanse NIH)
  • R01CA115267 (Subsidie/contract van de Amerikaanse NIH)

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .