- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01727661
Cardiopulmonary Fitness, Lung Function, Muscular Oxygen Saturation, and Quality of Life in T1DM
Cardiopulmonary Fitness, Lung Function, Muscular Oxygen Saturation, and Quality of Life in Patients With Type 1 Diabetes Mellitus
The purpose of this study is to compare the differences of
- cardiopulmonary fitness
- lung function
- muscular oxygen saturation
- quality of life between type 1 diabetes mellitus and healthy adults.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Taipei, Taiwan, 100
- National Taiwan University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- diagnosis of type 1 diabetes mellitus ≥2 years (diabetic group)
- age-, gender-, and BMI-matched healthy subjects (control group)
Exclusion Criteria:
- cardiac or respiratory disease
- pregnancy
- hospitalization due to any medical condition in recent 6 months
- any other condition affecting exercise performance or lung function.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
type 1 diabetes mellitus
|
subjects will sit on the ergometer, resting heart rate and BP will be measured for at least 2 minutes.
Before testing, each participant will be informed to perform cycling with 0 watt for 2 minutes.
Then, exercise testing will be started at 30 watt, and increase 15 watt in male and 10 watt in female every minute until the termination criteria achieved.
spirometry testing: Each participant will then place mouthpiece in mouth and close lips around the mouthpiece. Participants will inhale completely and rapidly and then exhale maximally until no more air could be expelled while maintaining an upright position. Values of FEV1 (forced expiratory volume in 1 second) and FVC (forced vital capacity) will be calculated immediately after the exhalation. single-breath carbon monoxide diffusing capacity: Participants will sit on a firm and nose clips will then be attached and mouthpiece be placed in mouth. After participants perform several stable breathes, testing starts with a complete exhalation. Each participant will be instructed to inhale rapidly and completely and then hold for 10 seconds.
assessing quality of life using short-forum 36 (questionnaire)
|
|
healthy controls
|
subjects will sit on the ergometer, resting heart rate and BP will be measured for at least 2 minutes.
Before testing, each participant will be informed to perform cycling with 0 watt for 2 minutes.
Then, exercise testing will be started at 30 watt, and increase 15 watt in male and 10 watt in female every minute until the termination criteria achieved.
spirometry testing: Each participant will then place mouthpiece in mouth and close lips around the mouthpiece. Participants will inhale completely and rapidly and then exhale maximally until no more air could be expelled while maintaining an upright position. Values of FEV1 (forced expiratory volume in 1 second) and FVC (forced vital capacity) will be calculated immediately after the exhalation. single-breath carbon monoxide diffusing capacity: Participants will sit on a firm and nose clips will then be attached and mouthpiece be placed in mouth. After participants perform several stable breathes, testing starts with a complete exhalation. Each participant will be instructed to inhale rapidly and completely and then hold for 10 seconds.
assessing quality of life using short-forum 36 (questionnaire)
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
exercise testing with near-infrared spectroscopy
Tijdsspanne: at baseline
|
at baseline
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
lung function
Tijdsspanne: at baseline
|
flow volume loop, lung diffusing capacity
|
at baseline
|
|
quality of life
Tijdsspanne: at baseline
|
short-forum 36
|
at baseline
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Ying-Tai Wu, phD, National Taiwan University Hospital
Publicaties en nuttige links
Algemene publicaties
- Wanke T, Formanek D, Auinger M, Zwick H, Irsigler K. Pulmonary gas exchange and oxygen uptake during exercise in patients with type 1 diabetes mellitus. Diabet Med. 1992 Apr;9(3):252-7. doi: 10.1111/j.1464-5491.1992.tb01771.x.
- Komatsu WR, Barros Neto TL, Chacra AR, Dib SA. Aerobic exercise capacity and pulmonary function in athletes with and without type 1 diabetes. Diabetes Care. 2010 Dec;33(12):2555-7. doi: 10.2337/dc10-0769. Epub 2010 Aug 31.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 201201005RIC
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .