- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01727661
Cardiopulmonary Fitness, Lung Function, Muscular Oxygen Saturation, and Quality of Life in T1DM
Cardiopulmonary Fitness, Lung Function, Muscular Oxygen Saturation, and Quality of Life in Patients With Type 1 Diabetes Mellitus
The purpose of this study is to compare the differences of
- cardiopulmonary fitness
- lung function
- muscular oxygen saturation
- quality of life between type 1 diabetes mellitus and healthy adults.
Descripción general del estudio
Estado
Condiciones
Descripción detallada
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Taipei, Taiwán, 100
- National Taiwan University Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- diagnosis of type 1 diabetes mellitus ≥2 years (diabetic group)
- age-, gender-, and BMI-matched healthy subjects (control group)
Exclusion Criteria:
- cardiac or respiratory disease
- pregnancy
- hospitalization due to any medical condition in recent 6 months
- any other condition affecting exercise performance or lung function.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
type 1 diabetes mellitus
|
subjects will sit on the ergometer, resting heart rate and BP will be measured for at least 2 minutes.
Before testing, each participant will be informed to perform cycling with 0 watt for 2 minutes.
Then, exercise testing will be started at 30 watt, and increase 15 watt in male and 10 watt in female every minute until the termination criteria achieved.
spirometry testing: Each participant will then place mouthpiece in mouth and close lips around the mouthpiece. Participants will inhale completely and rapidly and then exhale maximally until no more air could be expelled while maintaining an upright position. Values of FEV1 (forced expiratory volume in 1 second) and FVC (forced vital capacity) will be calculated immediately after the exhalation. single-breath carbon monoxide diffusing capacity: Participants will sit on a firm and nose clips will then be attached and mouthpiece be placed in mouth. After participants perform several stable breathes, testing starts with a complete exhalation. Each participant will be instructed to inhale rapidly and completely and then hold for 10 seconds.
assessing quality of life using short-forum 36 (questionnaire)
|
|
healthy controls
|
subjects will sit on the ergometer, resting heart rate and BP will be measured for at least 2 minutes.
Before testing, each participant will be informed to perform cycling with 0 watt for 2 minutes.
Then, exercise testing will be started at 30 watt, and increase 15 watt in male and 10 watt in female every minute until the termination criteria achieved.
spirometry testing: Each participant will then place mouthpiece in mouth and close lips around the mouthpiece. Participants will inhale completely and rapidly and then exhale maximally until no more air could be expelled while maintaining an upright position. Values of FEV1 (forced expiratory volume in 1 second) and FVC (forced vital capacity) will be calculated immediately after the exhalation. single-breath carbon monoxide diffusing capacity: Participants will sit on a firm and nose clips will then be attached and mouthpiece be placed in mouth. After participants perform several stable breathes, testing starts with a complete exhalation. Each participant will be instructed to inhale rapidly and completely and then hold for 10 seconds.
assessing quality of life using short-forum 36 (questionnaire)
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
exercise testing with near-infrared spectroscopy
Periodo de tiempo: at baseline
|
at baseline
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
lung function
Periodo de tiempo: at baseline
|
flow volume loop, lung diffusing capacity
|
at baseline
|
|
quality of life
Periodo de tiempo: at baseline
|
short-forum 36
|
at baseline
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ying-Tai Wu, phD, National Taiwan University Hospital
Publicaciones y enlaces útiles
Publicaciones Generales
- Wanke T, Formanek D, Auinger M, Zwick H, Irsigler K. Pulmonary gas exchange and oxygen uptake during exercise in patients with type 1 diabetes mellitus. Diabet Med. 1992 Apr;9(3):252-7. doi: 10.1111/j.1464-5491.1992.tb01771.x.
- Komatsu WR, Barros Neto TL, Chacra AR, Dib SA. Aerobic exercise capacity and pulmonary function in athletes with and without type 1 diabetes. Diabetes Care. 2010 Dec;33(12):2555-7. doi: 10.2337/dc10-0769. Epub 2010 Aug 31.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 201201005RIC
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .