Endotracheal Tube Cuff Inflation Pressure Varieties and Response to Education Among Anesthetists

29 augustus 2021 bijgewerkt door: Abdelrhman Alshawadfy, Suez Canal University

Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients.

This study will investigate the endotracheal ETT cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply.

Studie Overzicht

Gedetailleerde beschrijving

Although the increasing uses of different supraglottic devices as an alternative, the traditional endotracheal intubation is still considered the commonly used method for managing the airway of a generally anaesthetized patient. After passing the endotracheal tube through the larynx, the anaesthetist inflates the cuff or asks the anaesthesia technician to inflate it. How much air is injected into the cuff is not a major concern for almost all anaesthetists and they usually depend on palpating the external cuff tense to judge is it too much, accurate or not enough? Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. Inflation of the cuff of pressure more than 30 cm H2O can damage the tracheal mucosa by compromising capillary perfusion. When pressures are greater than 50 cm H2O, total obstruction of tracheal blood flow occurs. For long times, without any evidence-based data, it has been believed that well-trained anaesthetists are capable of determining proper ETT cuff pressures. It is presumed that anaesthetists can detect appropriate inflation pressure and overinflated ETT cuff by palpating the ETT pilot balloon. Adequacy of cuff inflation is conventionally determined by palpation of the external balloon. Previous studies suggest that this approach is unreliable. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients. However, increased awareness of over-inflation risks may have improved recent clinical practice.

The aim of the work: This study will investigate the endotracheal cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply. Material and Methods: Type of the study: Prospective controlled single-blind study. Settings: After obtaining approval by the Ethics Committee of the Suez Canal University Hospital, and written informed consent with an explanation regarding the purpose, effects, technique, and complications, all anaesthetists, working currently in the facility, are included.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

28

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Ismailia, Egypte, 2685
        • Suez Canal University

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind
  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • anaesthetists
  • works at Suez canal university hospital
  • resident, registrar, or senior registrar

Exclusion Criteria:

  • refusal to participate
  • who will not complete the 2 rounds 3 readings each

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Preventie
  • Toewijzing: Niet-gerandomiseerd
  • Interventioneel model: Sequentiële toewijzing
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Before education

Before alarming the participant anaesthetists about the pressure values of their practice in inflating the ETT cuff.

This is before applying the intervention which is informing and educating the participant anaesthetists about the proper ETT cuff pressure.

Before applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.
Actieve vergelijker: After education

After alarming the participant anaesthetists about the pressure values of their practice in inflating the ETT cuff.

This is after applying the intervention which is informing and educating the participant anaesthetists about the proper ETT cuff pressure.

After applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
accuracy in inflating the cuff of the endotracheal tubes
Tijdsspanne: immediately after fixation of the endotracheal tube during general anaethesia
assessment of the Anesthetists' accuracy in inflating the cuff of the endotracheal tubes used to maintain the airway of generally anaesthetized patients the change following feedback.
immediately after fixation of the endotracheal tube during general anaethesia

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 januari 2018

Primaire voltooiing (Werkelijk)

1 februari 2018

Studie voltooiing (Werkelijk)

1 mei 2018

Studieregistratiedata

Eerst ingediend

25 augustus 2021

Eerst ingediend dat voldeed aan de QC-criteria

29 augustus 2021

Eerst geplaatst (Werkelijk)

5 september 2021

Updates van studierecords

Laatste update geplaatst (Werkelijk)

5 september 2021

Laatste update ingediend die voldeed aan QC-criteria

29 augustus 2021

Laatst geverifieerd

1 augustus 2021

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • ETT cuff pressure

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

ONBESLIST

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren