Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Endotracheal Tube Cuff Inflation Pressure Varieties and Response to Education Among Anesthetists

29. august 2021 opdateret af: Abdelrhman Alshawadfy, Suez Canal University

Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients.

This study will investigate the endotracheal ETT cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply.

Studieoversigt

Detaljeret beskrivelse

Although the increasing uses of different supraglottic devices as an alternative, the traditional endotracheal intubation is still considered the commonly used method for managing the airway of a generally anaesthetized patient. After passing the endotracheal tube through the larynx, the anaesthetist inflates the cuff or asks the anaesthesia technician to inflate it. How much air is injected into the cuff is not a major concern for almost all anaesthetists and they usually depend on palpating the external cuff tense to judge is it too much, accurate or not enough? Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. Inflation of the cuff of pressure more than 30 cm H2O can damage the tracheal mucosa by compromising capillary perfusion. When pressures are greater than 50 cm H2O, total obstruction of tracheal blood flow occurs. For long times, without any evidence-based data, it has been believed that well-trained anaesthetists are capable of determining proper ETT cuff pressures. It is presumed that anaesthetists can detect appropriate inflation pressure and overinflated ETT cuff by palpating the ETT pilot balloon. Adequacy of cuff inflation is conventionally determined by palpation of the external balloon. Previous studies suggest that this approach is unreliable. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients. However, increased awareness of over-inflation risks may have improved recent clinical practice.

The aim of the work: This study will investigate the endotracheal cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply. Material and Methods: Type of the study: Prospective controlled single-blind study. Settings: After obtaining approval by the Ethics Committee of the Suez Canal University Hospital, and written informed consent with an explanation regarding the purpose, effects, technique, and complications, all anaesthetists, working currently in the facility, are included.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

28

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Ismailia, Egypten, 2685
        • Suez Canal University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Barn
  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • anaesthetists
  • works at Suez canal university hospital
  • resident, registrar, or senior registrar

Exclusion Criteria:

  • refusal to participate
  • who will not complete the 2 rounds 3 readings each

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Forebyggelse
  • Tildeling: Ikke-randomiseret
  • Interventionel model: Sekventiel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Before education

Before alarming the participant anaesthetists about the pressure values of their practice in inflating the ETT cuff.

This is before applying the intervention which is informing and educating the participant anaesthetists about the proper ETT cuff pressure.

Before applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.
Aktiv komparator: After education

After alarming the participant anaesthetists about the pressure values of their practice in inflating the ETT cuff.

This is after applying the intervention which is informing and educating the participant anaesthetists about the proper ETT cuff pressure.

After applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
accuracy in inflating the cuff of the endotracheal tubes
Tidsramme: immediately after fixation of the endotracheal tube during general anaethesia
assessment of the Anesthetists' accuracy in inflating the cuff of the endotracheal tubes used to maintain the airway of generally anaesthetized patients the change following feedback.
immediately after fixation of the endotracheal tube during general anaethesia

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. januar 2018

Primær færdiggørelse (Faktiske)

1. februar 2018

Studieafslutning (Faktiske)

1. maj 2018

Datoer for studieregistrering

Først indsendt

25. august 2021

Først indsendt, der opfyldte QC-kriterier

29. august 2021

Først opslået (Faktiske)

5. september 2021

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

5. september 2021

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

29. august 2021

Sidst verificeret

1. august 2021

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • ETT cuff pressure

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

UBESLUTET

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Endotracheal Tube

Kliniske forsøg med Before the education program

3
Abonner