Safety and Efficacy Study of MGuard Stent After a Heart Attack (MASTER)
28. mai 2013 oppdatert av: InspireMD
MASTER: MGUARD for Acute ST Elevation Reperfusion
The goal of this study is to demonstrate the superiority of the MGuard™ stent over commercially-approved bare-metal (BMS) /drug-eluting stents (DES) in achieving better myocardial reperfusion in primary angioplasty for the treatment of acute ST-elevation myocardial infarction (STEMI).
Studieoversikt
Status
Fullført
Forhold
Intervensjon / Behandling
Studietype
Intervensjonell
Registrering (Faktiske)
433
Fase
- Fase 4
Kontakter og plasseringer
Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.
Studiesteder
-
-
-
Białystok, Polen
- Klinika Kardiologii Inwazyjnej Uniwersytetu Medycznego w Białymstoku
-
Krakow, Polen
- Gilghsin: John Paul II Hospital
-
Krakow, Polen
- Szpital Uniwersytecki w Krakowie
-
Nowy Targ, Polen
- Oddział Kardiologii Inwazyjnej
-
Oświęcim, Polen
- Centrum Kardiologii Inwazyjnej GVM Carint
-
Warsaw, Polen
- Centralny Szpital Kliniczny MSWiA w Warszawie
-
-
-
-
-
Johannesburg, Sør-Afrika
- Milpark Hospital
-
-
Deltakelseskriterier
Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
18 år og eldre (Voksen, Eldre voksen)
Tar imot friske frivillige
Nei
Kjønn som er kvalifisert for studier
Alle
Beskrivelse
Inclusion Criteria
- 18 years of age
- ST-segment elevation (more than 2mm in more than contiguous leads)
- MI with symptom onset less than 12h
- The patient is willing to comply with specified follow-up evaluations
- Signed ICF
- Single de novo lesion in the target (culprit) vessel
- Target lesion maximum length is 33 mm (by visual estimation)
- Reference vessel diameter must be more than 3.0 to less than 4.0 mm by visual estimation
- Randomization should occur as soon as Presence of TIMI 2 or 3 before randomization Exclusion Criteria
- Pregnant or nursing patients
- Left Bundle Branch Block (LBBB), paced rhythm, or other Electrocardiogram (ECG) abnormality
- Impaired renal function
- Prior coronary artery bypass graft surgery
- Bleeding diathesis
- Contraindication to aspirin
- cardiopulmonary resuscitation
- Cardiogenic shock
- chronic warfarin anticoagulation
- LVEF less than 20%
- other medical illness
- participation in another investigational drug or device study that has not reached its primary endpoint
- Left main coronary artery disease with 50% stenosis
- Ostial target lesion
- Failure to visualize vessel anatomy distal to the culprit lesion
- Moderate to heavily calcified target lesion or vessel
- excessive tortuosity
- bifurcation with a side branch more than 2.0 mm in diameter
- A significant (greater than 50%) stenosis proximal or distal to the target lesion is present that cannot be covered by same single stent
- Diffuse disease distal to target lesion with impaired runoff
- Any prior stent proximal to the target lesion, or within 10 mm distal of the target lesion
- PCI of another lesion performed within 6 months before the index procedure
- Target lesion located in a saphenous vein graft
Studieplan
Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: MGuard
MGuard stent will be deployed
|
MGuard™ stent comprises a balloon-expandable, thin-strut stainless steel (316L) bare metal stent platform (strut width 100 µm) with mesh sleeve fibers of polyethyleneterephtalate (fiber width of 20 µm) attached to its outer surface.
These fibers act like a net (aperture size 150 x 180 µm) preventing distal embolization of the plaque debris/thrombus placed between the vessel wall and the stent.
|
|
Aktiv komparator: BMS or DES
A regular bare metal stent or drug-eluting stent will be deployed
|
Control BMS or DES
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
The incidence of complete ST segment resolution (defined as ≥70% ST 1. The incidence of complete ST segment resolution
Tidsramme: 60 to 90 minutes after the last angiogram
|
60 to 90 minutes after the last angiogram
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
The incidence of Thrombolysis In Myocardial Infarction (TIMI) 3 flow at the end of the procedure.
Tidsramme: 60-90 minutes after last angiogram
|
The incidence of TIMI 3 flow at the end of the procedure.
|
60-90 minutes after last angiogram
|
|
Major Adverse Cardiac Events (MACE)at discharge, 30 days, 6 months and 12 months post-procedure
Tidsramme: discharge, 30 days, 6 and 12 months post-procedure
|
Major Adverse Cardiac Events (MACE): defined as cardiac death, reinfarction (Q wave and non-Q wave), or repeat ischemia-driven target lesion revascularization (TLR) by percutaneous or surgical methods at hospital discharge, 30 days, 6 months and 1 year post-procedure.
|
discharge, 30 days, 6 and 12 months post-procedure
|
Samarbeidspartnere og etterforskere
Det er her du vil finne personer og organisasjoner som er involvert i denne studien.
Sponsor
Etterforskere
- Hovedetterforsker: Alexandre Abizaid, MD, PhD, Inst Dante Pazzanese of Cardiology, Brazil
- Hovedetterforsker: Dariusz Dudek, MD, PhD, Cardiac Catheterization Laboratories, Krakow, Poland
- Hovedetterforsker: Sigmund Silber, MD, PhD, Heart Center at the Isar Academic Teaching Site of the University of Munich
- Studiestol: Gregg Stone, MD, Columbia University Medical Center The Cardiovascular Research Foundation
Publikasjoner og nyttige lenker
Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.
Generelle publikasjoner
- Dudek D, Dziewierz A, Brener SJ, Abizaid A, Merkely B, Costa RA, Bar E, Rakowski T, Kornowski R, Dressler O, Abizaid A, Silber S, Stone GW. Mesh-covered embolic protection stent implantation in ST-segment-elevation myocardial infarction: final 1-year clinical and angiographic results from the MGUARD for acute ST elevation reperfusion trial. Circ Cardiovasc Interv. 2015 Feb;8(2):e001484. doi: 10.1161/CIRCINTERVENTIONS.114.001484.
- Dudek D, Brener SJ, Rakowski T, Dziewierz A, Abizaid A, Silber S, Yaacoby E, Dizon JM, Costa RA, Maehara A, Dressler O, Stone GW. Efficacy of an Embolic Protection Stent as a Function of Delay to Reperfusion in ST-Segment Elevation Myocardial Infarction (from the MASTER Trial). Am J Cardiol. 2014 Nov 15;114(10):1485-9. doi: 10.1016/j.amjcard.2014.08.007. Epub 2014 Aug 27.
- Stone GW, Abizaid A, Silber S, Dizon JM, Merkely B, Costa RA, Kornowski R, Abizaid A, Wojdyla R, Maehara A, Dressler O, Brener SJ, Bar E, Dudek D. Prospective, Randomized, Multicenter Evaluation of a Polyethylene Terephthalate Micronet Mesh-Covered Stent (MGuard) in ST-Segment Elevation Myocardial Infarction: The MASTER Trial. J Am Coll Cardiol. 2012 Nov 6;60(19):1975-84. doi: 10.1016/j.jacc.2012.09.004.
Studierekorddatoer
Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.
Studer hoveddatoer
Studiestart
1. juni 2011
Primær fullføring (Faktiske)
1. juni 2012
Studiet fullført (Faktiske)
1. juni 2012
Datoer for studieregistrering
Først innsendt
17. februar 2011
Først innsendt som oppfylte QC-kriteriene
7. juni 2011
Først lagt ut (Anslag)
8. juni 2011
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
29. mai 2013
Siste oppdatering sendt inn som oppfylte QC-kriteriene
28. mai 2013
Sist bekreftet
1. mai 2013
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- IMD-07
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Nei
Studerer et amerikansk FDA-regulert enhetsprodukt
Nei
produkt produsert i og eksportert fra USA
Nei
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .