Carbon PEEK Versus Titanium Pedicle-skruer ved behandling av spinale svulster
Carbon PEEK versus titan pedicle skruer i behandling av spinal tumorer - en randomisert kontrollert prøvelse
Radiation therapy is a cornerstone in the treatment of spinal neoplasms as radical resections are often limited anatomically. Frequently, a surgical stabilization with implants is required. However, metallic implants not only make the CT-based planning of a subsequent radiation therapy more difficult, but might also have an uncontrolled dose modulating effect in adjuvant radiotherapy. At the spine, radiation is limited by the effective dose posed to the relatively radiosensitive spinal cord. While metallic implants might result in an inhomogeneous and uncontrollable dose distribution due to the interface effect, the use of new radiolucent implants consisting of carbon/polyether ether ketone (PEEK) might allow a more homogeneous and predictable dose distribution. This study aims to evaluate the potential benefits of the use of carbon/PEEK pedicle screws during adjuvant radiation therapy and follow-up imaging of spinal tumors.
60 patients will randomized 1:1 into either treatment arm (Pedicle System Carbon/PEEK vs. Pedicle System Titanium). The feasibility of planning the radiation therapy will be evaluated. The postoperatively administered total radiation dose is documented. The radiological visualization of the area of interest will be evaluated The surgical outcome is evaluated by fusion rate, implant integrity and anchorage. Patients will be followed up for 12 months according to local standards.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Canton of Zurich
-
Zurich, Canton of Zurich, Sveits, 8008
- University Hospital Balgrist
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Patients 18 to 99 years of Age
- Primary and secondary spinal tumors of the thoracolumbar spine requiring posterior instrumentation and radiation therapy
Exclusion Criteria:
- Need of cement augmentation or anterior cage support (corpectomy)
- Patients with contraindication against surgical resection
- Patients with incomplete medical records or insufficient imaging
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Instrumentation with Carbon/PEEK pedicle screw system
Posterior instrumentation using a Carbon/PEEK pedicle screw system two levels above and below the affected segment(s). The medical device is a commercial product, bears a conformity marking and is used in accordance with the instructions. |
Posterior instrumentation with pedicle screw system |
|
Aktiv komparator: Instrumentation with titanium pedicle screw system
Posterior instrumentation using a titanium pedicle screw system two levels above and below the affected segment(s). The medical device is a commercial product, bears a conformity marking and is used in accordance with the instructions. |
Posterior instrumentation with pedicle screw system |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
radiation dose
Tidsramme: within 6 weeks of radiation therapy
|
The total radiation dose administered is measured in Gray |
within 6 weeks of radiation therapy
|
|
feasibility of planning the radiation therapy
Tidsramme: before radiation therapy
|
evaluated by a subjective score (0-10) stated by an independent radiooncologist using a visual analogue scale from 0 to 10 |
before radiation therapy
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
radiological visualization of the area of interest
Tidsramme: during radiation therapy
|
evaluated by a subjective score stated by an independent radiologist using a visual analogue scale from 0 to 10 |
during radiation therapy
|
|
time to recurrence
Tidsramme: up to 1 year
|
monitoring of recurrence using radiological imaging is performed routinely according to clinical standards |
up to 1 year
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Hovedetterforsker: Mazda Farshad, Prof., Balgrist University Hospital
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- Carbon PEEK
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
IPD only available to study personnel. statistical analysis will be done with encoded data only. study results will be published
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .