A simplified lung ultrasound approach to detect increased extravascular lung water in critically ill patients

Antonio Anile, Jole Russo, Giacomo Castiglione, Giovanni Volpicelli, Antonio Anile, Jole Russo, Giacomo Castiglione, Giovanni Volpicelli

Abstract

Background: The quantification of B-lines at lung ultrasonography is a valid tool to estimate the extravascular lung water (EVLW) in patients after major cardiac surgery. However, there is still uncertainty about the correlation between B-lines and EVLW in a general population of critically ill.

Aim: To evaluate a simplified lung ultrasonographic assessment as a tool to estimate the EVLW in critically ill patients admitted to a polyvalent intensive care unit (ICU).

Methods: Nineteen consecutive critically ill patients requiring mechanical ventilation and hemodynamic monitoring were enrolled. Lung ultrasonography and the thermodilution methodology (PiCCO system) were performed by two independent operators. The positive scan at lung ultrasound was defined by visualization of at least 3 B-lines. We then compared the number of chest areas positive for B-lines with the EVLW index obtained by the invasive procedure.

Results: A significant correlation was found between the number of lung quadrants positive for B-lines and EVLW indexed using both actual body weight (rho = 0.612 p = 0.0053) and predicted body weight (rho = 0.493 p = 0.032). Presence of more than 3 positive lung quadrants showed a good performance in identifying an EVLW index value >10 ml/kg of actual body weight(area under the ROC 0.894; 95% CI 0.668-0.987 p < 0.0001). Presence of of more than 4 positive lung quadrants indentified an EVLW index value >10 ml/kg of predicted body weight (area under the ROC 0.8; 95% CI 0.556-0.945 p = 0.0048).

Conclusion: A simplified lung ultrasound approach can by used as a reliable noninvasive bedside tool to predict EVLW in emergency and critically ill patients.

Figures

Fig. 1
Fig. 1
Correlation between the number of chest quadrants positive for B-lines at lung ultrasound and the values of EVLW/kg ABW. Spearman (rho) rank correlation test: sample size—19; Spearman’s coefficient of rank correlation (rho)—0.162; significance level—p = 0.0053; 95% confidence interval for rho—0.219 to 0.834
Fig. 2
Fig. 2
Correlation between the number of chest quadrants positive for B-lines at lung ultrasound and the values of EVLW/kg PBW. Spearman (rho) rank correlation test: sample size—19; Spearman’s coefficient of rank correlation (rho)—0.493; significance level—p = 0.032; 95% confidence interval for rho—0.499 to 0.774
Fig. 3
Fig. 3
Receiver operative characteristic (ROC) curve for EVLW/kg ABW
Fig. 4
Fig. 4
Receiver operative characteristic (ROC) curve for EVLW/kg PBW

References

    1. Pinsky MR. Hemodynamic monitoring in intensive care unit. Clin Chest Med. 2003;24:549–560. doi: 10.1016/S0272-5231(03)00095-9.
    1. Combes A, et al. Estimation of left ventricular systolic function by single transpulmonary thermodilution. Intensive Care Med. 2004;30:1377–1383.
    1. Bindels AJ, van der Hoeven JG, Meinders AE. Pulmonary artery wedge pressure and extravascular lung water in patients with acute cardiogenic pulmonary edema requiring mechanical ventilation. Am J Cardiol. 1999;84:1158–1163. doi: 10.1016/S0002-9149(99)00527-5.
    1. Berkowitz DM, Danai PA, Eaton S, Moss M, Martin GS. Accurate characterization of extravascular lung water in acute respiratory distress syndrome. Crit Care Med. 2008;36:1803–1809. doi: 10.1097/CCM.0b013e3181743eeb.
    1. Volpicelli G. Lung sonography. J Ultrasound Med. 2013;32:165–171. doi: 10.7863/jum.2013.32.1.165.
    1. Lichtenstein D. Comparative diagnostic performance of auscultation, chest radiography and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology. 2004;100:9–15. doi: 10.1097/00000542-200401000-00006.
    1. Volpicelli G, et al. International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38:577–591. doi: 10.1007/s00134-012-2513-4.
    1. Lichtenstein DA. Ultrasound in the management of thoracic disease. Crit Care Med. 2007;35(Suppl):S250–S261. doi: 10.1097/01.CCM.0000260674.60761.85.
    1. Lichtenstein D, Mézière G, Biderman P, Gepner A, Barré O. The comet-tail artifact. An ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med. 1997;156(5):1640–1646. doi: 10.1164/ajrccm.156.5.96-07096.
    1. Jambrik Z, Monti S, Coppola V, Agricola E, Mottola G, Miniati M, Picano E. Usefulness of ultrasound lung comets as a non radiologic sing of extravascular lung water. Am J Cardiol. 2004;93:1265–1270. doi: 10.1016/j.amjcard.2004.02.012.
    1. Agricola E, Bove T, Oppizzi M, Marino G, Zangrillo A, Margonato A, Picano E. “Ultrasound comet—tail images”: a marker of pulmonary edema. A comparative study with wedge pressure and Extravascular lung water. Chest. 2005;127:1690–1695. doi: 10.1378/chest.127.5.1690.
    1. Bouhemad B, et al. Bedside ultrasound assessment of positive end-expiratory pressure induced lung recruitment. Am J Respir Crit Care Med. 2011;183:341–347. doi: 10.1164/rccm.201003-0369OC.
    1. Bouhemad B, et al. Ultrasound assessment of antibiotic-induced reaeration in ventilator induced pneumonia. Crit Care Med. 2010;38:84–92. doi: 10.1097/CCM.0b013e3181b08cdb.
    1. Zhao Z, Jiang L, Xi X, Jiang Q, Zhu B, Wang M, Xing J, Zhang D. Prognostic value of extravascular lung water assessed with lung ultrasound score by chest sonography in patients with acute respiratory distress syndrome. BMC Pulm Med. 2015;15:98. doi: 10.1186/s12890-015-0091-2.
    1. Via G, et al. Lung ultrasound in the ICU: from diagnostic instrument to respiratory monitoring tool. Minerva Anestesiol. 2012;78:1282–1296.
    1. Volpicelli G, Skurzak S, Boero E, Carpinteri G, Tengattini M, Stefanone V, Luberto L, Anile A, Cerutti E, Radeschi G, Frascisco MF. Lung ultrasound predicts well extravascular lung water but is of limited usefulness in the prediction of wedge pressure. Anesthesiology. 2014;121:320–327. doi: 10.1097/ALN.0000000000000300.
    1. Tagami T, Sawabe M, Kushimoto S, Marik PE, Mieno MN, Kawaguchi T, Kusakabe T, Tosa R, Yokota H, Fukuda Y. Quantitative diagnosis of diffuse alveolar damage using extravascular lung water. Crit Care Med. 2013;41:2144–2150. doi: 10.1097/CCM.0b013e31828a4643.
    1. Lichtenstein DA. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill. Chest. 2015;147:1659–1670. doi: 10.1378/chest.14-1313.
    1. Caltabeloti FC, Monsel A, Arbelot C, Brisson H, Lu Q, Gu WJ, Zohu GJ, Auler JOC, Jr, Rouby JJ. Early fluid loading in acute respiratory distress syndrome with septic shock deteriorates lung aeration without impairing arterial oxygenation: a lung ultrasound observational study. Crit Care. 2014;18(3):R91. doi: 10.1186/cc13859.