Myocardial oxygenation in coronary artery disease: insights from blood oxygen level-dependent magnetic resonance imaging at 3 tesla

Jayanth R Arnold, Theodoros D Karamitsos, Paul Bhamra-Ariza, Jane M Francis, Nick Searle, Matthew D Robson, Ruairidh K Howells, Robin P Choudhury, Ornella E Rimoldi, Paolo G Camici, Adrian P Banning, Stefan Neubauer, Michael Jerosch-Herold, Joseph B Selvanayagam, Jayanth R Arnold, Theodoros D Karamitsos, Paul Bhamra-Ariza, Jane M Francis, Nick Searle, Matthew D Robson, Ruairidh K Howells, Robin P Choudhury, Ornella E Rimoldi, Paolo G Camici, Adrian P Banning, Stefan Neubauer, Michael Jerosch-Herold, Joseph B Selvanayagam

Abstract

Objectives: The purpose of this study was to assess the diagnostic accuracy of blood oxygen-level dependent (BOLD) MRI in suspected coronary artery disease (CAD).

Background: By exploiting the paramagnetic properties of deoxyhemoglobin, BOLD magnetic resonance imaging can detect myocardial ischemia. We applied BOLD imaging and first-pass perfusion techniques to: 1) examine the pathophysiological relationship between coronary stenosis, perfusion, ventricular scar, and myocardial oxygenation; and 2) evaluate the diagnostic performance of BOLD imaging in the clinical setting.

Methods: BOLD and first-pass perfusion images were acquired at rest and stress (4 to 5 min intravenous adenosine, 140 μg/kg/min) and assessed quantitatively (using a BOLD signal intensity index [stress/resting signal intensity], and absolute quantification of perfusion by model-independent deconvolution). A BOLD signal intensity index threshold to identify ischemic myocardium was first determined in a derivation arm (25 CAD patients and 20 healthy volunteers). To determine diagnostic performance, this was then applied in a separate group comprising 60 patients with suspected CAD referred for diagnostic angiography.

Results: Prospective evaluation of BOLD imaging yielded an accuracy of 84%, a sensitivity of 92%, and a specificity of 72% for detecting myocardial ischemia and 86%, 92%, and 72%, respectively, for identifying significant coronary stenosis. Segment-based analysis revealed evidence of dissociation between oxygenation and perfusion (r = -0.26), with a weaker correlation of quantitative coronary angiography with myocardial oxygenation (r = -0.20) than with perfusion (r = -0.40; p = 0.005 for difference). Hypertension increased the odds of an abnormal BOLD response, but diabetes mellitus, hypercholesterolemia, and the presence of ventricular scar were not associated with significant deoxygenation.

Conclusions: BOLD imaging provides valuable insights into the pathophysiology of CAD; myocardial hypoperfusion is not necessarily commensurate with deoxygenation. In the clinical setting, BOLD imaging achieves favorable accuracy for identifying the anatomic and functional significance of CAD.

Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.