Near-infrared spectroscopy monitoring of the collateral network prior to, during, and after thoracoabdominal aortic repair: a pilot study

C D Etz, K von Aspern, S Gudehus, M Luehr, F F Girrbach, J Ender, M Borger, F W Mohr, C D Etz, K von Aspern, S Gudehus, M Luehr, F F Girrbach, J Ender, M Borger, F W Mohr

Abstract

Objective: The aim of this study was to evaluate the feasibility of non-invasive monitoring of the paraspinous collateral network (CN) oxygenation prior to, during, and after thoracoabdominal aortic repair in a clinical series.

Methods: Near-infrared spectroscopy optodes were positioned bilaterally-over the thoracic and lumbar paraspinous vasculature-to transcutaneously monitor muscle oxygenation of the CN in 20 patients (age: 66 ± 10 years; men = 11) between September 2010 and April 2012; 15 had open thoracoabdominal aortic repair (Crawford II and III), three had thoracic endovascular aortic repair (TEVAR; Crawford I), and two had a hybrid repair (Crawford II). CN oxygenation was continuously recorded until 48 hours postoperatively.

Results: Hospital mortality was 5% (n = 1), 15% suffered ischemic spinal cord injury (SCI). Mean thoracic CN oxygenation saturation was 75.5 ± 8% prior to anesthesia (=baseline) without significant variations throughout the procedure (during non-pulsatile cooling on cardiopulmonary bypass and with aortic cross-clamping; range = 70.6-79.5%). Lumbar CN oxygenation (LbS) dropped significantly after proximal aortic cross-clamping to a minimum after 11.7 ± 4 minutes (74 ± 13% of baseline), but fully recovered after restoration of pulsatile flow to 98.5% of baseline. During TEVAR, stent-graft deployment did not significantly affect LbS. Three patients developed relevant SCI (paraplegia n = 1/paraparesis n = 2). In these patients LbS reduction after aortic cross-clamping was significantly lower compared with patients who did not experience SCI (p = .041).

Conclusions: Non-invasive monitoring of CN oxygenation prior to, during, and after thoracoabdominal aortic repair is feasible. Lumbar CN oxygenation levels directly respond to compromise of aortic blood circulation.

Keywords: Collateral network; NIRS; Non-invasive monitoring; Spinal cord ischemia; Spinal cord protection; TEVAR; Thoracoabdominal aortic repair.

Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Source: PubMed

3