Hazards to avoid in future neonatal studies of nasal high-frequency oscillatory ventilation: lessons from an early terminated trial

Hendrik S Fischer, Christoph Bührer, Christoph Czernik, Hendrik S Fischer, Christoph Bührer, Christoph Czernik

Abstract

Objective: To investigate whether nasal high-frequency oscillatory ventilation (nHFOV) started immediately after extubation of mechanically ventilated very low birth weight infants reduces the partial pressure of carbon dioxide at 72 h after extubation in comparison with nasal continuous positive airway pressure. This randomised controlled single-centre trial aimed to include 68 preterm infants at high risk of extubation failure.

Results: Implementation of the study protocol was feasible. However, from 2015 to 2017, only six patients could be recruited, leading to early termination of the trial. The slow recruitment was due to the introduction of new strategies to avoid endotracheal mechanical ventilation, which reduced the number of eligible infants. Moreover, the included infants failed their extubation more often than anticipated, thereby increasing the required sample size. Based on our single-centre experience, we provide information for study planning and discuss the specific requirements for future trial protocols on nHFOV. The extubation of high-risk infants into nHFOV could well be beneficial, but a multicentric approach is necessary to investigate this hypothesis. Trial Registration Clinicaltrials.gov NCT02340299, on 16 January 2015.

Keywords: Extubation; High-frequency ventilation; Hypercapnia; Nasal continuous positive airway pressure; Premature infant; Randomised controlled trial.

Conflict of interest statement

The authors declare that they have no competing interests.

Figures

Fig. 1
Fig. 1
Flow diagram of the progress of the two study groups through the phases of the randomised trial

References

    1. Fischer HS, Bohlin K, Bührer C, Schmalisch G, Cremer M, Reiss I, Czernik C. Nasal high-frequency oscillation ventilation in neonates: a survey in five European countries. Eur J Pediatr. 2015;174:465–471. doi: 10.1007/s00431-014-2419-y.
    1. Mukerji A, Shah PS, Shivananda S, Yee W, Read B, Minski J, Alvaro R, Fusch C. Canadian Neonatal Network I: survey of noninvasive respiratory support practices in Canadian neonatal intensive care units. Acta Paediatr. 2017;106:387–393. doi: 10.1111/apa.13644.
    1. De Luca D, Dell'Orto V. Non-invasive high-frequency oscillatory ventilation in neonates: review of physiology, biology and clinical data. Arch Dis Child Fetal Neonatal Ed. 2016;101:F565–F570. doi: 10.1136/archdischild-2016-310664.
    1. Mukerji A, Dunn M. High-frequency ventilation as a mode of noninvasive respiratory support. Clin Perinatol. 2016;43:725–740. doi: 10.1016/j.clp.2016.07.008.
    1. Colaizy TT, Younis UM, Bell EF, Klein JM. Nasal high-frequency ventilation for premature infants. Acta Paediatr. 2008;97:1518–1522. doi: 10.1111/j.1651-2227.2008.00900.x.
    1. Bottino R, Pontiggia F, Ricci C, Gambacorta A, Paladini A, Chijenas V, Liubsys A, Navikiene J, Pliauckiene A, Mercadante D, et al. Nasal high-frequency oscillatory ventilation and CO2 removal: a randomized controlled crossover trial. Pediatr Pulmonol. 2018;53:1245–1251. doi: 10.1002/ppul.24120.
    1. Czernik C, Schmalisch G, Bührer C, Proquitte H. Weaning of neonates from mechanical ventilation by use of nasopharyngeal high-frequency oscillatory ventilation: a preliminary study. J Matern Fetal Neonatal Med. 2012;25:374–378. doi: 10.3109/14767058.2011.580401.
    1. Williams RJ, Tse T, DiPiazza K, Zarin DA. Terminated trials in the results database: evaluation of availability of primary outcome data and reasons for termination. Plos ONE. 2015;10:e0127242. doi: 10.1371/journal.pone.0127242.
    1. Kribs A, Roll C, Göpel W, Wieg C, Groneck P, Laux R, Teig N, Hoehn T, Bohm W, Welzing L, et al. Nonintubated surfactant application vs conventional therapy in extremely preterm infants: a randomized clinical trial. JAMA Pediatr. 2015;169:723–730. doi: 10.1001/jamapediatrics.2015.0504.
    1. Klotz D, Schneider H, Schumann S, Mayer B, Fuchs H. Non-invasive high-frequency oscillatory ventilation in preterm infants: a randomised controlled cross-over trial. Arch Dis Child Fetal Neonatal Ed. 2018;103:F1–F5. doi: 10.1136/archdischild-2017-313190.
    1. Montecchia F, Midulla F, Papoff P. A flow-leak correction algorithm for pneumotachographic work-of-breathing measurement during high-flow nasal cannula oxygen therapy. Med Eng Phys. 2018;54:32–43. doi: 10.1016/j.medengphy.2018.02.004.
    1. Bamat N, Ghavam S, Liu Y, DeMauro SB, Jensen EA, Roberts R, Yoder BA, Kirpalani H. Reliability of a noninvasive measure of V/Q mismatch for bronchopulmonary dysplasia. Ann Am Thorac Soc. 2015;12:727–733. doi: 10.1513/AnnalsATS.201410-462OC.
    1. Ullrich TL, Czernik C, Bührer C, Schmalisch G, Fischer HS. Nasal high-frequency oscillatory ventilation impairs heated humidification: a neonatal bench study. Pediatr Pulmonol. 2017;52:1455–1460. doi: 10.1002/ppul.23824.
    1. Zhu XW, Zhao JN, Tang SF, Yan J, Shi Y. Noninvasive high-frequency oscillatory ventilation versus nasal continuous positive airway pressure in preterm infants with moderate-severe respiratory distress syndrome: a preliminary report. Pediatr Pulmonol. 2017;52:1038–1042. doi: 10.1002/ppul.23755.
    1. Fischer HS, Rimensberger PC. Early noninvasive high-frequency oscillatory ventilation in the primary treatment of respiratory distress syndrome. Pediatr Pulmonol. 2018;53:126–127. doi: 10.1002/ppul.23883.
    1. Mukerji A, Sarmiento K, Lee B, Hassall K, Shah V. Non-invasive high-frequency ventilation versus bi-phasic continuous positive airway pressure (BP-CPAP) following CPAP failure in infants <1250 g: a pilot randomized controlled trial. J Perinatol. 2017;37:49–53. doi: 10.1038/jp.2016.172.