Effectiveness of the Stewart Method in the Evaluation of Blood Gas Parameters

Mustafa Gezer, Fatih Bulucu, Kadir Ozturk, Selim Kilic, Umit Kaldirim, Yusuf Emrah Eyi, Mustafa Gezer, Fatih Bulucu, Kadir Ozturk, Selim Kilic, Umit Kaldirim, Yusuf Emrah Eyi

Abstract

Objectives: In 1981, Peter A. Stewart published a paper describing his concept for employing Strong Ion Difference. In this study we compared the HCO3 levels and Anion Gap (AG) calculated using the classic method and the Stewart method.

Methods: Four hundred nine (409) arterial blood gases of 90 patients were collected retrospectively. Some were obtained from the same patients in different times and conditions. All blood samples were evaluated using the same device (ABL 800 Blood Gas Analyzer). HCO3 level and AG were calculated using the Stewart method via the website AcidBase.org. HCO3 levels, AG and strong ion difference (SID) were calculated using the Stewart method, incorporating the parameters of age, serum lactate, glucose, sodium, and pH, etc.

Results: According to classic method, the levels of HCO3 and AG were 22.4±7.2 mEq/L and 20.1±4.1 mEq/L respectively. According to Stewart method, the levels of HCO3 and AG were 22.6±7.4 and 19.9±4.5 mEq/L respectively.

Conclusions: There was strong correlation between the classic method and the Stewart method for calculating HCO3 and AG. The Stewart method may be more effective in the evaluation of complex metabolic acidosis.

Keywords: Blood gases; Stewart method.

Figures

Figure 1
Figure 1
The Liquid-buffer system.

References

    1. Henderson LJ. The theory of neutrality regulation in the animal organism. Am J Physiol. 1907;18:427–448.
    1. Stewart PA. How to understand acid base balance. In: Stewart PA, editor. A Quantitative Acid-Base Primer for Biology and Medicine. Elsevier; New York: 1981.
    1. Fencl V, Jabor A, Kazda A, Figge J. Diagnosis of metabolic acid-base disturbances in critically ill patients. Am J Respir Crit Care Med. 2000;162:2246–2251. .
    1. Constable PD. Clinical assessment of acid-base status: comparison of the Henderson-Hasselbalch and strong ion approaches. Vet Clin Pathol. 2000;29:115–128. .
    1. Rastegar A. Clinical utility of Stewart's method in diagnosis and management of acid-base disorders. Clin J Am Soc Nephrol. 2009;4:1267–1274. .
    1. Siggaard-Andersen O, Wimberly PD, Fogh-Andersen N, Gøthgen IH. Measured and derived quantities with modern pH and blood gas equipment: calculation algorithms with 54 equations. Scand J Clin Lab Invest. 1988;48:7–15. .
    1. Figge J, Jabor A, Kazda A, Fencl V. Anion gap and hypoalbuminemia. Crit Care Med. 1998;26:1807–1810. .
    1. Memisogullari R, Ozcan ME, Celbek G, Ankaral H, Aydın Y. Correlation of bicarbonate values measured with direct enzymatic method and blood gas analysis devices. Turk J Biochem. 2011;36:270–272.
    1. Story DA, Poustie S. Agreement between two plasma bicarbonate assays in critically ill patients. Anaesth Intensive Care. 2000;28:399–402.
    1. Hatherill M, Waggie Z, Purves L, Reynolds L, Argent A. Correction of the anion gap for albumin in order to detect occult tissue anions in shock. Arch Dis Child. 2002;87:526–529. .
    1. Morgan TJ, Clark C, Endre ZH. Accuracy of base excess-an in vitro evaluation of the Van Slyke equation. Crit Care Med. 2000;28:2932–2936. .

Source: PubMed

3