Refractive lenticule extraction small incision lenticule extraction: A new refractive surgery paradigm

Sri Ganesh, Sheetal Brar, Raghavender Reddy Arra, Sri Ganesh, Sheetal Brar, Raghavender Reddy Arra

Abstract

Small incision lenticule extraction (SMILE), a variant of refractive lenticule extraction technology is becoming increasingly popular, as a flapless and minimally invasive form of laser vision correction (LVC) for the treatment of myopia and myopic astigmatism. This review aims at summarizing the principles, surgical technique, and clinical outcomes in terms of visual and refractive results, safety, efficacy, postoperative dry eye, aberrations, and biomechanics of SMILE and its comparison with other conventional techniques of LVC, such as laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK). Recent advancements in the laser frequency and energy delivery patterns, instrumentation, and surgical techniques have shown significant improvement in the visual recovery and outcomes after SMILE, compared to the initial results published by Sekundo and Shah et al. Most of the recently published literature on long-term outcomes of SMILE shows excellent stability of the procedure, especially for higher myopia. In terms of the postoperative dry eye, SMILE shows a clear advantage over LASIK as numerous studies have shown significant differences about the Schirmer's, Tear film break up time, corneal sensitivity, and corneal nerve regeneration to be better following SMILE compared to LASIK. There is some evidence that since the Bowman's membrane (BM) and the anterior lamellae remain intact after SMILE, this may be a potential advantage for corneal biomechanics over LASIK and PRK where the BM is either severed or ablated, respectively, however, the data on biomechanics are inconclusive at present. Overall, this procedure has proved to be promising, delivering equivalent, or better visual and refractive results to LASIK and providing clear advantage in terms of being a flapless, minimally invasive procedure with minimal pain and postoperative discomfort thus offering high patient satisfaction.

Conflict of interest statement

Dr. Sri Ganesh is a consultant for Carl Zeiss Meditec, Germany and receives travel grants from the company.

Figures

Figure 1
Figure 1
The lenticule cut (1) is performed (the underside of the lenticule), followed by the lenticule sidecuts (2). Next, the cap interface (3) is created (the upper side of the lenticule), and finally a 2–3 mm small incision (4) is created superotemporally. The lenticule interfaces are dissected using a flap separator and the lenticule is extracted manually, all via the small incision (Reproduced after permission from Prof Dan Reinstein)
Figure 2
Figure 2
Clinical pictures of corneal interface in retroillumination after dilatation, on 1st day postoperation in a patient who underwent small incision lenticule extraction with conventional dissection technique in the right eye (a) and lenticuloschisis (b) in the contralateral eye by the same surgeon in the same sitting for similar degree of myopia (−4.00 D both eyes). The corneal interface showed more roughness in the eye with dissection and showed prominence of the cap edge (white arrow) (a), whereas it was smoother in the lenticuloschisis eye (b). Patient also reported better clarity with the eye with lenticuloschisis. (Reproduced after permission from Journal of Refractive Surgery)
Figure 3
Figure 3
Anterior segment Optical Coherence Tomography of an eye showing retained lenticular fragment following a failed primary small incision lenticule extraction procedure
Figure 4
Figure 4
(a) Preoperative limbal marking with the Ganesh bubble marker (Epsilon Surgical, Chino, CA, USA). This instrument uses three marks on the limbus at 0°, 90°, and 180°, extending 2 mm toward the center of the cornea, which are easy to visualize while the eye is being docked. (b) Method of manual cyclotorsion compensation by a gentle rotation of the cone while holding the same at the attachment of the tube to the cone. (c) Position of the limbal marks (red arrows) under suction “ON” condition without cyclotorsion compensation before starting the laser, showing approximately 12° of cyclotorsion. (d) Final position of the limbal marks after manual compensation of the cyclotorsion error (alignment with the horizontal axis of the eyepiece reticule). Delivery of the laser follows this (reproduced after permission from Journal of Refractive Surgery)
Figure 5
Figure 5
Clinical Photographs of an eye at 15 days (a) and 1 year (b) following FILI for + 4.5 D of hyperopia showing well centered and clear lenticule at the last follow-up

References

    1. Sekundo W, Kunert K, Russmann C, Gille A, Bissmann W, Stobrawa G, et al. First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: Six-month results. J Cataract Refract Surg. 2008;34:1513–20.
    1. Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: Results of a 6 month prospective study. Br J Ophthalmol. 2011;95:335–9.
    1. Krueger RR, Juhasz T, Gualano A, Marchi V. The picosecond laser for nonmechanical laser in situ keratomileusis. J Refract Surg. 1998;14:467–9.
    1. Ito M, Quantock AJ, Malhan S, Schanzlin DJ, Krueger RR. Picosecond laser in situ keratomileusis with a 1053-nm nd: YLF laser. J Refract Surg. 1996;12:721–8.
    1. Heisterkamp A, Mamom T, Kermani O, Drommer W, Welling H, Ertmer W, et al. Intrastromal refractive surgery with ultrashort laser pulses: In vivo study on the rabbit eye. Graefes Arch Clin Exp Ophthalmol. 2003;241:511–7.
    1. Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR. First clinical results with the femtosecond neodynium-glass laser in refractive surgery. J Refract Surg. 2003;19:94–103.
    1. Reinstein DZ, Archer TJ, Gobbe M, Johnson N. Accuracy and reproducibility of artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms. J Refract Surg. 2010;26:107–19.
    1. Blum M, Kunert KS, Engelbrecht C, Dawczynski J, Sekundo W. Femtosecond lenticule extraction (FLEx) – Results after 12 months in myopic astigmatism. Klin Monbl Augenheilkd. 2010;227:961–5.
    1. Vestergaard A, Ivarsen A, Asp S, Hjortdal JØ. Femtosecond (FS) laser vision correction procedure for moderate to high myopia: A prospective study of reLEx ® flex and comparison with a retrospective study of FS-laser in situ keratomileusis. Acta Ophthalmol. 2013;91:355–62.
    1. Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011;37:127–37.
    1. Reinstein DZ, Archer TJ, Gobbe M. Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes. Eye Vis (Lond) 2014;1:3.
    1. Pande M, Hillman JS. Optical zone centration in keratorefractive surgery. Entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometric corneal center? Ophthalmology. 1993;100:1230–7.
    1. Vetter JM, Holzer MP, Teping C, Weingärtner WE, Gericke A, Stoffelns B, et al. Intraocular pressure during corneal flap preparation: Comparison among four femtosecond lasers in porcine eyes. J Refract Surg. 2011;27:427–33.
    1. Liu YC, Mehta JS. Surgical instruments for small incision lenticule extraction (SMILE) Expert Rev Ophthalmol. 2016;11:171–2.
    1. Ganesh S, Brar S, Gupta R, Sinha N. A comparative study of patients undergoing ReLEX ® smile with one eye interface wash and the contralateral eye without interface wash. EC Ophthalmol. 2017;5:3–10.
    1. Ganesh S, Brar S. Lenticuloschisis: A “No dissection” technique for lenticule extraction in small incision lenticule extraction. J Refract Surg. 2017;33:563–6.
    1. Vestergaard AH. Past and present of corneal refractive surgery: A retrospective study of long-term results after photorefractive keratectomy and a prospective study of refractive lenticule extraction. Acta Ophthalmol. 2014;92:1–21.
    1. Kamiya K, Shimizu K, Igarashi A, Kobashi H. Visual and refractive outcomes of femtosecond lenticule extraction and small-incision lenticule extraction for myopia. Am J Ophthalmol. 2014;157:128–34.e2.
    1. Hjortdal JØ, Vestergaard AH, Ivarsen A, Ragunathan S, Asp S. Predictors for the outcome of small-incision lenticule extraction for myopia. J Refract Surg. 2012;28:865–71.
    1. Ganesh S, Gupta R. Comparison of visual and refractive outcomes following femtosecond laser- assisted lasik with smile in patients with myopia or myopic astigmatism. J Refract Surg. 2014;30:590–6.
    1. Aǧca A, Demirok A, Cankaya Kİ, Yaşa D, Demircan A, Yildirim Y, et al. Comparison of visual acuity and higher-order aberrations after femtosecond lenticule extraction and small-incision lenticule extraction. Cont Lens Anterior Eye. 2014;37:292–6.
    1. Pedersen IB, Ivarsen A, Hjortdal J. Three-year results of small incision lenticule extraction for high myopia: Refractive outcomes and aberrations. J Refract Surg. 2015;31:719–24.
    1. Blum M, Täubig K, Gruhn C, Sekundo W, Kunert KS. Five-year results of small incision lenticule extraction (ReLEx SMILE) Br J Ophthalmol. 2016;100:1192–5.
    1. Han T, Zheng K, Chen Y, Gao Y, He L, Zhou X, et al. Four-year observation of predictability and stability of small incision lenticule extraction. BMC Ophthalmol. 2016;16:149.
    1. Yıldırım Y, Alagöz C, Demir A, Ölçücü O, Özveren M, Aǧca A, et al. Long-term results of small-incision lenticule extraction in high myopia. Turk J Ophthalmol. 2016;46:200–4.
    1. Wu W, Wang Y, Zhang H, Zhang J, Li H, Dou R, et al. One-year visual outcome of small incision lenticule extraction (SMILE) surgery in high myopic eyes: Retrospective cohort study. BMJ Open. 2016;6:e010993.
    1. Ganesh S, Brar S, Relekar KJ. Epithelial thickness profile changes following small incision refractive lenticule extraction (SMILE) for myopia and myopic astigmatism. J Refract Surg. 2016;32:473–82.
    1. Khalifa MA, Ghoneim AM, Shaheen MS, Piñero DP. Vector analysis of astigmatic changes after small-incision lenticule extraction and wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg. 2017;43:819–24.
    1. Kobashi H, Kamiya K, Igarashi A, Takahashi M, Shimizu K. Two years results of small incision lenticule extraction and wavefront guided laser in situ keratomileusis for Myopia. Acta Ophthalmologica. 2017 Jun 20;
    1. Cai WT, Liu QY, Ren CD, Wei QQ, Liu JL, Wang QY, et al. Dry eye and corneal sensitivity after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis: A meta-analysis. Int J Ophthalmol. 2017;10:632–8.
    1. Kanellopoulos AJ. Topography-guided LASIK versus small incision lenticule extraction (SMILE) for myopia and myopic astigmatism: A Randomized, prospective, contralateral eye study. J Refract Surg. 2017;33:306–12.
    1. Zhang Y, Shen Q, Jia Y, Zhou D, Zhou J. Clinical outcomes of SMILE and FS-LASIK used to treat myopia: A meta-analysis. J Refract Surg. 2016;32:256–65.
    1. Ganesh S, Brar S, Patel U. Comparison of ReLEx SMILE and PRK in terms of visual and refractive outcomes for the correction of low myopia. International Ophthalmology. 2017 May;27:1–8.
    1. Yildirim Y, Olcucu O, Alagoz C, Basci A, Agca A, Yasa D, et al. Visual and refractive outcomes of photorefractive keratectomy and small incision lenticule extraction (SMILE) for myopia. J Refract Surg. 2016;32:604–10.
    1. Reinstein DZ, Archer TJ, Gobbe M. Lenticule thickness readout for small incision lenticule extraction compared to Artemis three-dimensional very high-frequency digital ultrasound stromal measurements. J Refract Surg. 2014;30:304–9.
    1. Reinstein DZ, Silverman RH, Raevsky T, Simoni GJ, Lloyd HO, Najafi DJ, et al. Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis. J Refract Surg. 2000;16:414–30.
    1. Roberts C. The cornea is not a piece of plastic. J Refract Surg. 2000;16:407–13.
    1. Ivarsen A, Asp S, Hjortdal J. Safety and complications of more than 1500 small-incision lenticule extraction procedures. Ophthalmology. 2014;121:822–8.
    1. Reinstein DZ, Archer TJ, Gobbe M. Combined corneal topography and corneal wavefront data in the treatment of corneal irregularity and refractive error in LASIK or PRK using the carl zeiss meditec MEL 80 and CRS-master. J Refract Surg. 2009;25:503–15.
    1. Dong Z, Zhou X. Irregular astigmatism after femtosecond laser refractive lenticule extraction. J Cataract Refract Surg. 2013;39:952–4.
    1. Reinstein DZ, Archer TJ, Dickeson ZI, Gobbe M. Transepithelial phototherapeutic keratectomy protocol for treating irregular astigmatism based on population epithelial thickness measurements by artemis very high-frequency digital ultrasound. J Refract Surg. 2014;30:380–7.
    1. Moshirfar M, Albarracin JC, Desautels JD, Birdsong OC, Linn SH, Hoopes PC, Sr, et al. Ectasia following small-incision lenticule extraction (SMILE): A review of the literature. Clin Ophthalmol. 2017;11:1683–8.
    1. Mattila JS, Holopainen JM. Bilateral ectasia after femtosecond laser-assisted small incision lenticule extraction (SMILE) J Refract Surg. 2016;32:497–500.
    1. El-Naggar MT. Bilateral ectasia after femtosecond laser-assisted small-incision lenticule extraction. J Cataract Refract Surg. 2015;41:884–8.
    1. Wang Y, Cui C, Li Z, Tao X, Zhang C, Zhang X, et al. Corneal ectasia 6.5 months after small-incision lenticule extraction. J Cataract Refract Surg. 2015;41:1100–6.
    1. Sachdev G, Sachdev MS, Sachdev R, Gupta H. Unilateral corneal ectasia following small-incision lenticule extraction. J Cataract Refract Surg. 2015;41:2014–8.
    1. Chernyak DA. Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery. J Cataract Refract Surg. 2004;30:633–8.
    1. Chan TC, Ng AL, Cheng GP, Wang Z, Ye C, Woo VC, et al. Vector analysis of astigmatic correction after small-incision lenticule extraction and femtosecond-assisted LASIK for low to moderate myopic astigmatism. Br J Ophthalmol. 2016;100:553–9.
    1. Zhang J, Wang Y, Chen X. Comparison of moderate- to high-astigmatism corrections using waveFront-guided laser in situ keratomileusis and small-incision lenticule extraction. Cornea. 2016;35:523–30.
    1. Kunert KS, Russmann C, Blum M, Sluyterman VL. Vector analysis of myopic astigmatism corrected by femtosecond refractive lenticule extraction. J Cataract Refract Surg. 2013;39:759–69.
    1. Shen EP, Chen WL, Hu FR. Manual limbal markings versus iris-registration software for correction of myopic astigmatism by laser in situ keratomileusis. J Cataract Refract Surg. 2010;36:431–6.
    1. Ganesh S, Brar S, Pawar A. Results of intraoperative manual cyclotorsion compensation for myopic astigmatism in patients undergoing small incision lenticule extraction (SMILE) J Refract Surg. 2017;33:506–12.
    1. Agca A, Ozgurhan EB, Yildirim Y, Cankaya KI, Guleryuz NB, Alkin Z, et al. Corneal backscatter analysis by in vivo confocal microscopy: Fellow eye comparison of small incision lenticule extraction and femtosecond laser-assisted LASIK. J Ophthalmol. 2014;2014:265012.
    1. Yao P, Zhao J, Li M, Shen Y, Dong Z, Zhou X. Microdistortions in Bowman's layer following femtosecond laser small incision lenticule extraction observed by Fourier-domain OCT. J Refract Surg. 2013;29:668–74.
    1. Sekundo W, Gertnere J, Bertelmann T, Solomatin I. One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE) Graefes Arch Clin Exp Ophthalmol. 2014;252:837–43.
    1. Kobashi H, Kamiya K, Shimizu K. Dry eye after small incision lenticule extraction and femtosecond laser-assisted LASIK: Meta-analysis. Cornea. 2017;36:85–91.
    1. Shen Z, Zhu Y, Song X, Yan J, Yao K. Dry eye after small incision lenticule extraction (SMILE) versus femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for myopia: A Meta-analysis. PLoS One. 2016;11:e0168081.
    1. He M, Huang W, Zhong X. Central corneal sensitivity after small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: A meta-analysis of comparative studies. BMC Ophthalmol. 2015;15:141.
    1. Shen Z, Shi K, Yu Y, Yu X, Lin Y, Yao K, et al. Small incision lenticule extraction (SMILE) versus femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for myopia: A Systematic review and meta-analysis. PLoS One. 2016;11:e0158176.
    1. Reinstein DZ, Archer TJ, Gobbe M, Bartoli E. Corneal sensitivity after small-incision lenticule extraction and laser in situ keratomileusis. J Cataract Refract Surg. 2015;41:1580–7.
    1. Demirok A, Ozgurhan EB, Agca A, Kara N, Bozkurt E, Cankaya KI, et al. Corneal sensation after corneal refractive surgery with small incision lenticule extraction. Optom Vis Sci. 2013;90:1040–7.
    1. Li M, Niu L, Qin B, Zhou Z, Ni K, Le Q, et al. Confocal comparison of corneal reinnervation after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) PLoS One. 2013;8:e81435.
    1. Vestergaard AH, Grønbech KT, Grauslund J, Ivarsen AR, Hjortdal JØ. Subbasal nerve morphology, corneal sensation, and tear film evaluation after refractive femtosecond laser lenticule extraction. Graefes Arch Clin Exp Ophthalmol. 2013;251:2591–600.
    1. Randleman JB, Dawson DG, Grossniklaus HE, McCarey BE, Edelhauser HF. Depth-dependent cohesive tensile strength in human donor corneas: Implications for refractive surgery. J Refract Surg. 2008;24:S85–9.
    1. Wang D, Liu M, Chen Y, Zhang X, Xu Y, Wang J, et al. Differences in the corneal biomechanical changes after SMILE and LASIK. J Refract Surg. 2014;30:702–7.
    1. Wu D, Wang Y, Zhang L, Wei S, Tang X. Corneal biomechanical effects: Small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refract Surg. 2014;40:954–62.
    1. Chen M, Yu M, Dai J. Comparison of biomechanical effects of small incision lenticule extraction and laser-assisted subepithelial keratomileusis. Acta Ophthalmol. 2016;94:e586–e591.
    1. Dou R, Wang Y, Xu L, Wu D, Wu W, Li X, et al. Comparison of corneal biomechanical characteristics after surface ablation refractive surgery and novel lamellar refractive surgery. Cornea. 2015;34:1441–6.
    1. Kamiya K, Shimizu K, Igarashi A, Kobashi H, Sato N, Ishii R, et al. Intraindividual comparison of changes in corneal biomechanical parameters after femtosecond lenticule extraction and small-incision lenticule extraction. J Cataract Refract Surg. 2014;40:963–70.
    1. Siedlecki J, Luft N, Kook D, Wertheimer C, Mayer WJ, Bechmann M, et al. Enhancement after myopic small incision lenticule extraction (SMILE) using surface ablation. J Refract Surg. 2017;33:513–8.
    1. Riau AK, Ang HP, Lwin NC, Chaurasia SS, Tan DT, Mehta JS, et al. Comparison of four different visuMax circle patterns for flap creation after small incision lenticule extraction. J Refract Surg. 2013;29:236–44.
    1. Donate D, Thaëron R. Preliminary evidence of successful enhancement after a primary SMILE procedure with the sub-cap-lenticule-extraction technique. J Refract Surg. 2015;31:708–10.
    1. Ganesh S, Brar S. Clinical outcomes of small incision lenticule extraction with accelerated cross-linking (ReLEx SMILE xtra) in patients with thin corneas and borderline topography. J Ophthalmol. 2015;2015:263412.
    1. Barraquer JI. Keratomileusis and keratophakia. Bogota: Instituto Barraquer de America; 1980.
    1. Pradhan KR, Reinstein DZ, Carp GI, Archer TJ, Gobbe M, Gurung R, et al. Femtosecond laser-assisted keyhole endokeratophakia: Correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor. J Refract Surg. 2013;29:777–82.
    1. Ganesh S, Brar S, Rao PA. Cryopreservation of extracted corneal lenticules after small incision lenticule extraction for potential use in human subjects. Cornea. 2014;33:1355–62.
    1. Ganesh S, Brar S. Femtosecond intrastromal lenticular implantation combined with accelerated collagen cross-linking for the treatment of keratoconus – Initial clinical result in 6 eyes. Cornea. 2015;34:1331–9.
    1. Bhandari V, Ganesh S, Brar S, Pandey R. Application of the SMILE-derived glued lenticule patch graft in microperforations and partial-thickness corneal defects. Cornea. 2016;35:408–12.
    1. Reinstein DZ, Pradhan KR, Carp GI, Archer TJ, Gobbe M, Sekundo W, et al. Small incision lenticule extraction (SMILE) for hyperopia: Optical zone centration. J Refract Surg. 2017;33:150–6.

Source: PubMed

3
Abonnere