- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT02608632
HFS-guided Renal Ablation for Improving Outcome of Renal Denervation Procedure
High Frequency Guided Renal Artery Denervation for Improving Outcome of Renal Ablation Procedure
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy (Oczekiwany)
Faza
- Faza 2
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Krasnoyarsk, Federacja Rosyjska
- Federal Center of Cardiovascular surgery
-
Krasnoyarsk, Federacja Rosyjska
- Regional Hospital
-
Moscow, Federacja Rosyjska
- Federal Center of Prophylactic Medicine
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Office-based systolic blood pressure of ≥140/90 mm Hg and <160/100 mm Hg (moderate resistant hypertension) or ≥160/100 mm Hg (severe resistant hypertension), despite treatment with 3 antihypertensive drugs (including a diuretic).
- A glomerular filtration rate ≥45 mL/min/1⋅73 m2, with modification of diet using a renal disease formula.
Exclusion Criteria:
- Secondary causes of hypertension
- Severe renal artery stenosis or dual renal arteries
- Congestive heart failure
- Left ventricular ejection fraction <35%
- Previous renal artery stenting or angioplasty
- Type 1 diabetes mellitus
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Group 1 (RDN guided by HFS)
Renal arteries were assessed for suitability of ablation by renal angiography. The real-time 3-dimensional aorta-renal artery maps were reconstructed with the use of navigation system and ablation catheter via femoral artery access. After that high-frequency stimulation (HFS) was used before the initial and after each radiofrequency (RF) delivery within the renal artery. RDN was considered to have been achieved when the sudden increase of blood pressure (> 15 mm Hg from invasive arterial monitoring) was eliminated in response to HFS. RF ablations of 8-12 watts (impedance drop >10%) were applied discretely from the first distal main renal artery bifurcation all the way back to the ostium. The duration of each RF delivery was 60-120 sec, and up to 6 lesions (separated by > 5 mm) were performed both longitudinally and rotationally within each renal artery. |
|
|
Aktywny komparator: Group 2 (RDN as standard procedure)
Renal arteries were assessed for suitability of ablation by renal angiography. The real-time 3-dimensional aorta-renal artery maps were reconstructed with the use of navigation system and ablation catheter via femoral artery access. RF ablations of 8-12 watts (impedance drop >10%) were applied discretely from the first distal main renal artery bifurcation all the way back to the ostium. The duration of each RF delivery was 60-120 sec, and up to 6 lesions (separated by > 5 mm) were performed both longitudinally and rotationally within each renal artery. High-frequency stimulation (HFS) was performed before and after RDN to just to verify the response of BP |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
number of responders to renal denervation procedure
Ramy czasowe: 12 month
|
12 month
|
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
complications rate
Ramy czasowe: 12 month
|
12 month
|
|
cross-over rate
Ramy czasowe: 12 month
|
12 month
|
Współpracownicy i badacze
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 7452RDNHFS
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Renal denervation guided by HFS
-
University of AdelaideNieznanyNiekontrolowane nadciśnienieAustralia
-
Meshalkin Research Institute of Pathology of CirculationZakończonyPrzewlekłe niedokrwienie kończyn dolnych | Miażdżyca tętnic piszczelowych | Uszkodzenie nie większe niż dwie tętnice piszczelowe | Stenookluzyjne uszkodzenie tętnic piszczelowychFederacja Rosyjska