Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients

Arash Frouzan, Kambiz Masoumi, Ali Delirroyfard, Behnaz Mazdaie, Elnaz Bagherzadegan, Arash Frouzan, Kambiz Masoumi, Ali Delirroyfard, Behnaz Mazdaie, Elnaz Bagherzadegan

Abstract

Background: Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures.

Objective: The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients.

Methods: This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity.

Results: The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures.

Conclusion: The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures.

Keywords: Long Bone Fractures; Lower Extremity; Plain Radiography; Ultrasound; Upper Extremity.

Conflict of interest statement

Conflict of Interest: There is no conflict of interest to be declared.

References

    1. Smith GS, Barss PG. Unintentional injuries in developing countries: the epidemiology of a neglected problem. Epidemiol Rev. 1991;13:228–66. doi: 10.1093/oxfordjournals.epirev.a036070.
    1. Murray CJ, Lopez AD. Mortality by cause for eight regions of the world: Global Burden of Disease Study. Lancet. 1997;349(9061):1269–76. doi: 10.1016/S0140-6736(96)07493-4.
    1. Leigh J, Macaskill P, Kuosma E, Mandryk J. Global burden of disease and injury due to occupational factors. Epidemiology. 1999;10(5):626–31.
    1. Green DP, Rockwood CA, Bucholz RW, Heckman JD, Tornetta P. Rockwood and Green’s Fractures in Adults. Lippincott Williams & Wilkins; 2010.
    1. Forouzanfar MH, Sepanlou SG, Shahraz S, Dicker D, Naghavi P, Pourmalek F, et al. Evaluating causes of death and morbidity in Iran, global burden of diseases, injuries, and risk factors study 2010. Arch Iran Med. 2014;17(5):304–20. 0141705/AIM.004.
    1. Yildarim A, Unluner EE, Vandenberk N, Karagoz A. The role of bedside ultrasonography for occult scaphoid fractures in the emergency department. Ulus Travma Acil Cerrahi Derg. 2013;19(3):241–5. doi: 10.5505/tjtes.2013.64927.
    1. Barata L, Spencer R, suppiah A, Raio C, Ward MF, Sama A. Emergency ultrasound in the detection of pediatric long-bone fractures. Pediatr Emerg Care. 2012;28(11):1154–7. doi: 10.1097/PEC.0b013e3182716fb7.
    1. McNeil CR, McManus J, Mehta S. The Accuracy of protable ultrasonography to diagnose fractures in an austere environment. Prehosp Emerg Care. 2009;13(1):50–2. doi: 10.1080/10903120802474513.
    1. Wong CE, Ang AS, Ng KC. Ultrasound as an aid for reduction of pediatric forearm fractures. Int J Emerg Med. 2008;1(4):267–71. doi: 10.1007/s12245-008-0072-9.
    1. Keen CE. Point of care ultrasound useful for fracture diagnosis. 2010
    1. Sinha TP, Bhoi S, Kumar S, Ramchandani R, Goswami A, Kurrey L, et al. Diagnostic accuracy of bedside emergency ultrasound screening of fracture in pediatric trauma. J Emerg Trauma Shock. 2011;4(4):443–5. doi: 10.4103/0974-2700.86625.
    1. Marshburn TH, Legome E, Sargsyan A, Li SM, Noble VA, Dulchavsky SA. Goal-directed ultrasound in the detection of long-bone fractures. J Trauma. 2003;57(2):329–32. doi: 10.1097/01.TA.0000088005.35520.CB.
    1. Mortiz JD, Berthold LD, Soenksen SF, Alzen GF. Ultrasound in diagnosis of fracture in children: Unnecessary harassment or useful addition to X-ray? Ultraschall Med. 2008;29(3):267–74. doi: 10.1055/s-2008-1027329.
    1. Patel DD, Blumberg SM, Crain EF. The utility of bedside ultrasonography in identifying fractures and guiding fracture reduction in children. Pediatr Emerg Care. 2009;25(4):221–5. doi: 10.1097/PEC.0b013e31819e34f7.
    1. Eckert K, Ackermann O, Schweiger B, Radelff E, Liedgens P. Ultrasound as a viable alternative to standard X-rays for the diagnosis of distal forearm fracture in children. Z Orthop Unfall. 2012;150(4):409–14. doi: 10.1055/s-0032-1314974.
    1. Joshi N, Lira A, Mehta N, Paladino L, Sinert R. Diagnostic accuracy of history, physical examination and bedseide ultrasound for diagnosis of exterimity fractures in the emergency department: a systemic review. Acad Emerg Med. 2013;20(1):1–15. doi: 10.1111/acem.12058.
    1. Rabiner JE, Khine H, Avner JR, Freidman LM, Tsung JW. Accademy of point of care ultrasonography for diagnosis of elbow fractures in children. Ann Emerge Med. 2013;61(1):9–17. doi: 10.1016/j.annemergmed.2012.07.112.
    1. Bolandparvaz S, Moharamzadeh P, Jamali K, Pouraghaei M, Fadaie M, Sefidbakht S, et al. Comparing diagnostic accuracy of bedside ultrasound and radiography for bone fracture screening in multiple trauma patients at the ED. Am J Emerg Med. 2013;31(11):1583–5. doi: 10.1016/j.ajem.2013.08.005.
    1. Hübner U, Schlicht W, Outzen S, Barthel M, Halsband H. Ultrasound in the diagnosis of fractures in children. J Bone Joint Surg Br. 2000;82(8):1170–3. doi: 10.1302/0301-620X.82B8.10087.
    1. Waterbrook AL, Adhikari S, Stolz U, Adrion C. The accuracy of point-of-care ultrasound to diagnose long bone fractures in the ED. Am J Emerg Med. 2013;31(9):1352–6. doi: 10.1016/j.ajem.2013.06.006.
    1. Herren C, Sobottke R, Ringe MJ, Visel D, Graf M, Müller D, et al. Ultrasound-guided diagnosis of fractures of the distal forearm in children. Orthop Traumatol Surg Res. 2015;101(4):501–5. doi: 10.1016/j.otsr.2015.02.010.
    1. Neri E, Barbi E, Rabach I, Zanchi C, Norbedo S, Ronfani L, et al. Diagnostic accuracy of ultrasonography for hand bony fractures in paediatric patients. Arch Dis Child. 2014;99(12):1087–90. doi: 10.1136/archdischild-2013-305678.

Source: PubMed

3
Subskrybuj