Secondary Vitrectomy with Internal Limiting Membrane Plug due to Persistent Full-Thickness Macular Hole OCT-Angiography and Microperimetry Features: Case Series
Dominika Wrzesińska, Katarzyna Nowomiejska, Dominika Nowakowska, Mario Damiano Toro, Vincenza Bonfiglio, Michele Reibaldi, Teresio Avitabile, Robert Rejdak, Dominika Wrzesińska, Katarzyna Nowomiejska, Dominika Nowakowska, Mario Damiano Toro, Vincenza Bonfiglio, Michele Reibaldi, Teresio Avitabile, Robert Rejdak
Abstract
Purpose: To study the features in OCT-angiography and microperimetry in eyes with persistent full-thickness macular hole (FTMH) closed with the secondary plana vitrectomy (PPV) with autologous internal limiting membrane (ILM) plug.
Methods: Secondary PPV was performed with closing the persistent FTMH with ILM plug, C3F8 tamponade, and face-down positioning. Four patients were followed for 6 months with best corrected visual acuity (BCVA) measurement, SD-OCT and OCT-A, and microperimetry. The results were compared with the fellow eye; in two patients, it was the healthy eye, and in two remaining eyes, successfully closed FTMH after primary PPV.
Results: ILM flap was integrated in all cases with V-shape of closure, and atrophy was found in one case, with the largest diameter of FTMH. BCVA improved in two cases and remained the same in two cases. In OCT-A, the area of foveal avascular zone (FAZ) was larger, and foveal vessel density (FVDS) was smaller in eyes after secondary PPV in comparison to fellow eyes. In microperimetry, retinal sensitivity was lower in eyes after secondary PPV, and eccentric fixation was found in 2 of 4 patients.
Conclusion: Although the anatomical results of repeated surgeries of FTMH with ILM plug are favorable, visual function results may be limited. Secondary closure of FTMH with ILM plug may lead to atrophy, changes in the macular vasculature, and eccentric fixation. The trial is registered with NCT03701542.
Conflict of interest statement
The authors declare that they have no conflicts of interest.
Copyright © 2020 Dominika Wrzesińska et al.
Figures
References
- Wrzesińska D., Nowomiejska K., Nowakowska D., et al. Vertical and horizontal m-charts and microperimetry for assessment of the visual function in patients after vitrectomy with ilm peeling due to stage 4 macular hole. Journal of Ophthalmology. 2019;2019 doi: 10.1155/2019/4975973.4975973
- Reibaldi M., Rizzo S., Avitabile T., et al. Iatrogenic retinal breaks in 25-gauge vitrec to my under air compared with the standard 25-gauge system for macular diseases. Retina. 2014;34(8):1617–1622. doi: 10.1097/iae.0000000000000112.
- Reid G. A., McDonagh N., Wright D. M., Yek J. T. O., Essex R. W., Lois N. First failed macular hole surgery or reopening of a previously closed hole. Retina. 2020;40(1):1–15. doi: 10.1097/iae.0000000000002564.
- Kelly N. E., Wendel R. T. Vitreous surgery for idiopathic macular holes. Archives of Ophthalmology. 1991;109(5):654–659. doi: 10.1001/archopht.1991.01080050068031.
- Ma F. Y., Xi R. J., Chen P. F., Hao Y. H. Free autologous internal limiting membrane transplantation in the treatment of large macular hole. International Journal of Ophthalmology. 2019;12(5):848–851. doi: 10.18240/ijo.2019.05.24.
- Russo A., Ragusa M., Barbagallo C., et al. MiRNAs in the vitreous humor of patients affected by idiopathic epiretinal membrane and macular hole. PLoS One. 2017;22e0174297
- Jenisch T. M., Zeman F., Koller M., Märker D. A., Helbig H., Herrmann W. A. Macular hole surgery: an analysis of risk factors for the anatomical and functional outcomes with a special emphasis on the experience of the surgeon. Clinical Ophthalmology. 2017;11:1127–1134. doi: 10.2147/opth.s125561.
- Yek J. T. O., Hunyor A. P., Campbell W. G., et al. Outcomes of eyes with failed primary surgery for idiopathic macular hole. Ophthalmology Retina. 2018;2(8):757–764. doi: 10.1016/j.oret.2017.10.012.
- Giansanti F., Tartaro R., Caporossi T. An internal limiting membrane plug and gas endotamponade for recurrent or persistent macular hole. Journal of Ophthalmology. 2019;2019 doi: 10.1155/2019/6051724.6051724
- Dai Y., Dong F., Zhang X., Yang Z. Internal limiting membrane transplantation for unclosed and large macular holes. Graefe’s Archive for Clinical and Experimental Ophthalmology. 2016;254(11):2095–2099. doi: 10.1007/s00417-016-3461-4.
- Bottoni F., Parrulli S., Mete M., et al. Large idiopathic macular hole surgery: remodelling of outer retinal layers after traditional internal limiting membrane peeling or inverted flap technique. Ophthalmologica. 2020;243(5):p. 334. doi: 10.1159/000505926.
- Ghassemi F., Khojasteh H., Khodabande A., et al. Comparison of three different techniques of inverted internal limiting membrane flap in treatment of large idiopathic full-thickness macular hole. Clinical Ophthalmology. 2019;13:2599–2606. doi: 10.2147/opth.s236169.
- Bonińska K., Nawrocki J., Michalewska Z. Mechanism of “flap closure” after the inverted internal limiting membrane flap technique. Retina. 2018;38(11):2184–2189.
- Wendel R. T., Patel A. C., Kelly N. E., Salzano T. C., Wells J. W., Novack G. D. Vitreous surgery for macular holes. Ophthalmology. 1993;100(11):1671–1676. doi: 10.1016/s0161-6420(93)31419-3.
- Morizane Y., Shiraga F., Kimura S., et al. Autologous transplantation of the internal limiting membrane for refractory macular holes. American Journal of Ophthalmology. 2014;157(4):861–869. doi: 10.1016/j.ajo.2013.12.028.
- Ichhpujani P., Spaeth L. G., Yanoff M. Expert Techniques in Ophthalmic Surgery. 2nd. New Delhi, India: Jaypee Brothers Medical Publishers (P) Ltd; 2019.
- Reibaldi M., Avitabile T., Longo A., et al. Correlation of preoperative retinal pigment epithelium status with foveal microstructure in repaired macular holes. Ophthalmologica. 2014;232(4):194–199. doi: 10.1159/000364883.
- Chang Y.-C., Liu P.-K., Kao T.-E., et al. Management of refractory large macular hole with autologous neurosensory retinal free flap trans. Retina. 2019 doi: 10.1097/IAE.0000000000002734.
- Kim S. H., Kim H. K., Yang J. Y., Lee S. C., Kim S. S. Visual recovery after macular hole surgery and related prognostic factors. Korean Journal of Ophthalmology. 2018;32(2):140–146. doi: 10.3341/kjo.2017.0085.
- Shinoda H., Shinoda K., Satofuka S., et al. Visual recovery after vitrectomy for macular hole using 25-gauge instruments. Acta Ophthalmologica. 2008;86(2):151–155. doi: 10.1111/j.1600-0420.2007.01000.x.
- Reibaldi M., Parravano M., Varano M., et al. Foveal microstructure and functional parameters in lamellar macular hole. American Journal of Ophthalmology. 2012;154(6):974–980. doi: 10.1016/j.ajo.2012.06.008.
- Cho J. H., Yi H. C., Bae S. H., Kim H. Foveal microvasculature features of surgically closed macular hole using optical coherence tomography angiography. BMC Ophthalmology. 2017;17:217. doi: 10.1186/s12886-017-0607-z.
- Kim Y. J., Jo J., Lee J. Y., Yoon Y. H., Kim J.-G. Macular capillary plexuses after macular hole surgery: an optical coherence tomography angiography study. British Journal of Ophthalmology. 2018;102(7):966–970. doi: 10.1136/bjophthalmol-2017-311132.
- Wilczyński T., Heinke A., Niedzielska-Krycia A., Jorg D., Michalska-Małecka K. Optical coherence tomography angiography features in patients with idiopathic full-thickness macular hole, before and after surgical treatment. Clinical Interventions in Aging. 2019;14:505–514. doi: 10.2147/CIA.S189417.
- Shahlaee A., Rahimy E., Hsu J., Gupta O. P., Ho A. C. Preoperative and postoperative features of macular holes on en face imaging and optical coherence tomography angiography. American Journal of Ophthalmology Case Reports. 2016;5:20–25.
- Sul S., Gurelik G., Korkmaz Ş., Ozsaygili C. Choroidal thickness in macular holes. International Ophthalmology. 2019;39(11):2595–2601. doi: 10.1007/s10792-019-01108-6.
- Pires J., Nadal J., Gomes N. L. Internal limiting membrane translocation for refractory macular holes. The British Journal of Ophthalmology. 2017;101(3):377–382. doi: 10.1136/bjophthalmol-2015-308299.
- Borowicz D., Nowomiejska K., Nowakowska D., et al. Functional and morphological results of treatment of macula-on and macula-off rhegmatogenous retinal detachment with pars plana vitrectomy and sulfur hexafluoride gas tamponade. BMC Ophthalmology. 2019;19(1):p. 118. doi: 10.1186/s12886-019-1120-3.
- Tarita-Nistor L., Gonza´lez E. G., Mandelcorn M. S., Lillakas L., Steinbach M. J. Fixation stability, fixation location, and visual acuity after successful macular hole surgery. Investigative Opthalmology & Visual Science. 2009;50(1):84–89. doi: 10.1167/iovs.08-2342.
- Sborgia G., Niro A., Sborgia A. Inverted internal limiting membrane-flap technique for large macular hole: a microperimetric study. International Journal of Retina and Vitreous. 2019;5(44) doi: 10.1186/s40942-019-0195-6.
- Bonnabel A., Bron A. M., Isaico R., Dugas B., Nicot F., Creuzot-Garcher C. Long-term anatomical and functional outcomes of idiopathic macular hole surgery: the yield of spectral-domain OCT combined with microperimetry. Graefe’s Archive for Clinical and Experimental Ophthalmology. 2013;251(11):2505–2511. doi: 10.1007/s00417-013-2339-y.
- Qi Y., Wang Z., Li S. M., et al. Effect of internal limiting membrane peeling on normal retinal function evaluated by microperimetry-3. BMC Ophthalmology. 2020;20(1) doi: 10.1186/s12886-020-01383-3.
- Laishram M., Srikanth K., Rajalakshmi A. R., Nagarajan S., Ezhumalai G. Microperimetry—a new tool for assessing retinal sensitivity in macular diseases. Journal of Clinical and Diagnostic Research. 2017;11(7):8–11.
- Leisser C., Palkovits S., Hirnschall N., et al. One-year results after internal limiting membrane flap transposition for surgical repair of macular holes with respect to microperimetry flap transposition for surgical repair of macular holes with respect to microperimetry. Ophthalmic Research. 2019;61(2):83–87. doi: 10.1159/000489458.
- Kunikata H., Yasuda M., Aizawa N., et al. Retinal sensitivity and vessel density after macular hole surgery with the superior inverted internal limiting membrane flap technique. Retina. 2020 doi: 10.1097/IAE.0000000000002839.
- Bacherini D., Savastano M. C., Dragotto F., et al. Morpho-functional evaluation of full-thickness macular holes by the integration of optical coherence tomography angiography and microperimetry. Journal of Clinical Medicine. 2020;9(1) doi: 10.3390/jcm9010229.
Source: PubMed