Evaluating the Validity of Current Mainstream Wearable Devices in Fitness Tracking Under Various Physical Activities: Comparative Study

Junqing Xie, Dong Wen, Lizhong Liang, Yuxi Jia, Li Gao, Jianbo Lei, Junqing Xie, Dong Wen, Lizhong Liang, Yuxi Jia, Li Gao, Jianbo Lei

Abstract

Background: Wearable devices have attracted much attention from the market in recent years for their fitness monitoring and other health-related metrics; however, the accuracy of fitness tracking results still plays a major role in health promotion.

Objective: The aim of this study was to evaluate the accuracy of a host of latest wearable devices in measuring fitness-related indicators under various seminatural activities.

Methods: A total of 44 healthy subjects were recruited, and each subject was asked to simultaneously wear 6 devices (Apple Watch 2, Samsung Gear S3, Jawbone Up3, Fitbit Surge, Huawei Talk Band B3, and Xiaomi Mi Band 2) and 2 smartphone apps (Dongdong and Ledongli) to measure five major health indicators (heart rate, number of steps, distance, energy consumption, and sleep duration) under various activity states (resting, walking, running, cycling, and sleeping), which were then compared with the gold standard (manual measurements of the heart rate, number of steps, distance, and sleep, and energy consumption through oxygen consumption) and calculated to determine their respective mean absolute percentage errors (MAPEs).

Results: Wearable devices had a rather high measurement accuracy with respect to heart rate, number of steps, distance, and sleep duration, with a MAPE of approximately 0.10, whereas poor measurement accuracy was observed for energy consumption (calories), indicated by a MAPE of up to 0.44. The measurements varied for the same indicator measured by different fitness trackers. The variation in measurement of the number of steps was the highest (Apple Watch 2: 0.42; Dongdong: 0.01), whereas it was the lowest for heart rate (Samsung Gear S3: 0.34; Xiaomi Mi Band 2: 0.12). Measurements differed insignificantly for the same indicator measured under different states of activity; the MAPE of distance and energy measurements were in the range of 0.08 to 0.17 and 0.41 to 0.48, respectively. Overall, the Samsung Gear S3 performed the best for the measurement of heart rate under the resting state (MAPE of 0.04), whereas Dongdong performed the best for the measurement of the number of steps under the walking state (MAPE of 0.01). Fitbit Surge performed the best for distance measurement under the cycling state (MAPE of 0.04), and Huawei Talk Band B3 performed the best for energy consumption measurement under the walking state (MAPE of 0.17).

Conclusions: At present, mainstream devices are able to reliably measure heart rate, number of steps, distance, and sleep duration, which can be used as effective health evaluation indicators, but the measurement accuracy of energy consumption is still inadequate. Fitness trackers of different brands vary with regard to measurement of indicators and are all affected by the activity state, which indicates that manufacturers of fitness trackers need to improve their algorithms for different activity states.

Keywords: data accuracy; fitness trackers; physical activity; wearable electronic devices.

Conflict of interest statement

Conflicts of Interest: None declared.

©Junqing Xie, Dong Wen, Lizhong Liang, Yuxi Jia, Li Gao, Jianbo Lei. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 12.04.2018.

Figures

Figure 1
Figure 1
Comprehensive accuracies of indicators by different wearable devices. S=steps, D=distance, and C=calorie.
Figure 2
Figure 2
Distance accuracy for different devices used during three different physical activities.
Figure 3
Figure 3
Calorie accuracy for different devices used during three different physical activities.

References

    1. Abedtash H, Holden RJ. Systematic review of the effectiveness of health-related behavioral interventions using portable activity sensing devices (PASDs) J Am Med Inform Assoc. 2017 Sep 1;24(5):1002–13. doi: 10.1093/jamia/ocx006.
    1. Hardman AE, Stensel DJ. Physical Activity and Health: The Evidence Explained. Abingdon, United Kingdom: Routledge; 2009.
    1. Global Recommendations on Physical Activity for Health. Geneva: WHO Press, World Health Organization; 2010.
    1. Stateofobesity. [2018-02-13]. Physical Inactivity in the United States
    1. . 2014. [2018-03-31]. Global status report on noncommunicable diseases 2014 .
    1. Ridgers ND, McNarry MA, Mackintosh KA. Feasibility and effectiveness of using wearable activity trackers in youth: a systematic review. JMIR Mhealth Uhealth. 2016;4(4):e129.
    1. Bietz MJ, Bloss CS, Calvert S, Godino JG, Gregory J, Claffey MP, Sheehan J, Patrick K. Opportunities and challenges in the use of personal health data for health research. J Am Med Inform Assoc. 2016 Apr;23(e1):e42–8. doi: 10.1093/jamia/ocv118.
    1. Bravata DM, Smith-Spangler C, Sundaram V, Gienger AL, Lin N, Lewis R, Stave CD, Olkin I, Sirard JR. Using pedometers to increase physical activity and improve health: a systematic review. J Am Med Assoc. 2007;298(19):2296–304.
    1. Poirier J, Bennett WL, Jerome GJ, Shah NG, Lazo M, Yeh HC, Clark JM, Cobb NK. Effectiveness of an activity tracker- and internet-based adaptive walking program for adults: a randomized controlled trial. J Med Internet Res. 2016;18(2):e34.
    1. Gualtieri L, Rosenbluth S, Phillips J. Can a free wearable activity tracker change behavior? The impact of trackers on adults in a physician-led wellness group. JMIR Res Protoc. 2016 Nov 30;5(4):e237. doi: 10.2196/resprot.6534.
    1. Abedtash H, Holden RJ. Systematic review of the effectiveness of health-related behavioral interventions using portable activity sensing devices (PASDs) J Am Med Inform Assoc. 2017 Sep 1;24(5):1002–13. doi: 10.1093/jamia/ocx006.
    1. Sullivan AN, Lachman ME. Behavior change with fitness technology in sedentary adults: a review of the evidence for increasing physical activity. Front Public Health. 2016;4:289. doi: 10.3389/fpubh.2016.00289.
    1. Wen D, Zhang X, Lei J. Consumers' perceived attitudes to wearable devices in health monitoring in China: a survey study. Comput Methods Programs Biomed. 2017 Mar;140:131–7. doi: 10.1016/j.cmpb.2016.12.009.
    1. Evenson KR, Goto MM, Furberg RD. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int J Behav Nutr Phys Act. 2015 Dec 18;12:159. doi: 10.1186/s12966-015-0314-1.
    1. Desilets PA, Mahar MT. Evaluation of the Basis Band Fitness Tracker. Int J Exerc Sci. 2016;9(3):258–69.
    1. Dooley EE, Golaszewski NM, Bartholomew JB. Estimating accuracy at exercise intensities: a comparative study of self-monitoring heart rate and physical activity wearable devices. JMIR Mhealth Uhealth. 2017;5(3):e34. doi: 10.2196/mhealth.7043.
    1. Bai Y, Welk GJ, Nam YH, Lee JA, Lee JM, Kim Y, Meier NF, Dixon PM. Comparison of consumer and research monitors under semistructured settings. Med Sci Sports Exerc. 2016 Jan;48(1):151–8. doi: 10.1249/MSS.0000000000000727.
    1. World.taobao. [2018-02-13]. Lynx Poly cost Taobao headlines [In Chinese]
    1. Global.jd. [2018-02-13]. Worldwide sales
    1. Zol. [2018-02-13]. Today's focus [In Chinese] .
    1. Dongdong. [2018-03-02]. Move For better every day [In Chinese] .
    1. . [2018-03-02]. Music Power · Fall in love with your own good body [In Chinese] .
    1. Cosmed. [2018-02-13]. Cardiopulmonary Exercise
    1. Stahl SE, An HS, Dinkel DM, Noble JM, Lee JM. How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough? BMJ Open Sport Exerc Med. 2016;2(1):e000106. doi: 10.1136/bmjsem-2015-000106.
    1. Jo E, Lewis K, Directo D, Kim MJ, Dolezal BA. Validation of biofeedback wearables for photoplethysmographic heart rate tracking. J Sports Sci Med. 2016 Sep 5;15(3):540–7.
    1. Parak J, Korhonen I. Evaluation of wearable consumer heart rate monitors based on photopletysmography. 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society; 26-30 Aug 2014; Chicago, IL, USA. 2014.
    1. An HS, Jones GC, Kang SK, Welk GJ, Lee JM. How valid are wearable physical activity trackers for measuring steps? Eur J Sport Sci. 2017 Apr;17(3):360–8. doi: 10.1080/17461391.2016.1255261.
    1. Nelson MB, Kaminsky LA, Dickin DC, Montoye AH. Validity of consumer-based physical activity monitors for specific activity types. Med Sci Sports Exerc. 2016;48(8):1619–28. doi: 10.1249/MSS.0000000000000933.
    1. Tully MA, McBride C, Heron L, Hunter RF. The validation of Fibit Zip™ physical activity monitor as a measure of free-living physical activity. BMC Res Notes. 2014 Dec 23;7:952. doi: 10.1186/1756-0500-7-952.
    1. Takacs J, Pollock CL, Guenther JR, Bahar M, Napier C, Hunt MA. Validation of the Fitbit One activity monitor device during treadmill walking. J Sci Med Sport. 2014 Sep;17(5):496–500. doi: 10.1016/j.jsams.2013.10.241.
    1. Adam NJ, Spierer DK, Gu J, Bronner S. Comparison of steps and energy expenditure assessment in adults of fitbit tracker and ultra to the actical and indirect calorimetry. J Med Eng Technol. 2013 Oct;37(7):456–62. doi: 10.3109/03091902.2013.831135.
    1. Calabró MA, Stewart JM, Welk GJ. Validation of pattern-recognition monitors in children using doubly labeled water. Med Sci Sports Exerc. 2013 Jul;45(7):1313–22. doi: 10.1249/MSS.0b013e31828579c3.
    1. Sirard JR, Masteller B, Freedson PS, Mendoza A, Hickey A. Youth oriented activity trackers: comprehensive laboratory- and field-based validation. J Med Internet Res. 2017 Jul 19;19(7):e250. doi: 10.2196/jmir.6360.
    1. Lee JM, Kim Y, Welk GJ. Validity of consumer-based physical activity monitors. Med Sci Sports Exerc. 2014;46(9):1840–8. doi: 10.1249/MSS.0000000000000287.
    1. Bonomi AG, Plasqui G, Goris AH, Westerterp KR. Estimation of free-living energy expenditure using a novel activity monitor designed to minimize obtrusiveness. Obesity (Silver Spring) 2010 Sep;18(9):1845–51. doi: 10.1038/oby.2010.34. doi: 10.1038/oby.2010.34.
    1. Dannecker KL, Sazonova NA, Melanson EL, Sazonov ES, Browning RC. A comparison of energy expenditure estimation of several physical activity monitors. Med Sci Sports Exerc. 2013 Nov;45(11):2105–12. doi: 10.1249/MSS.0b013e318299d2eb.
    1. Drenowatz C, Eisenmann JC. Validation of the SenseWear Armband at high intensity exercise. Eur J Appl Physiol. 2011 May;111(5):883–7. doi: 10.1007/s00421-010-1695-0.
    1. Montgomery-Downs HE, Insana SP, Bond JA. Movement toward a novel activity monitoring device. Sleep Breath. 2012 Sep;16(3):913–7. doi: 10.1007/s11325-011-0585-y.
    1. Meltzer LJ, Hiruma LS, Avis K, Montgomery-Downs H, Valentin J. Comparison of a commercial accelerometer with polysomnography and actigraphy in children and adolescents. Sleep. 2015 Aug 1;38(8):1323–30. doi: 10.5665/sleep.4918.

Source: PubMed