A randomized trial to determine the minimum effective lidocaine volume for median nerve block using hydrodissection

Eric Dufour, Souhail Jaziri, Marie Alice Novillo, Lila Aubert, Anne Chambon, Rainer Kutz, Alexandre Vallée, Marc Fischler, Eric Dufour, Souhail Jaziri, Marie Alice Novillo, Lila Aubert, Anne Chambon, Rainer Kutz, Alexandre Vallée, Marc Fischler

Abstract

Ultrasound-guided hydrodissection with 5% dextrose in water (DW5) creates a peri-nervous compartment, separating the nerve from the neighboring anatomical structures. The aim of this randomized study was to determine the minimum volume of lidocaine 2% with epinephrine 1:200,000 required when using this technique to achieve an effective median nerve block at the elbow in 95% of patients (MEAV95). Fifty-two patients scheduled for elective hand surgery received an ultrasound-guided circumferential perineural injection of 4 ml DW5 and an injection of local anesthetic (LA) following a biased coin up-and-down sequential allocation method. A successful block was defined as a light touch completely suppressed on the two distal phalanges of the index finger within a 30-min evaluation period. The MEAV95 of lidocaine 2% with epinephrine was 4 ml [IQR 3.5-4.0]. Successful median nerve block was obtained in 38 cases (82.6%) with median onset time of 20.0 [10.0-21.2] minutes (95% CI 15-20). The analgesia duration was 248 [208-286] minutes (95% CI 222-276). Using an ultrasound-guided hydrodissection technique with DW5, the MEAV95 to block the median nerve at the elbow with 2% lidocaine with epinephrine was 4 ml [IQR 3.5-4.0]. This volume is close to that usually recommended in clinical practice.Trial registration clinicaltrials.gov. NCT02438657, Date of registration: May 8, 2015.

Conflict of interest statement

The authors declare no competing interests.

© 2022. The Author(s).

Figures

Figure 1
Figure 1
Flow chart.
Figure 2
Figure 2
Repartition of onset time for successful block according to the sensory and motor test results.
Figure 3
Figure 3
Relation between LA volume and block onset time for successful blocks. A successful block was defined by a score = 2 with a light touch felt on the P2 or P3 of the index finger.
Figure 4
Figure 4
Up-and-down evolution for median nerve block in patients receiving an ultrasound-guided median nerve block using hydrodissection with DW5 and 2% lidocaine with epinephrine.

References

    1. Gitman M, Barrington MJ. Local anesthetic systemic toxicity: A review of recent case reports and registries. Reg. Anesth. Pain Med. 2018;43:124–130.
    1. Neal JM, et al. The third american society of regional anesthesia and pain medicine practice advisory on local anesthetic systemic toxicity: Executive summary. Reg. Anesth. Pain Med. 2018;43:113–123. doi: 10.1097/AAP.0000000000000720.
    1. Eichenberger U, et al. Minimal local anesthetic volume for peripheral nerve block: A new ultrasound-guided, nerve dimension-based method. Reg. Anesth. Pain Med. 2009;34:242–246. doi: 10.1097/AAP.0b013e31819a7225.
    1. O'Donnell BD, Iohom G. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block. Anesthesiology. 2009;111:25–29. doi: 10.1097/ALN.0b013e3181a915c7.
    1. Ponrouch M, et al. Estimation and pharmacodynamic consequences of the minimum effective anesthetic volumes for median and ulnar nerve blocks: A randomized, double-blind, controlled comparison between ultrasound and nerve stimulation guidance. Anesth. Analg. 2010;111:1059–1064. doi: 10.1213/ANE.0b013e3181eb6372.
    1. Hadzic A, Dewaele S, Gandhi K, Santos A. Volume and dose of local anesthetic necessary to block the axillary brachial plexus using ultrasound guidance. Anesthesiology. 2009;111:8–9. doi: 10.1097/ALN.0b013e3181a913cc.
    1. Dufour E, et al. An ultrasonographic assessment of nerve stimulation-guided median nerve block at the elbow: A local anesthetic spread, nerve size, and clinical efficacy study. Anesth. Analg. 2010;111:561–567. doi: 10.1213/ANE.0b013e3181e3a06f.
    1. Cappelleri G, et al. Effects of the intraneural and subparaneural ultrasound-guided popliteal sciatic nerve block: A prospective, randomized, double-blind clinical and electrophysiological comparison. Reg. Anesth. Pain Med. 2016;41:430–437. doi: 10.1097/AAP.0000000000000413.
    1. Cappelleri G, et al. Intraneural ultrasound-guided sciatic nerve block: Minimum effective volume and electrophysiologic effects. Anesthesiology. 2018;129:241–248. doi: 10.1097/ALN.0000000000002254.
    1. Dufour E, et al. Ultrasound-guided perineural circumferential median nerve block with and without prior dextrose 5% hydrodissection: A prospective randomized double-blinded noninferiority trial. Anesth. Analg. 2012;115:728–733. doi: 10.1213/ANE.0b013e31825fa37d.
    1. Oron, A. P. Stationary and convergence properties of ’Up-and-Down’ methods. . (2006). Accessed 26 May 2021
    1. Pace NL, Stylianou MP. Advances in and limitations of up-and-down methodology: A précis of clinical use, study design, and dose estimation in anesthesia research. Anesthesiology. 2007;107:144–152. doi: 10.1097/01.anes.0000267514.42592.2a.
    1. Krediet AC, Moayeri N, Bleys RL, Groen GJ. Intraneural or extraneural: Diagnostic accuracy of ultrasound assessment for localizing low-volume injection. Reg. Anesth. Pain Med. 2014;39:409–413. doi: 10.1097/AAP.0000000000000124.
    1. Marhofer P, et al. Ultrasonographic guided axillary plexus blocks with low volumes of local anaesthetics: A crossover volunteer study. Anaesthesia. 2010;65:266–271. doi: 10.1111/j.1365-2044.2010.06247.x.
    1. Chin KJ, Perlas A, Chan VW, Brull R. Needle visualization in ultrasound-guided regional anesthesia: Challenges and solutions. Reg. Anesth. Pain Med. 2008;33:532–544.
    1. Karmakar MK, Shariat AN, Pangthipampai P, Chen J. High-definition ultrasound imaging defines the paraneural sheath and the fascial compartments surrounding the sciatic nerve at the popliteal fossa. Reg. Anesth. Pain Med. 2013;38:447–451. doi: 10.1097/AAP.0b013e31829ffcb4.
    1. Abdallah FW, Macfarlane AJ, Brull R. The requisites of needle-to-nerve proximity for ultrasound-guided regional anesthesia: A scoping review of the evidence. Reg. Anesth. Pain Med. 2016;41:221–228. doi: 10.1097/AAP.0000000000000201.
    1. Capek A, Dolan J. Ultrasound-guided peripheral nerve blocks of the upper limb. BJA Educ. 2015;15:160–165. doi: 10.1093/bjaceaccp/mku048.
    1. Moayeri N, Bigeleisen PE, Groen GJ. Quantitative architecture of the brachial plexus and surrounding compartments, and their possible significance for plexus blocks. Anesthesiology. 2008;108:299–304. doi: 10.1097/01.anes.0000299433.25179.70.
    1. Abdallah FW, Chan VW. The paraneural compartment: A new destination? Reg. Anesth. Pain Med. 2013;38:375–377. doi: 10.1097/AAP.0b013e3182a34dfa.
    1. Boezaart A, Sala-Blanch X, Monzo E, Reina MA. Our best anesthetic blocks are probably related to unintentional and unnoticed intraneural injection. Reg. Anesth. Pain Med. 2019;44:279–280. doi: 10.1136/rapm-2018-100087.
    1. Sotthisopha T, et al. Minimum effective volume of lidocaine for ultrasound-guided costoclavicular block. Reg. Anesth. Pain Med. 2017;42:571–574. doi: 10.1097/AAP.0000000000000629.
    1. Tran DQ, Dugani S, Dyachenko A, Correa JA, Finlayson RJ. Minimum effective volume of lidocaine for ultrasound-guided infraclavicular block. Reg. Anesth. Pain Med. 2011;36:190–194. doi: 10.1097/AAP.0b013e31820d4266.
    1. Saranteas T, Finlayson RJ, Tran DQ. Dose-finding methodology for peripheral nerve blocks. Reg. Anesth. Pain Med. 2014;39:550–555. doi: 10.1097/AAP.0000000000000157.
    1. Neal JM, et al. The second American Society of regional anesthesia and pain medicine evidence-based medicine assessment of ultrasound-guided regional anesthesia: Executive summary. Reg. Anesth. Pain Med. 2016;41:181–194. doi: 10.1097/AAP.0000000000000331.
    1. Tsui BC, Kropelin B. The electrophysiological effect of dextrose 5% in water on single-shot peripheral nerve stimulation. Anesth. Analg. 2005;100:1837–1839. doi: 10.1213/01.ANE.0000153020.84780.A5.