Five times sit-to-stand test performance in Parkinson's disease

Ryan P Duncan, Abigail L Leddy, Gammon M Earhart, Ryan P Duncan, Abigail L Leddy, Gammon M Earhart

Abstract

Objectives: To (1) determine intrarater and test-retest reliability of the Five times sit-to-stand test (FTSTS) in Parkinson's disease (PD), (2) characterize FTSTS performance in PD at different disease stages, (3) determine predictors of FTSTS performance in PD, and (4) determine the utility of the FTSTS for discriminating between fallers and nonfallers with PD, identifying an appropriate cutoff score to delineate between these groups.

Design: Measurement study of community-dwelling individuals with idiopathic PD.

Setting: A medical school laboratory.

Participants: Participants (N=82) were recruited via population-based sampling. The final sample included 80 participants. Two were excluded because of exclusion criteria and an unrelated illness, respectively.

Interventions: Not applicable.

Main outcome measures: FTSTS time (seconds) was the primary outcome measure. Secondary outcome measures included the Mini-Balance Evaluation Systems Test (Mini-BEST), Maximal Voluntary Isometric Contraction-Quadriceps, 9-Hole Peg Test (9HPT), 6-minute walk, Freezing of Gait Questionnaire, Activities-Specific Balance Confidence Scale, Physical Activity Scale for the Elderly, Parkinson's Disease Questionnaire-39, and Movement Disorders Society-Unified Parkinson's Disease Rating Scale.

Results: Interrater and test-retest reliability for the FTSTS were high (intraclass correlation coefficients: .99 and .76, respectively). Mean FTSTS performance was 20.25 ± 14.12 seconds. All mobility measures were significantly correlated with FTSTS (P<.01). The Mini-BEST and 9HPT together explained 53% of the variance in FTSTS. Receiver operating characteristic analysis determined a cutoff of 16.0 seconds (sensitivity, .75; specificity, .68) for discriminating between fallers and nonfallers, with an area under the curve of .77.

Conclusions: The FTSTS is a quick, easily administered measure that is useful for gross determination of fall risk in individuals with PD.

Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

Figures

Figure 1
Figure 1
ROC curve for the FTSTS showing sensitivity and specificity for discriminating between individuals with PD with and without a history of falls. Asterisk denotes cutoff score of 16 seconds (sensitivity = .75, specificity = .68).

References

    1. Fahn S. Description of Parkinson’s disease as a clinical syndrome. Annals of the New York Academy of Sciences. 2003;991:1–14.
    1. Kakinuma S, Nogaki H, Pramanik B, Morimatsu M. Muscle weakness in Parkinson’s disease: isokinetic study of the lower limbs. Eur Neurol. 1998;39:218–222.
    1. Allen NE, Sherrington C, Canning CG, Fung VS. Reduced muscle power is associated with slower walking velocity and falls in people with Parkinson’s disease. Park Rel Disord. 2010;16:261–4.
    1. Rudzinska M, Bukowczan S, Banaszkiewicz K, Stozek J, Zajdel K, Szczudlik A. Causes and risk factors of falls in patients with Parkinson’s disease. Neurologia I Neurochirurgia Polska. 2008;42:216–222.
    1. Lamberti P, Armenise S, Castaldo V, de Mari M, Iliceto G, Tronci P, Serlenga L. Freezing gait in Parkinson’s disease. Eur Neurol. 1997;38:297–301.
    1. Giladi N, Treves TA, Simon ES, Shabtai H, Orlov Y, Kandinov B, et al. Freezing of gait in patients with advanced Parkinson’s disease. J Neural Transm. 2001;108:53–61.
    1. Pickering RM, Grimbergen YA, Rigney U, Ashburn A, Mazibrada G, Wood B, et al. A meta-analysis of six prospective studies of falling in Parkinson’s disease. Mov Disord. 2007;22:1892–1900.
    1. Csuka M, McCarty DJ. Simple method for measurement of lower extremity muscle strength. The American Journal of Medicine. 1985;78:77–81.
    1. Bohannon RW. Sit-to-stand test for measuring performance of lower extremity muscles. Percept Mot Skills. 1995;80:163–6.
    1. Inkster LM, Eng JJ, MacIntyre DL, Stoessl AJ. Leg muscle strength is reduced in Parkinson’s disease and relates to the ability to rise from a chair. Mov Disord. 2003;18:157–162.
    1. Lord SR, Murray SM, Chapman K, Munro B, Tiedemann A. Sit-to-stand performance depends on sensation, speed, balance, and psychological status in addition to strength in older people. J Gerontol A Biol Sci Med Sci. 2002;57:M539–543.
    1. Ng S. Balance ability, not muscle strength and exercise endurance, determines the performance of hemiparetic subjects on the timed sit-to-stand test. Am J Phys Med Rehab. 2010;89:497–504.
    1. Whitney SL, Wrisley DM, Marchetti GF, Gee MA, Redfern MS, Furman JM. Clinical measurement of sit-to-stand performance in people with balance disorders: validity of data for the five-times-sit-to-stand test. Phys Ther. 2005;85:1034–1045.
    1. Buatois S, Perret-Guillaume C, Gueguen R, Miget P, Vancon G, Perrin P, Benetos A. A simple clinical scale to stratify risk of recurrent falls in community-dwelling adults aged 65 years and older. Phys Ther. 2010;90:550–560.
    1. Mong Y, Teo TW, Ng SS. 5-repetition sit-to-stand test in subjects with chronic stroke: reliability and validity. Arch Phys Med Rehab. 2010;91:407–413.
    1. Guralnik JM, Simonsick EM, Ferrucci L, Glynn RJ, Berkman LF, Blazer DG, et al. A short physical performance battery assessing lower extremity function: association with self-reported disability and prediction of mortality and nursing home admission. J Gerontol. 1994;49:M85–94.
    1. Hoehn MM, Yahr MD. Parkinsonism: onset, progression and mortality. Neurology. 1967;17:427–442.
    1. Jankovic J, McDermott M, Carter J, Gauthier S, Goetz C, Golbe L, et al. Variable expression of Parkinson’s disease: a base-line analysis of the DATATOP cohort. Neurology. 1990;50:1529–1534.
    1. Franchignoni F, Horak F, Godi M, Nardone A, Giordano A. Using psychometric techniques to improve the Balance Evaluation Systems Test: the mini-BESTest. J Rehabil Med. 2010;42:323–331.
    1. Leddy AL, Crowner B, Earhart GM. Utility of the Mini-BESTest, BESTest, and BESTest sections for balance assessments in Parkinson disease. J Neurol Phys Ther. In press.
    1. Chandler J, Duncan P, Studenski S. Choosing the best strength measure in frail older persons: importance of task specificity. Muscle Nerve Suppl. 1997;5:S47–S51.
    1. McCarthy EK, Horvat MA, Holtsberg PA, Wisenbaker JM. Repeated chair stands as a measure of lower limb strength in sexagenarian women. J Gerontol A Biol Sci Med Sci. 2004;59:1207–1212.
    1. Steffen T, Seney M. Test-retest reliability and minimal detectable change on balance and ambulation tests, the 36-item short-form health survey, and the unified Parkinson disease rating scale in people with parkinsonism. Phys Ther. 2008;88:733–746.
    1. Falvo MJ, Earhart GM. Six-minute walk distance in persons with Parkinson’s disease: a hierarchical regression model. Arch Phys Med Rehabil. 2009;90:1004–8.
    1. Earhart GM. Park Rel Disord. submitted.
    1. Giladi N, Tal J, Azulay T, Rascol O, Brooks DJ, Melamed E, et al. Validation of the freezing of gait questionnaire in patients with Parkinson’s disease. Mov Disord. 2009;24:655–661.
    1. Powell LE, Myers AM. The Activities-specific Balance Confidence (ABC) Scale. J Gerontol A Biol Sci Med Sci. 1995;50A:M28–34.
    1. Washburn RA, Smith KW, Jette AM, Janney CA. The Physical Activity Scale for the Elderly (PASE): development and evaluation. J Clin Epidemiol. 1993;46:153–162.
    1. Shuit AJ, Schouten EG, Westerterp KR, Saris WH. Validity of the Physical Activity Scale for the Elderly (PASE): according to energy expenditure assessed by the doubly labeled water method. J Clin Epidemiol. 1997;50:541–6.
    1. Peto V, Jenkinson C, Fitzpatrick R, Greenhall R. The development and validation of a short measure of functioning and well being for individuals with Parkinson’s disease. Qual Life Res. 1995;4:241–8.
    1. Peto V, Jenkinson C, Fitzpatrick R. PDQ-39: a review of the development, validation and application of a Parkinson’s disease quality of life questionnaire and its associated measures. J Neurol. 1998;245 (Suppl 1):10–14.
    1. Hintze J. NCSS. NCSS, LLC. Kaysville, Utah: 2009. .
    1. Ostchega Y, Harris TB, Hirsch R, Parsons VL, Kington R, Katzoff M. Reliability and prevalence of physical performance examination assessing mobility and balance in older persons in the US: data from the Third National Health and Nutrition Examination Survey. J Am Geriatric Soc. 2000;48:1136–1141.
    1. Jette AM, Jette DU, Ng J, Plotkin DJ, Bach MA. Are performance-based measures sufficiently reliable for use in multicenter trials? Musculoskeletal Impairment (MSI) Study Group. J Gerontol A Biol Sci Med Sci. 1999;54:M3–6.
    1. Schaubert KL, Bohannon RW. Reliability and validity of three strength measures obtained from community-dwelling elderly persons. J Strength Cond Res. 2005;19:717–720.
    1. Bohannon RW, Shove ME, Barreca SR, Masters LM, Sigouin CS. Five-repetition sit-to-stand test performance by community-dwelling adults: A preliminary investigation of times, determinants, and relationship with self-reported physical performance. Isokinetics and Exercise Sci. 2007;15:77–81.
    1. Inkster LM, Eng JJ. Postural control during a sit-to-stand task in individuals with mild Parkinson’s disease. Exp Brain Res. 2004;154:33–8.
    1. Schenkman M, Hughes MA, Samsa G, Studenski S. The relative importance of strength and balance in chair rise by functionally impaired older individuals. J Am Geriatr Soc. 1996;44:1441–1446.
    1. Campbell AJ, Borrie MJ, Spears GF. Risk factors for falls in a community-based prospective study of people 70 years and older. J Gerontol. 1989;44:M112–7.
    1. Nevitt MC, Cummings SR, Kidd S, Black D. Risk factors for recurrent nonsyncopal falls. A prospective study. J Am Med Assoc. 1989;261:2663–2668.
    1. Buatois S, Miljkovic D, Manckoundia P, Gueguen R, Miget P, Vancon G, et al. Five times sit to stand test is a predictor of recurrent falls in healthy community-living subjects aged 65 and older. J Am Geriatr Soc. 2008;56:1575–7.
    1. Landers MR, Backlund A, Davenport J, Fortune J, Schuerman S, Altenburger P. Postural instability in idiopathic Parkinson’s disease: discriminating fallers from nonfallers based on standardized clinical measures. J Neurol Phys Ther. 2008;32:56–61.
    1. Kerr GK, Worringham CJ, Cole MH, Lacherez PF, Wood JM, Silburn PA. Predictors of future falls in Parkinson disease. Neurology. 2010;75:116–124.

Source: PubMed

3
Subskrybuj