LithoVue™: A new single-use digital flexible ureteroscope

Salvatore Butticè, Tarik Emre Sener, Christopher Netsch, Esteban Emiliani, Rosa Pappalardo, Carlo Magno, Salvatore Butticè, Tarik Emre Sener, Christopher Netsch, Esteban Emiliani, Rosa Pappalardo, Carlo Magno

No abstract available

Keywords: endourology; flexible ureteroscopy; innovation; technology; urinary stone.

Conflict of interest statement

The authors declare no conflicts of interest.

Figures

Figure 1
Figure 1
The new single use flexible ureteroscope: LithoVue™. A. The LithoVue™ external aspect in the hands of the surgeon and the LithoVue™ monitor can be seen at the back. B. Maximum deflection of the ureteroscope tip; 270° in both directions. C. Close view of the tip, it’s possible to appreciate the small diameter of 7.7 Fr.
Figure 2
Figure 2
External view of the LithoVue™. A. The tip at maximum deflection. B. External view of the device with the tip straight. C. External view of the device with the tip at maximum deflection.
Figure 3
Figure 3
Endoscopic view from the LithoVue™ demonstrating the digital image quality during upper urinary tract endoscopy. A. Kidney stone inside the caliceal system. B. Kidney stone and a green coated 272 μm laser fiber.
Figure 4
Figure 4
Endoscopic view from the LithoVue™ demonstrating the digital image quality during upper urinary tract endoscopy. A stenotic infundibulum and a small stone fragment can be seen.
Figure 5
Figure 5
Monitor station of the LithoVue™ at Tenon University Hospital.

References

    1. Ghani KR, Sammon JD, Karakiewicz PI, et al. Trends in surgery for upper urinary tract calculi in the USA using the Nationwide Inpatient Sample: 1999-2009. BJU Int. 2013;112:224–230.
    1. Shah K, Monga M, Knudsen B. Prospective Randomized Trial Comparing 2 Flexible Digital Ureteroscopes: ACMI/Olympus Invisio DUR-D and Olympus URF-V. Urology. 2015;85:1267–1271.
    1. Buttice S, Sener TE, Proietti S, et al. Temperature Changes Inside the Kidney: What Happens During Holmium:Yttrium-Aluminium-Garnet Laser Usage? J Endourol. 2016;30:574–579.
    1. Somani BK, Al-Qahtani SM, de Medina SD, Traxer O. Outcomes of flexible ureterorenoscopy and laser fragmentation for renal stones: comparison between digital and conventional ureteroscope. Urology. 2013;82:1017–1019.
    1. Rouprêt M, Babjuk M, Compérat E, et al. European guidelines on upper tract urothelial carcinomas: 2013 update. Eur Urol. 2013;63:1059–1071.
    1. Abraham JBA, Abdelshehid CS, Lee HJ, et al. Rapid Communication: Effects of Steris 1™ Sterilization and Cidex® Ortho-Phthalaldehyde High-Level Disinfection on Durability of New-Generation Flexible Ureteroscopes. J Endourol. 2007;21:985–992.
    1. Carey RI, Martin CJ, Knego JR. Prospective evaluation of refurbished flexible ureteroscope durability seen in a large public tertiary care center with multiple surgeons. Urology. 2014;84:42–45.
    1. Shin RH, Lipkin ME, Preminger GM. Disposable devices for RIRS: Where do we stand in 2013? What do we need in the future? World J Urol. 2015;33:241–246.
    1. Rutala WA, Weber DJ. Reprocessing semicritical items: Current issues and new technologies. Am J Infect Control. 2016;44:e53–62.
    1. Clemens JQ, Dowling R, Foley F, et al. Joint AUA/SUNA white paper on reprocessing of flexible cystoscopes. J Urol. 2010;184:2241–2245.
    1. Kaplan A, Neisius A, Radvak D, et al. 1031 Evaluation of a novel single use flexible ureteroscope. Eur Urol Suppl. 2016;3:e1031.
    1. Proietti S, Dragos L, Molina W, Doizi S, Giusti G, Traxer O. Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model. J Endourol. 2016;30:655–659.

Source: PubMed

3
Subskrybuj