- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT02319239
Prostate Cancer Stereotactic Radiotherapy (ESKO)
Development of Prostate Cancer Stereotactic Radiotherapy in Tampere Using Intra-fractional Movement Detector and Diffusion-weighted Magnetic Resonance Imaging.
Primary purpose of the study is to develop a stereotactic radiation treatment (RT) to prostate cancer which minimizes treatment related toxicity. Movement of the prostate during a radiation therapy will be monitored by temporary implanted electromagnetic transmitter. This data will be used to define prostate marginals (PTV) for stereotactic treatment. Radiation toxicity to rectum will be reduced by using a rectum fixation during a treatment.
Study group I (20 patients) will be treated 39 x 2 Gy and study group II (20 patients) with 20 x 3 Gy fractionation schedules. With the data collected from these groups treatment marginals to prostate will be defined and used to treat group III (40 patients) with 5 x 7.25 Gy.
Second purpose of this study is to assess if Diffusion-weighted magnetic resonance imaging could be used to evaluate radiation treatment response in intermediate prostate cancer. Androgen deprivation therapy is not allowed in this study.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
New local prostate cancer patients needing external radiotherapy are included into three radiation dose groups;
Group I will be treated normal dosing (39 x 2 Gy) and study group II with hypofractionated dosing (20 x 3 Gy) and group III extreme hypofractionated dosing. Primary goal is to develop safe and effective curative radiotherapy for these patients
Second aim is to study Diffusion-weighted magnetic resonance image (DW MRI) in radiation treatment response in intermediate prostate cancer.
Patients are followed by MRI, PSA, bone scans and quality of life questionaries.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Tampere, Finlândia, 33521
- Tampere University Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Biopsy-proven prostate Cancer
One or two risk factors for intermediate prostate cancer:
- Gleason score 7
- T2b-T2c
- PSA 10-20 microg/l
- No need for androgen deprivation therapy
- Eligible fo MRI
- Radical radiotherapy
Exclusion Criteria:
- Locally advanced or metastatic prostate cancer
- Previous radiotherapy to pelvic reason
- Other severe disease
- Previous cancer within 5 years
- Severe urinary symptoms at the start of the study (over 20)
- Wide cavity after transurethral resection of prostate (TURP)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Conventional fractionation
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 15/39 fractions.
DW-MRI at baseline, 3 months and 12 months.
|
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 15/39 fractions.
DW-MRI at baseline, 3 months and 12 months.
|
|
Experimental: hypofractionated
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 10/20 fractions.
DW-MRI at baseline, 3 months and 12 months.
|
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 10/20 fractions.
DW-MRI at baseline, 3 months and 12 months
|
|
Experimental: Stereotactic fractionation
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 5/5 fractions.
DW-MRI at baseline, 3 months and 12 months.
|
During a radiotherapy period the prostate movement will be monitored by temporary implanted electromagnetic detector.
Rectum fixation at 5/5 fractions.
DW-MRI at baseline, 3 months and 12 months
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
To determine whether the temporary implanted electromagnetic transmitter could be used to reduce treatment marginals in prostate cancer radiation therapy
Prazo: 1 to 3 months
|
Prostate specific antigen (PSA) recurrence
|
1 to 3 months
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Evaluation of DW-MRI to predict the outcome of prostate cancer radiation therapy
Prazo: 0 - 12 months
|
PSA recurrence
|
0 - 12 months
|
|
quality of life changes
Prazo: 1 to 3 months
|
questionaires
|
1 to 3 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Petri Reinikainen, Tampere Unviersity Hospital
Publicações e links úteis
Publicações Gerais
- Vanhanen A, Reinikainen P, Kapanen M. Radiation-induced prostate swelling during SBRT of the prostate. Acta Oncol. 2022 Jun;61(6):698-704. doi: 10.1080/0284186X.2022.2062682. Epub 2022 Apr 17.
- Vanhanen A, Poulsen P, Kapanen M. Dosimetric effect of intrafraction motion and different localization strategies in prostate SBRT. Phys Med. 2020 Jun 12;75:58-68. doi: 10.1016/j.ejmp.2020.06.010. Online ahead of print.
- Vanhanen A, Syren H, Kapanen M. Localization accuracy of two electromagnetic tracking systems in prostate cancer radiotherapy: A comparison with fiducial marker based kilovoltage imaging. Phys Med. 2018 Dec;56:10-18. doi: 10.1016/j.ejmp.2018.11.007. Epub 2018 Nov 16.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- ETL R14009
- R14009 (Outro identificador: TampereUH)
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .