- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT03470714
Effect of Kinesiotaping on Force Irradiation
The Determination of Relationship Between Kinesiotaping and Contralateral Force Irradiation
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Fourty healthy subjects with no history of neurological or recent musculoskeletal injury will participate the study.
Healthy subjects are arranged in two groups of stimulation: kinesiotaping group (kinesiotaping and force irradiation) and control group (only force irradiation). The electromyographic response of the resting arm (non-dominant) will be assessed during the dominant arm movement for all subjects. Additionally, in kinesiotaping group, kinesiotaping will be applied 24 hours before the experiment.
The electromyographic response of the resting arm will be assessed under three contraction type movement (isometric, eccentric and concentric contractions) The SEMG signals are analysed by using MATLAB®, suitable signal proccessing techniques (linear envelope, Root Mean Square etc) are chosed. The statistical analysis are done by using SPSS®, according to data distribution, "Independent Sample T Test" or "Mann-Whitney U Test" is utilized for comparing outcomes of control and KT groups.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Istanbul, Peru
- Bezmialem Vakıf University
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- To be right-handed-dominant
- To have normal or corrected vision
- To have no formal history of any resistance training.
Exclusion Criteria:
- To have history of neurological or recent musculoskeletal injury
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Kinesiotaping Group
The group in which kinesiotaping is applied to non-dominant biceps brachii muscle of participants before 24 hours the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
For kinesiotaping, the elbow positioned in 30°-45° flexion and kinesiotaping facilitation technique is applied origin to insertion of non-dominant biceps brachii muscle before 24 hours the experiment.
Outros nomes:
|
|
Comparador Ativo: Control group
The group in which the participants only perform the the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Prazo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Prazo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion.
Prazo: after inclusion
|
while the right elbow performs concentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion
Prazo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Prazo: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Prazo: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Measurement of the electromyographic activity of left biceps brachii muscle during left elbow maximum isometric flexion by using electromyography device.
Prazo: after inclusion
|
Electromyographic activity of left elbow maximum isometric flexion is used for normalizing force irradiation data of left biceps brachii muscle
|
after inclusion
|
|
Measurement of the electromyographic activity of left triceps brachii muscle during left elbow maximum isometric extension by using electromyography device.
Prazo: after inclusion
|
Electromyographic activity of left elbow maximum isometric extension is used for normalizing force irradiation data of left triceps brachii muscle
|
after inclusion
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Diretor de estudo: Aydın AKAN, Istanbul University
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- hdenizkulli
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Force Irradiation
-
University of Nove de JulhoAinda não está recrutandoBruxismo do sono | Bruxismo do Sono, Infância
-
Institut Cancerologie de l'OuestRescindidoMieloma Múltiplo em RecaídaFrança
-
Memorial Sloan Kettering Cancer CenterFred Hutchinson Cancer CenterConcluídoMetástases LeptomeníngeasEstados Unidos