- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT03470714
Effect of Kinesiotaping on Force Irradiation
The Determination of Relationship Between Kinesiotaping and Contralateral Force Irradiation
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Fourty healthy subjects with no history of neurological or recent musculoskeletal injury will participate the study.
Healthy subjects are arranged in two groups of stimulation: kinesiotaping group (kinesiotaping and force irradiation) and control group (only force irradiation). The electromyographic response of the resting arm (non-dominant) will be assessed during the dominant arm movement for all subjects. Additionally, in kinesiotaping group, kinesiotaping will be applied 24 hours before the experiment.
The electromyographic response of the resting arm will be assessed under three contraction type movement (isometric, eccentric and concentric contractions) The SEMG signals are analysed by using MATLAB®, suitable signal proccessing techniques (linear envelope, Root Mean Square etc) are chosed. The statistical analysis are done by using SPSS®, according to data distribution, "Independent Sample T Test" or "Mann-Whitney U Test" is utilized for comparing outcomes of control and KT groups.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Istanbul, Tacchino
- Bezmialem Vakıf University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- To be right-handed-dominant
- To have normal or corrected vision
- To have no formal history of any resistance training.
Exclusion Criteria:
- To have history of neurological or recent musculoskeletal injury
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Kinesiotaping Group
The group in which kinesiotaping is applied to non-dominant biceps brachii muscle of participants before 24 hours the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
For kinesiotaping, the elbow positioned in 30°-45° flexion and kinesiotaping facilitation technique is applied origin to insertion of non-dominant biceps brachii muscle before 24 hours the experiment.
Altri nomi:
|
|
Comparatore attivo: Control group
The group in which the participants only perform the the force irradiation experiment.
|
For the force irradiation, while the subjects perform dominant elbow flexion at an angular velocity of 60°/s for concentric contractions, 30°/s for eccentric contractions, at 90° elbow flexion position for isometric contractions with a maximal effort level, electrical activity of the non-dominant biceps brachii and triceps brachii muscles are recorded.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Lasso di tempo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs isometric elbow flexion
Lasso di tempo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion.
Lasso di tempo: after inclusion
|
while the right elbow performs concentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs concentric elbow flexion
Lasso di tempo: after inclusion
|
while the right elbow performs isometric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left biceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Lasso di tempo: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left biceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
|
Measurement of the surface electromyographic activity of left triceps brachii muscle by using surface electromyography device while the right elbow performs eccentric elbow flexion
Lasso di tempo: after inclusion
|
while the right elbow performs eccentric elbow flexion, electromyographic activity of left triceps brachii was determined by using surface electromyography device.
After signal processing and normalization, the electromyographic data of kinesiotaping and control groups will be compared.
|
after inclusion
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Measurement of the electromyographic activity of left biceps brachii muscle during left elbow maximum isometric flexion by using electromyography device.
Lasso di tempo: after inclusion
|
Electromyographic activity of left elbow maximum isometric flexion is used for normalizing force irradiation data of left biceps brachii muscle
|
after inclusion
|
|
Measurement of the electromyographic activity of left triceps brachii muscle during left elbow maximum isometric extension by using electromyography device.
Lasso di tempo: after inclusion
|
Electromyographic activity of left elbow maximum isometric extension is used for normalizing force irradiation data of left triceps brachii muscle
|
after inclusion
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Direttore dello studio: Aydın AKAN, Istanbul University
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- hdenizkulli
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Force Irradiation
-
Zimmer BiometTerminatoFrattura intracapsulare del femore prossimale | Frattura sottocapitata del collo del femore di I grado da giardino | Frattura sottocapitata del collo femorale di II grado GardenStati Uniti
-
Institut Cancerologie de l'OuestTerminatoMieloma multiplo in recidivaFrancia
-
Medical University of ViennaMedical University of GrazNon ancora reclutamentoGittata cardiaca | Misura emodinamica | Non invasivoAustria
-
Medical University of South CarolinaTerminato
-
Instituto Nacional de Cardiologia Ignacio ChavezSconosciuto
-
VA Office of Research and DevelopmentCompletato
-
Rabin Medical CenterOno Academic CollegeSconosciuto
-
Michael Lichtenberg, MDReclutamentoMalattia arteriosa periferica (PAD)Germania
-
C. R. BardCompletatoRegistro del mondo reale che valuta l'uso clinico del palloncino PTA a fuoco forzato Bard UltraScoreMalattie arteriose occlusive | Malattia arteriosa periferica | Malattie vascolari perifericheStati Uniti
-
Fundació Institut de Recerca de l'Hospital de la...CompletatoProgrammi per persone saneSpagna