- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07587138
Clinical Evaluation of a Novel Trifocal IOL
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
In this study, subjects with cataracts in both eyes will undergo cataract surgery and be implanted with trifocal IOLs. One eye will receive the investigational IOL Model LPYWT0 IOL, and the other eye will receive the commercially marketed Clareon PanOptix Pro IOL Model PXYWT0. The second eye surgery will occur 7-14 days after the first. Subjects will attend 9 planned study visits to include for an individual duration of participation of approximately 7 months.
This study is planned to be conducted in India and the Philippines.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Alcon Call Center
- Número de telefone: 1-888-451-3937
- E-mail: alcon.medinf@alcon.com
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Key Inclusion Criteria:
- The calculated power needed for the artificial lens (IOL) must be between +15.0 and +25.0 D in each eye, designed to bring subject vision as close to "0.0" (neutral) as possible, meaning they will not be strongly nearsighted or farsighted after surgery.
- Subjects must have low levels of astigmatism (misshapen cornea) in the eyes (less than 1.00 D).
- In the doctor's opinion, the subjects have the potential to achieve good vision (0.2 logMAR, which is roughly 20/32 Snellen or better) in each eye after the surgery, when wearing the best possible spectacles or contact lenses.
- Other protocol-specified inclusion criteria may apply.
Key Exclusion Criteria:
- Clinically significant corneal diseases which may, according to the investigator's medical opinion, adversely affect visual outcomes.
- Any ocular or systemic health condition or medical issue that, in the investigator's medical opinion, could make the study results unreliable, prevent the person from finishing the study, or increase their safety risk.
- People who want to have one eye set for distance vision and the other for near vision.
- The doctor expects significant blurry vision (astigmatism) after the procedure.
- Other protocol-specified exclusion criteria may apply.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Outro: LPYWT0 / PXYWT0
Investigational IOL Model LPYWT0 implanted in the first operative eye during cataract surgery with Clareon PanOptix Pro IOL Model PXYWT0 in the second eye, as randomized.
The second eye will be implanted 7-14 days after the first.
|
Removal of the cataractous lens by phacoemulsification followed by implantation of the IOL
Investigational blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Commercially available blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Outros nomes:
|
|
Outro: PXYWT0 / LPYWT0
Clareon PanOptix Pro IOL Model PXYWT0 implanted in the first operative eye during cataract surgery with investigational IOL Model LPYWT0 implanted in the second eye, as randomized.
The second eye will be implanted 7-14 days after the first.
|
Removal of the cataractous lens by phacoemulsification followed by implantation of the IOL
Investigational blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Commercially available blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Mean Monocular Photopic Best Corrected Distance Visual Acuity (BCDVA)
Prazo: Month 6 postoperative
|
Visual Acuity will be assessed using letter charts under well-lit (photopic) conditions with correction in place at a distance of 4 meters from the subject.
BCDVA will be recorded in logarithm minimum angle of resolution (logMAR) where 0.0 logMAR is equivalent to 20/20 Snellen, or normal distance eyesight, and negative logMAR values represent better-than-normal distance eyesight.
|
Month 6 postoperative
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Clinical Trial Lead, Surgical, Alcon Research, LLC
Publicações e links úteis
Links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- ILW559-C003
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .